SENSORTECHNICS SCC100D

SCC Series
Pressure sensors
FEATURES
GENERAL DESCRIPTION
·
0...5 to 0...100 psi
·
Low cost sensor element
·
Internal temperature
compensation
·
Differential, gage and
absolute
APPLICATIONS
·
Pneumatic controls
·
Automotive diagnostics
·
Medical equipment
·
Dental equipment
·
Environmental controls
EQUIVALENT CIRCUIT
The SCC series offer an extremely low
cost sensor element with a temperature
stable output when driven with a constant
current source. These integrated circuit
sensors were designed for extremely cost
sensitive applications where precise accuracy over a wide temperature range is not
required. This series is intended for use
with non-corrosive, non-ionic working fluids
such as air and dry gases.
Absolute devices have an internal vacuum
reference and an output voltage proportional to applied pressure. The differential devices allow application of pressure to either
side of the diaphragm and the devices are
thereby available to measure both differential and/or gage pressures.
Scale:
This product is packaged either in SenSym's
standard low cost chip carrier "button"
package, a plastic ported "N" package or a
dual inline package (DIP). All packages are
designed for applications where the
sensing element is to be integral to the OEM
equipment. These packages can be o-ring
1 cm
½ inch
sealed, epoxied, and/or clamped onto a
pressure fitting. A closed bridge
4-pin SIP configuration is provided for electrical connection to the button package. The
DIP package offer a 5-pin open bridge
configuration.
ELECTRICAL CONNECTION
Vs
GND
out +
+VS
out -
+
1
2
3
P1
4
Output
SCC..
button sensor
Button Sensor or "N" Package
+Vs
Vs
1
P2
+Vs 4
out +
out -
GND
GND
out -
out +
1
+Vs
P1
out +
GND
4
+Vs
out -
+Vs
1
P1
P2
4
+Vs
vent hole
-
SCCxxxGD2
DIP
SCCxxxAD2
DIP
SCCxxxD4
DIP
Output
+
DIP Package
July 2005 / 040
The polarity indicated is for pressure applied to
SCC.../SCC...N : P1 (forward gage)
SCC...GD2
: P2 (backward gage)
SCC...ASO/GSO : P1 (forward gage)
SCC...AD2
: P1 (forward gage)
SCC...DD4
: P2 (backward gage)
1/5
www.sensortechnics.com
SCC Series
Pressure sensors
PRESSURE SENSOR CHARACTERISTICS
Maximum ratings (for all devices)
Supply current, IS
1.5 mA
Temperature ranges
Compensated
Operating
Storage
0 to +50°C
-40 to +85°C
-55 to +125°C
Humidity
0 to 100 %RH
Lead temperature (soldering 4 sec.)
Common-mode pressure
250°C
150 psi
PERFORMANCE CHARACTERISTICS (individual models) IS = 1.0 mA, TA = 25°C1
Part number
SCC05(D,G)
SCC15A
SCC15(D,G)
SCC30A
SCC30(D,G)
SCC100A
SCC100(D,G)
Operating
pressure
range
Proof
pressure9
0 - 5 psid(g)
0 - 15 psia
0 - 15 psid(g)
0 - 30 psia
0 - 30 psid(g)
0 - 100 psia
0 - 100 psid(g)
20 psi
30 psia
30 psi
60 psia
60 psi
150 psia
150 psi
Accuracy2
0.50
0.50
0.50
0.50
0.50
0.50
0.50
%
%
%
%
%
%
%
Effect
on span3
(0 - 50°C)
1.50
1.50
1.50
1.50
1.50
1.50
1.50
Effect
on offset4
(0 - 50°C)
%
%
%
%
%
%
%
2.00
2.00
2.00
2.00
2.00
2.00
2.00
%
%
%
%
%
%
%
Full-scale
span1,5
(mV)
25 - 65
30 - 95
40 - 95
60 - 150
60 - 150
85 - 225
85 - 225
PERFORMANCE CHARACTERISTICS (all models) IS = 1.0 mA, TA = 25°C
Characteristics
Zero pressure offset
Combined linearity, hysteresis, repeatability2
Temperature effect on span3,8
Temperature effect on offset4,8
Long term stability of offset and span6
Response time (10 to 90 %)7
Input impedance
Output impedance
Min.
Typ.
Max.
Unit
-30.0
----------4.00
4.00
-10
0.25
0.25
0.50
0.10
0.10
5.00
5.00
20.0
0.50
1.50
2.00
----6.50
6.50
mV
%FSO
%FSO
%FSO
mV
ms
kΩ
kΩ
Specification notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
2/5
Reference conditions: supply current = 1.0 mA, TA=25°C, common-mode line pressure = 0 psig, pressure applied to P1, unless
otherwise noted.
Accuracy is the sum of hysteresis and linearity. Hysteresis is the maximum output difference at any point within the operating
pressure range for increasing and decreasing pressure. Linearity refers to the best straight line fit as measured for the
offset, full-scale and 1/2 full-scale pressure at 25°C.
This is the maximum temperature shift for span when measured between 0 and 50°C relative to the 25°C reading.
Typical temperature coefficients for span and resistance are -2200 and +2200 ppm/°C respectively.
This is the maximum temperature shift for offset when measured between 0 and 50°C relative to the 25°C reading.
Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Maximum difference in output at any pressure with the operating pressure range and temperature within 0 to 50°C after:
a) 100 temperature cycles, 0 to 50°C.
b) 1.0 million pressure cycles, 0 psi to full-scale span.
Response time for a 0 psi to full-scale span pressure step change. 10 to 90 % rise time.
Temp. effect on span and offset are guaranteed by design. Therefore these parameters are not 100 % tested.
If the proof pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
Note: The proof pressure for the forward gage of all devices in the D4-package is the specified value or 100 psi whatever is
less. The SCC100D (button package) can be used in forward gage mode only when the pressure doesn't exceed 30 psi,
or no special care ist taken.
July 2005 / 040
www.sensortechnics.com
SCC Series
Pressure sensors
PHYSICAL DIMENSIONS
Button package
mass: 1 g
dimensions in inches (mm)
Basic sensor DIP "D2" package
mass: 1 g
July 2005 / 040
dimensions in inches (mm)
3/5
www.sensortechnics.com
SCC Series
Pressure sensors
PHYSICAL DIMENSIONS (cont.)
Basic sensor DIP "D4" package
0.550
(13.97)
P1
0.050
typ.
(1.27)
P2
0.470
(11.94)
0.090 typ.
(2.29)
0.135
(3.43)
0.300
(7.62)
0.250
(6.35)
0.285
(7.24)
0.070
(1.78)
0.600
(15.24)
mass: 1 g
0.01
(0.25)
0.380
(9.65)
0.110 typ.
(2.79)
0.020 typ.
(0.51)
0.100 typ.
(2.54)
dimensions in inches (mm)
N package
mass: 5 g
4/5
dimensions in inches (mm)
July 2005 / 040
www.sensortechnics.com
SCC Series
Pressure sensors
ORDERING INFORMATION
Part number
Pressure range
Absolute
pressure
Button
p ackag e
" N " p ackag e
DIP package
single port
0...15 psi
S C C 15A
S C C 15A N
S C C 15A D 2
0...30 psi
S C C 30A
S C C 30A N
S C C 30A D 2
0...100 psi
S C C 100A
S C C 100A N
S C C 100A D 2
0...5 psi
Gage
pressure
0...15 psi
0...30 psi
SCC05GD2
use
differential
devices
use
differential
devices
0...100 psi
Differential
pressure
DIP package
dual port
SCC15GD2
SCC30GD2
SCC100GD2
0...5 psi
S C C 05D
S C C 05D N
S C C 05D D 4
0...15 psi
S C C 15D
S C C 15D N
S C C 15D D 4
0...30 psi
S C C 30D
S C C 30D N
S C C 30D D 4
0...100 psi
S C C 100D
S C C 100D N
S C C 100D D 4
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any
liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent
rights nor the rights of others.
July 2005 / 040
5/5
www.sensortechnics.com