AD2C541 1 Form A Solid State Relay DESCRIPTION The AD2C541 is a bi-directional, single-pole, single-throw, normally open high power solid-state relay. The relay consists of IR LED optically coupled to an IC that drives two rugged source-to-source low on-resistance enhancement type DMOS transistors. With high load current rating (500mA), high isolation (5kV) and compact package size, the AD2C541 is ideally suited to high power applications where board space is at a premium. FEATURES APPLICATIONS • Low On-Resistance (1 ohm MAX) • Reed relay replacement • High Load Current (500mA) • Meter reading systems • Small package outline (4DIP) - reduces board space • Medical equipment • High input-to-output Isolation (5kV) • Battery monitoring • Low input control power consumption (2.5mA TYP) • Multiplexers • Long life / Solid State reliability OPTIONS/SUFFIXES* ABSOLUTE MAXIMUM RATINGS* • -S Surface Mount leadform option (65 pcs / tube) • -TR Tape & Reel option (2,000 pcs / reel) • -V VDE0884 compliant lead spacing (0.4" / 10.16mm) NOTE: Suffixes listed above are not included in marking on device for part number identification. SCHEMATIC DIAGRAM PARAMETER UNIT MIN Storage Temperature °C -40 150 Operating Temperature °C -40 85 Continuous Input Current mA 50 Transient Input Current (1us) mA 400 Reverse Input Control Voltage V 5 mW 500 Output Power Dissipation + INPUT 1 2 - INPUT 4 LOAD 3 LOAD TYP MAX *The values indicated are absolute stress ratings. Functional operation of the device is not implied at these or any conditions in excess of those defined in electrical characteristics section of this document. Exposure to Absolute Ratings may cause permanent damage to the device and may adversely affect reliability. APPROVALS • UL/C-UL Approved: File E201932 © 2008 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 Page 1 of 5 AD2C541 rev 1.42 (5/15/2008) AD2C541 1 Form A Solid State Relay ELECTRICAL CHARACTERISTICS - 25°C PARAMETER UNIT MIN TYP MAX 1.2 1.5 TEST CONDITIONS INPUT SPECIFICATIONS LED Forward Voltage V LED Reverse Voltage 6 12 V Turn-On Current mA 2.5 Turn-Off Current mA 0.5 If = 10mA Ir = 10uA 5 Io = 500mA OUTPUT SPECIFICATIONS Blocking Voltage V Continuous Load Current mA On-Resistance Leakage Current Output Capacitance Offset Voltage 60 Io = 1uA 500 If = 5mA Ω 0.7 1 Io = 500mA µA 0.07 1 Vo = 60V pF 125 200 Vo = 25V, f = 1.0MHz 0.2 If = 5mA mV COUPLED SPECIFICATIONS Isolation Voltage Turn-On Time 5000 V T = 1 minute ms 1 Turn-Off Time ms 0.075 Isolation Resistance GΩ Coupled Capacitance pF Contact Transient Ratio © 2008 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 V/ 5 If = 5mA, Io = 500mA 2 If = 0mA, Io = 500mA 100 2 µs 2000 Page 2 of 5 7000 dV = 50V AD2C541 rev 1.42 (5/15/2008) AD2C541 1 Form A Solid State Relay AD2C541 AD2C541 Typical Turn-On Time Distribution N = 100, Ambient Temperature = 25°C Typical Turn-Off Time Distribution N = 100, Ambient Temperature = 25°C 60 50 40 30 20 10 0 Device Count 0.6 0.8 1 1.2 1.4 1.6 1.8 60 50 40 30 20 10 0 2 0 0.03 0.05 0.08 0.1 0.13 0.15 0.18 Turn-On Tim e (m s) Turn-Off Tim e (m s) AD2C541 AD2C541 Typical On-Resistance Distribution N = 100, Ambient Temperature = 25°C Typical Leakage Current Distribution N = 100, Ambient Temperature = 25°C 100 Device Count 30 20 10 0 80 60 40 20 0 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 On-Resistance (ohm s) Leakage Current (uA) AD2C541 Maximum Load Current vs. Temperature 64 66 68 70 72 74 76 78 Blocking Voltage (V) © 2008 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 80 0 60 10 40 20 -2 0 30 600 500 400 300 200 100 0 -4 0 Device Count 40 Load Current (mA) AD2C541 Typical Blocking Voltage Distribution N = 100, Ambient Temperature = 25°C 20 Device Count 40 0 Device Count PERFORMANCE DATA Tem perature (C) Page 3 of 5 AD2C541 rev 1.42 (5/15/2008) AD2C541 1 Form A Solid State Relay MECHANICAL DIMENSIONS 4 PIN DUAL IN-LINE PACKAGE 4 PIN SURFACE MOUNT DEVICE END VIEW END VIEW TOP VIEW TOP VIEW BOTTOM VIEW BOTTOM VIEW © 2008 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 Page 4 of 5 AD2C541 rev 1.42 (5/15/2008) AD2C541 1 Form A Solid State Relay DISCLAIMER Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO reserves the right to make changes to product description, specifications at any time without further notice. SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent licenses nor indemnity are expressed or implied. Except as specified in SSO's Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other warranty, expressed or implied, including merchantability and fitness for particular use. LIFE SUPPORT POLICY SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be reasonably expected to result in significant injury to the user, or (d) a critical component in any component of a life support device or system whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness. © 2008 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 Page 5 of 5 AD2C541 rev 1.42 (5/15/2008)