SCC SERIES Pressure Sensors FEATURES GENERAL DESCRIPTION · 0 - 5 to 0 - 300 psi · Environmental Controls The SCC series offer an extremely low cost sensor element with a temperature stable output when driven with a constant current source. These integrated circuit sen-sors were designed for extremely cost sensitive applications where precise accuracy over a wide temperature range is not required. This series is intended for use with non-corrosive, non-ionic working fluids such as air and dry gases. Absolute devices have an internal vacuum reference and an output voltage proportional to applied pressure. The differential devices allow application of pressure to either side of the diaphragm and the devices are thereby available to measure both differential and/or gage pressures. This product is packaged either in SenSym´s standard low cost chip carrier "button" package, a plastic ported "N" package, a metal package or a dual inline package (DIP). All packages are designed for applications where the sensing element is to be integral to the OEM equipment. These packages can be O-ring sealed, epoxied, and/or clamped onto a pressure fitting. A closed bridge four-pin SIP configuration is EQUIVALENT CIRCUIT ELECTRICAL CONNECTIONS · Low Cost Sensor Element · Internal Temperature Compensation · Differential, Gage and Absolute APPLICATIONS · Pneumatic Controls · Automotive Diagnostics · Medical Equipment · Dental Equipment Scale: 1cm ½ inch provided for electrical connection to the button package. The TO can and the DIP offer a 5-pin open bridge configuration. GND 1 out + 2 +VS 3 out - 4 Vs SCC.. Button Sensor + TO Can (buttom view) Output Button Sensor or "N" Package +Vs +Vs 1 4 out + out - GND GND out - out + out + +Vs 1 GND 4 out - +Vs +Vs 1 P1 P2 4 vent hole SCCxxxGD2 DIP Vs SCCxxxAD2 DIP SCCxxxD4 DIP - The polarity indicated is for pressure applied to SCC.../SCC...N : P1 (forward gage) SCC...ASO/GSO : P1 (forward gage) SCC...DD4 : P2 (backward gage) SCC...GD2 SCC...AD2 : : P2 P1 (backward gage) (forward gage) Output + (Open Bridge) TO Can or DIP Package January 1998/040 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com +Vs SCC SERIES Pressure Sensors PRESSURE SENSOR CHARACTERISTICS Maximum Ratings (For All Devices) Supply Current, IS Temperature Ranges Compensated Operating Storage Humidity Lead Temperature (soldering 4 sec) Common-Mode Pressure 1.5 mA 0°C to +50°C -40°C to +85°C -55°C to +125°C 0 to 100 %RH 250°C 150 psi Performance Characteristics (Individual Models) IS = 1.0 mA, TA = 25°C1 Part Number SCC05(D,G) SCC15A SCC15(D,G) SCC30(A,D,G) SCC100A SCC100(D,G)9 SCC300A Operating Pressure Range Maximum Over Pressure 20 psi 30 psia 30 psi 60 psi 150 psia 150 psig 450 psia 0-5 psid(g) 0-15 psia 0-15 psid(g) 0-30 psid(g) 0-100 psia 0-100 psig 0-300 psia Accuracy2 Effect On Span3 (0°C-50°C) Effect On Offset4 (0°C-50°C) Full-Scale Span5 (mV) 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 1.50% 1.50% 1.50% 1.50% 1.50% 1.50% 1.50% 2.00% 2.00% 2.00% 2.00% 2.00% 2.00% 2.00% 25-65 30-95 40-95 60-150 85-225 85-225 50-120 Performance Characteristics (All Models) IS = 1.0 mA, TA = 25°C Characteristics Zero Pressure Offset Combined, Linearity, Hysteresis, Repeatability2 Temperature Effect on Span3, 8 Temperature Effect on Offset4,8 Long Term Stability of Offset and Span6 Response Time (10% to 90%)7 Input Impedance Output Impedance Min. Typ. Max. Unit -30.0 ----------4.00 4.00 -10 0.25 0.25 0.50 0.10 0.10 5.00 5.00 20.0 0.50 1.50 2.00 ----6.50 6.50 mV %FSO %FSO %FSO %FSO mSec kΩ kΩ Specification Notes: 1: 2: 3: 4: 5: 6: 7: 8: 9: Reference Conditions: Supply Current = 1.0 mA, TA=25°C, Common-mode Line Pressure = 0 psig, Pressure Applied to P1, unless otherwise noted. Accuracy is the sum of Hysterisis and Linearity. Hysterisis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Linearity refers to the best straight line fit as measured for the offset, full-scale and 1/2 full-scale pressure at 25°C. This is the maximum temperature shift for span when measured between 0°C and 50°C relative to the 25°C reading. Typical temperature coefficients for span and resistance are -2200 ppm/°C and +2200 ppm/°C respectively. This is the maximum temperature shift for offset when measured between 0°C and 50°C relative to the 25°C reading. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Maximum difference in output at any pressure with the operating pressure range and temperature within 0°C to 50°C after: a) 100 temperature cycles, 0°C to 50°C b) 1.0 million pressure cycles, 0 psi to full-scale span Response time for a 0 psi to full-scale span pressure step change. 10% to 90% rise time Temp effect on span and offset are guaranteed by design. Therefore these parameters are not 100% tested. The SCC100D devices can only be used in a forward gauge mode. Application of more than 30 psig to the back side of any of the SCC Series devices can result in device failure. January 1998/040 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com SCC SERIES Pressure Sensors PHYSICAL DIMENSIONS Button Package Basic Sensor DIP "D2" Package January 1998/040 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com SCC SERIES Pressure Sensors PHYSICAL DIMENSIONS (cont.) Basic Sensor DIP "D4" Package N Package January 1998/040 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com SCC SERIES Pressure Sensors PHYSICAL DIMENSIONS (cont.) AHO Package (TO-5) GSO Package (TO-39) ORDERING INFORMATION Pressure Range Absolute Pressure 0 - 15 psi 0 - 30 psi 0 - 100 psi 0 - 300 psi Gage Pressure 0 - 5 psi 0 - 15 psi 0 - 30 psi 0 - 100 psi Differential Pressure 0 - 5 psi 0 - 15 psi 0 - 30 psi 0 - 100 psi(9) Order Part Number TO Package DIP Package single port Button Package "N" Package DIP Package Dual port SCC15A SCC30A SCC100A --- SCC15AN SCC30AN SCC100AN --- SCC15AHO SCC30AHO SCC100AHO SCC300AHO SCC15AD2 SCC30AD2 SCC100AD2 --------- use differential devices use differential devices SCC05GSO SCC15GSO SCC30GSO --- SCC05GD2 SCC15GD2 SCC30GD2 --- --------- SCC05D SCC15D SCC30D SCC100D SCC05DN SCC15DN SCC30DN SCC100DN --------- --------- SCC05DD4 SCC15DD4 SCC30DD4 SCC100DD4 SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. January 1998/040 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com