XPPOWER AML120PS19

AC-DC
120 Watts
xppower.com
AML120 Series
•
Energy Star Level V ≥ 18 V
•
CEC 2008 & EISA 2007 Compliant ≥15V
•
High Power Density
•
Single Outputs from 12 V to 48 V
•
High Efficiency
•
0 °C to +70 °C Operating Temperature
•
Non-standard Connectors Available
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
Inrush Current
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
• 0.98 typical at 115 VAC
Earth Leakage Current • 150 µA max at 115 VAC, 60 Hz
250 µA max at 230 VAC, 50 Hz
Input Protection
• Internal 3 A fuse
Standby Power
• <0.75 W
Consumption
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
12 to 48 VDC
Not user-adjustable
±2%
No minimum load required
2 s max at 115 VAC
<80 ms at 115 VAC
15 ms minimum at full load and 115 VAC
±0.5% maximum
See table
4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
• Unit shuts down, recycle input to reset
Protection
Overload Protection
• 110-150%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
• 0.04%/°C
Coefficient
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 86% typical,
80% min for 12 V & 15 V models
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 20-110 kHz variable
• 4.9 W/In3
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +50 °C to 60% power at +70 °C
Cooling
• Convection-cooled
Operating Humidity
• 10-95% RH, non-condensing
Storage Temperature
• -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
• EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark
Output
Power
96 W
105 W
120 W
120 W
120 W
120 W
120 W
120 W
120 W
Output
Voltage
12 V
15 V
18 V
19 V
20 V
24 V
30 V
36 V
48 V
Total
Regulation(2)
5%
5%
5%
5%
5%
5%
5%
5%
5%
Output
Current
8.00 A
7.00 A
6.67 A
6.32 A
6.00 A
5.00 A
4.00 A
3.34 A
2.50 A
Model
Number
AML120PS12†
AML120PS15†
AML120PS18
AML120PS19†
AML120PS20
AML120PS24†
AML120PS30
AML120PS36†
AML120PS48†
Notes
1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point.
2. Total regulation includes initial set accuracy, line and load regulation.
† Available from Farnell. See pages 204-206.
Mechanical Details
Cable length approx 71” (1800mm)
1 3
2
4
1.46
Power On Indicator
(37.0)
Pin
1
2
3
4
Shell
6.58 (167.0)
Rubber foot
(4 places.)
Function
Return/Input Earth
Output +
Return/Input Earth
Output +
Return/Input Earth
0.02
(0.5)
2.56 (65.0)
AC Input
IEC 320-C6 Inlet
(Mates with a C5 plug)
Notes
1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length.
2. Maximum load per pin on output connector is 5 A.
3. Optional output connectors available. Consult sales.
4. Output connector is Kycon part KPP-4P or equivalent. Mating connector Kycon part KPJ-4S.
01-Dec-08
AC-DC
AML120
Models and Ratings