ExitPoint™ Directional Sounder with Voice Messaging Triggered by existing fire detection systems, directional sounders positioned at carefully chosen locations guide building occupants along escape routes and to perimeter building exits. Features • Listed to UL 464 (indoor applications only) • Five field-selectable power settings • Four field-selectable routing evacuation patterns • Constructed to be effective in unfamiliar surroundings or poor visibility • Designed to work in open areas, corridors or stairs • Fifteen different language selections available • Reduces evacuation times by as much as 75 percent • Optional disable feature for use in conjunction with a control module or heat sensor • Low profile, compact design The ExitPoint directional sounder model PF24V has an integral audio amplifier that produces a pulsating sound consisting of broadband low, mid and high range sounds. The broadband noise makes it possible to determine the location of the sound. There are four pulse patterns that can be used to create an egress pathway out of a building and to mark perimeter exits. In addition to the broadband noise, the sounder is capable of playing an alert message in the form of a recorded voice message or other audible signals. These messages will instruct the occupants of what action to take as they approach the directional sounder, and will allow them to react quickly and confidently when the sounder is activated. Fifteen different language combinations are available to instruct occupants that they are nearing an exit, a stairway up, a stairway down, or an area of refuge. The PF24V directional sounder also incorporates an optional disable feature for use in conjunction with a control module or heat sensor. The directional sounder features a number of field selectable power settings including high, medium-high, medium, medium-low, and low. Installation ease and pleasing aesthetics are achieved by a low profile compact design, and by the ability to flush mount in a 4˝ × 4˝ × 2¼˝ back-box. ExitPoint directional sounders, fitted in addition to normal building evacuation sounders, draw people to evacuation routes in both good and poor visibility. The PF24V directional sounder can be used in a wide range of building applications. Trials consistently have shown an improvement of up to 75 percent in evacuation times in smoke and up to 35 percent without smoke. The 2007 Edition of NFPA 72 now provides installation and maintenance guidelines on directional sounders. Agency Listings S0411 3027815 7135-1653:175 492-04-E Specifications Electrical Specifications Mechanical Specifications Voltage Input Operating Voltage Range Operating Temperature Power Setting Input Terminals Speaker Size Grille Size Regulated 24 Volts 16 to 33 Volts 32°F to 120°F (0°C to 49°C) High, medium-high, medium, medium-low, and low. Current Draw Measurements and Sound Output Guide Speed Selection Speed Fast (Exit) Fast (Exit) Fast (Exit) Fast (Exit) Fast (Exit) Med-Fast Med-Fast Med-Fast Med-Fast Med-Fast Med-Slow Med-Slow Med-Slow Med-Slow Med-Slow Slow Slow Slow Slow Slow DIP Switch Power Selection Setting 10 High 10 Med-High 10 Med 10 Med-Low 10 Low 9 High 9 Med-High 9 Med 9 Med-Low 9 Low 8 High 8 Med-High 8 Med 8 Med-Low 8 Low 7 High 7 Med-High 7 Med 7 Med-Low 7 Low Maximum DC Operating Current (mA RMS) (16 to 33V) 185 131 78 76 64 170 124 75 73 62 135 104 67 65 57 120 92 62 61 54 Audibility (dBA) (16 to 33V) Audibility (dBA) (16 to 33V) Note 1 Note 2 84 81 78 75 72 83 80 77 74 71 82 79 76 73 70 82 79 76 73 70 75 72 69 66 63 74 71 68 65 62 73 70 67 64 61 72 69 66 63 60 Note 1: Sound output measured in anechoic room at 10 feet. Note 2: Sound output measured in a reverberant room at 10 feet. Power Setting Guide DIP Switch Position 1 Setting Off On Off Off On DIP Switch Position 2 Setting Off Off On Off On DIP Switch Position 3 Setting Off Off Off On On Power Setting High Med-High Med Med-Low Low Ordering Information Part No. PF24V Accessories BBS-SP201W 12–24 AWG 4˝ (101 mm) 47/8˝ (127 mm) Additional Tone Selection Switch Position 5 Setting Switch Position 6 Setting Sound Output On On Area of Refuge On Off Up Stairs Off On Down Stairs Off Off Exit Here Enable/Disable Selection Switch Position 4 Setting Terminals 3 &4 Sound Output On Open Disabled On Closed Enabled Off Open Enabled Off Closed Disabled Language/audible tone selection guide Rotary Switch Selection 0 1 2 3 Tone/Language Audible tone/sweep English Spanish French 4 5 6 7 8 9 10 11 12 13 14 15 English/Spanish English/French Korean Cantonese Mandarin English/Cantonese English/Mandarin Cantonese/Mandarin English/Korean English/Portuguese English/Russian English/Polish Description ExitPoint™ Directional Sounder with Voice Messaging Surface mount back-box skirt for PF24V 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0377-002 • 1/07 • #1761