VANLONG SF5009

915.75 MHz SAW Filter
•
•
•
•
Ideal Front-End Filter for 915.75 MHz Receivers
Low-Loss, Coupled-Resonator Quartz Design
Simple External Impedance Matching
Ultra Miniature Ceramic QCC8C Package
SF5009
Absolute Maximum Rating (Ta=25°C)
Rating
Unit
Input Power Level
Parameter
10
dBm
DC Voltage VDC
12
V
Operating Temperature Range
-10 ~ +60
°C
Storage Temperature Range
-40 ~ +85
°C
Electronic Characteristics
Parameter
Sym
Minimum
Typical
Maximum
Unit
fc
NS
915.75
NS
MHz
Insertion Loss
IL
-
15.0
16.5
dB
3dB Bandwidth
BW3
-
2.6
-
MHz
at fc - 5.0 MHz
-
35
46
-
dB
at fc + 5.0 MHz ~ +200.0 MHz
-
32
43
-
dB
Operating Temperature Range
Tc
-10
-
+60
°C
Turnover Temperature
To
25
40
55
°C
Turnover Frequency
fo
-
fc
-
KHz
Frequency Temperature Coefficient
FTC
-
-
-0.032
ppm/°C
Absolute Value during the First Year
|fA|
-
-
10
ppm/yr
-
1.0
-
-
MΩ
Frequency (25°C)
Rejection
Temperature Stability
Frequency Aging
Nominal Frequency
DC Insulation Resistance Between any Two Pins
NS = Not Specified
Notes:
1.
The frequency fC is defined as the midpoint between the 3dB
frequencies.
2.
Unless noted otherwise, all measurements are made with the filter
installed in the specified test fixture that is connected to a 50Ω test
system with VSWR ≤ 1.2:1. The test fixture L and C are adjusted
for minimum insertion loss at the filter center frequency, fC. Note
that insertion loss, bandwidth, and passband shape are dependent
on the impedance matching component values and quality.
5.
Turnover temperature, T0, is the temperature of maximum (or
turnover) frequency, f0. The nominal frequency at any case
temperature, TC, may be calculated from: f = f0 [1 - FTC (T0 - TC)2].
6.
The specifications of this device are based on the test circuit
shown above and subject to change or obsolescence without
notice.
7.
All equipment designs utilizing this product must be approved by
the appropriate government agency prior to manufacture or sale.
3.
Unless noted otherwise, specifications apply over the entire
specified operating temperature range.
8.
4.
Frequency aging is the change in fC with time and is specified at
+65°C or less. Aging may exceed the specification for prolonged
temperatures above +65°C. Typically, aging is greatest the first
year after manufacture, decreasing in subsequent years.
Our liability is only assumed for the Surface Acoustic Wave (SAW)
component(s) per se, not for applications, processes and circuits
implemented within components or assemblies.
9.
For questions on technology, prices and delivery please contact
our sales offices or e-mail [email protected].
Phone: +86 10 6301 4184
© 2004 by Vanlong Technology Co., Ltd.
Fax: +86 10 6301 9167
Email: [email protected]
Web: http://www.vanlong.com
SF5009
915.75 MHz SAW Filter
Package Dimensions (QCC8C)
Electrical Connections
Terminals
1
2
5
6
3,7
4,8
Connection
Input
Input Ground
Output
Output Ground
To be Grounded
Case Ground
Package Dimensions
Dimensions
A
B
C
D
Marking
Nom (mm)
2.08
0.60
1.27
2.54
Dimensions
E
F
G
H
Nom (mm)
1.20
1.35
5.00
5.00
Test Circuit
1.
F5009 - Part Code
F5009
2.
Frequency (MHz) in 5 digits
915.75
3.
Date Code:
YWW
Y : Last digit of year
WW : Week No.
C = 4.0pF
Ls1 = 1.5 tunes of 0.5mm insulated copper, 3.0mm ID.
Ls2 = 2.0 tunes of 0.5mm insulated copper, 3.0mm ID
Typical Frequency Response
Phone: +86 10 6301 4184
© 2004 by Vanlong Technology Co., Ltd.
Fax: +86 10 6301 9167
Email: [email protected]
Web: http://www.vanlong.com
SF5009