XPPOWER VEH90PS12

ACDC
90 Watts
VEH Series
xppower.com
•
Energy Efficiency Level V
•
CEC 2008 & EISA 2007 Compliant
•
High Power Density
•
Single Outputs from 12 V to 24 V
•
No Load Input Power <0.5 W
•
Optional Output Connector
•
Low Cost
B R A N D
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
General
•
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
1.5 A max at 90 VAC
110 A max at 230 VAC, cold start at 25 °C
<1 mA at 230 VAC/50 Hz
>0.95 at 230 VAC and full load
<0.5 W
Internal T2.0A/250 V fuse in line
Switching Frequency
MTBF
• See table
• Level V
• 3000 VAC Input to Output,
1500 VAC Input to Ground
PS12: 500 VDC Output to Ground,
PS19/24: Negative output is connected to
Ground
• PFC: 25-125 kHz, PWM: 60 kHz typical
• >160 kHrs to Bell Core iss. 6
Environmental
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Hold Up Time
Start Up Delay
Start Up Rise Time
Transient Response
•
•
•
•
•
•
•
Line Regulation
Load Regulation
Ripple & Noise
•
•
•
Overvoltage Protection •
Overload Protection
•
Short Circuit Protection •
Temperature
Coefficient
Efficiency
Energy Efficiency
Isolation
•
See table
±5% at 50% load
No minimum load requirement
10 ms min at 115 VAC, full load
3 s max
8 ms typical
4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
±0.5% max
±5% max
1% pk-pk max, 20 MHz bandwidth
(see note 1)
See table
120 -180%
Continuous (hiccup/trip & restart mode
with auto recovery)
±0.04%/°C
Operating Temperature • 0 °C to +60 °C derate linearly from 100%
load at +40 °C to 50% load at +60 °C,
Storage Temperature • -10 ˚C to +85 °C
Operating Humidity
• 5% to 90% RH non-condensing
Storage Humidity
• 5% to 95% RH non-condensing
Shock
• 6 Random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Vibration
• 2 g variable frequency from 20 Hz to 30 Hz
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted & radiated
• EN61000-3-2 class A,
EN61000-3-2 class C >60% load
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• EN60950-1:2001, UL/cUL60950-1
Output Power
Output Voltage
Output Current
OVP Setting(2)
Effeciency(3)
Model Number(4)
90 W
90 W
90 W
12.0 V
19.0 V
24.0 V
7.50 A
4.74 A
3.75 A
16.0 V
25.0 V
32.0 V
88%
88%
89%
VEH90PS12†^
VEH90PS19†^
VEH90PS24†^
Notes
1. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF
electrolytic capacitor.
2. Typical values.
3. Average of efficiencies measured at 25%, 50%, 75% and 100% load and
230 VAC input.
4. For optional barrel jack connector, 2.5 mm inner positive, 5.5 mm outer
negative, 11 mm length add suffix ‘-B’ e.g. VEH90PS24-B
† Available from Farnell & element14. See page 28.
^ Available from Newark. See page 28.
Mechanical Details
1 3
2
Pin
1
2
3
4
Shell
5.24
(133.0)
4
Function
Output +
Output +
Return*
Return*
Floating
*Return is internally connected
to input earth on 19 V & 24 V
models
Power Cord, Order Part:
UK - UK-MAINS-5
European - EU-MAINS-5
US - US-MAINS-5
1.19
(30.3)
2.28
(58.0)
IEC320-C6
0.67
(17.0)
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length.
2. Weight 0.82 lbs (370 g) approx.
3. Cable length is 48”±2”(1220 ±50 mm) approx.
4. Output connector (Power Mini Din) mates with Kycon KPJ-4S or equivalent.
18-May-11
ACDC
VEH90
Models and Ratings