XPPOWER AMM120PS48

AC-DC
120 Watts
xppower.com
AMM120 Series
•
Energy Star Level V ≥ 24 V
•
CEC 2008 & EISA 2007 Compliant
•
Worldwide Medical Approvals
•
Small Size/High Power Density
•
Class I and Class II Versions
•
Operating Temperature up to +60 °C
•
Locking Output Connector
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
Inrush Current
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
• 0.98 typical
Earth Leakage Current • 90 µA max at 115 VAC/60 Hz,
(Class I Versions)
150 µA max at 230 VAC/50 Hz
Input Protection
• Internal 3 A fuse in live and neutral lines
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
12 to 48 VDC
Not user-adjustable
±2 %
No minimum load required
2 s max at 115 VAC
<80 ms at 115 VAC
15 ms minimum at full load & 115 VAC
0.5% maximum
Total regulation <±5%
4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
• Unit shuts down, recycle input to reset
Protection
Overload Protection
• 110-150%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
• 0.04%/°C
Coefficient
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 85% typical
• 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
• 40-120 kHz variable
• 3.7 W/In3
• >175 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Cooling
• Convection-cooled
Operating Humidity
• 10-95% RH, non-condensing
Storage Temperature
• -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55011/FCC/VCCI, Class B conducted
EN55011/FCC/VCCI, Class B radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
• EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B (Perf Criteria A, A, B
with 70% load)
• EN60601-1, UL60601-1, CSA22.2 No.
601-1 per cUL, CE Mark
Output
Power
96 W
105 W
120 W
120 W
120 W
120 W
120 W
120 W
120 W
Output
Voltage
12 V
15 V
18 V
19 V
20 V
24 V
30 V
36 V
48 V
Total
Regulation(2)
5%
5%
5%
5%
5%
5%
5%
5%
5%
Output
Current
8.00 A
7.00 A
6.67 A
6.32 A
6.00 A
5.00 A
4.00 A
3.34 A
2.50 A
Model
Number(3, 4)
AMM120PS12
AMM120PS15
AMM120PS18
AMM120PS19
AMM120PS20
AMM120PS24
AMM120PS30
AMM120PS36
AMM120PS48
Notes
1.
2.
3.
4.
Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point.
Total regulation includes initial set accuracy, line and load regulation.
For class II versions, add ‘-C2’ to model number e.g. AMM120PS24-C2.
For optional barrel jack connector add suffix ‘B1’ to model number e.g. AMM120PS24C2B1.
Mechanical Details
Cable length approx 48” (1220mm)
1 3
2
4
1.72
Power On Indicator
(43.7)
Pin
1
2
3
4
Rubber foot
(4 places.)
Function
Return
Output+
Return
Output+
6.30
(160.0)
3.00 (76.2)
Optional Barrel Jack Connector
0.433 (11.0)
0.02
(0.5)
0.083 (2.1)
0.217
(5.5)
0.413
(10.5)
AC Input
IEC 320-C14 Inlet - For Class I version
IEC 320-C18 Inlet - For Class II version
Notes
1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length.
2. Maximum load per pin on output connector is 5 A.
3. Output connector is KYCON KPP-4P locking type. For mating half, use KYCON KPJ-4S-S or equivalent.
4. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input.
5. Weight 1.72 lbs (780 g).
01-Dec-08
AC-DC
AMM120
Models and Ratings