TENSILITY 10

part number: 10-00119
description: Cable, 2000 mm, 50-00011 locking dc plug
to stripped/tinned leads, 18 AWG, UL1185,
shielded
date:
unit:
page:
rev:
05/28/09
mm
1 of 3
A
Specifications:
plug description (1)
Ø2.50 x 5.50 x 30 ± 0.5, black insulator, P/N 50-00011
plug overmold (2)
30P, PVC, black
cable description (3)
UL1185, 0.16 x 41 strands, shield wire, 1F
cable outer diameter
Ø3.4 ± 0.1
cable color
black
cable gauge
AWG #18
cable length
2000 ± 50
twist tie (4)
black, 89 ± 3, non-toxic
rated load
12 Vdc @ 5 A
Notes:
Function test: no open, no reversed polarity, no short circuit, no INT
Hi-POT test: 600 Vac, 0.5 mA, 1 sec.
RoHS compliant
Mechanical drawing:
Initial
Date
29033 Avenue Sherman Ste 203 Valencia, CA 91355
tolerance
X: ±0.5 mm
.X: ±0.3 mm
ph 661.702.0035 fx 661.702.0038
.XX: ±0.05 mm
www.tensility.com
part number: 10-00119
description: Cable, 2000 mm, 50-00011 locking dc plug
to stripped/tinned leads, 18 AWG, UL1185,
shielded
date:
unit:
page:
rev:
05/28/09
mm
2 of 3
A
Cable specifications:
conductors
gauge
18 AWG
material
brass copper
cord size
41/0.16 TC
insulation
material
F0040C 50PB (4370) UL 80°C
color
white
diameter
Ø1.60 ± 0.05
jacket
material
F0208C 60P (4026) UL 80°C
color
black
diameter
Ø3.4 ± 0.10
electrical & physical properties
spiral shield
41/0.16 TC
rated voltage
300 V
rated temperature
80 °C
insulation resistance
0.76 (15.6 °C) mΩ / m min.
resistance @ 20 °C
21.8 mΩ/m max
material
insulation
jacket
tensile strength (kfg/mm2 min)
1.05
1.05
elongation (%min)
100
100
condition
113°C/168 h
113°C/168 h
elongation (% unaged min)
65
65
tensile strength (% unaged min)
75
75
deformation (121± 1 °C x 1 hour)
≤50%
≤50%
cold bend (-10 ± 1 °C x 1 hour)
OK
OK
heat shock (121 ± 1 °C x 1 hour)
OK
OK
flame test
VW-1
VW-1
unaged
aging test
Cable cross section:
conductor
insulation
shield
PVC jacket
29033 Avenue Sherman Ste 203 Valencia, CA 91355
ph 661.702.0035 fx 661.702.0038
www.tensility.com
part number: 10-00119
description: Cable, 2000 mm, 50-00011 locking dc plug
to stripped/tinned leads, 18 AWG, UL1185,
shielded
date:
unit:
page:
rev:
05/28/09
mm
3 of 3
A
Revision notes:
Rev
Date
Description
A
May 28, 2009
initial release
Specification Approval
Spec sign-off verifies that you have reviewed the entire specification, tested a sample of the product, and
confirm that it meets your requirements. This specification reflects the part as it will be ordered. Orders
will not be processed until the specification pages have been initialed and the approval page has been
signed. This specification is confidential and is not to be transmitted without prior approval from Tensility.
Signature
Title
Name
Date
29033 Avenue Sherman Ste 203 Valencia, CA 91355
ph 661.702.0035 fx 661.702.0038
www.tensility.com