ACDC 90 Watts VEH Series xppower.com • Energy Efficiency Level V • CEC 2008 & EISA 2007 Compliant • High Power Density • Single Outputs from 12 V to 24 V • No Load Input Power <0.5 W • Optional Output Connector • Low Cost B R A N D Specification Input Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current Power Factor No Load Input Power Input Protection General • • • • • • • • 90-264 VAC 47-63 Hz 1.5 A max at 90 VAC 110 A max at 230 VAC, cold start at 25 °C <1 mA at 230 VAC/50 Hz >0.95 at 230 VAC and full load <0.5 W Internal T2.0A/250 V fuse in line Switching Frequency MTBF • See table • Level V • 3000 VAC Input to Output, 1500 VAC Input to Ground PS12: 500 VDC Output to Ground, PS19/24: Negative output is connected to Ground • PFC: 25-125 kHz, PWM: 60 kHz typical • >160 kHrs to Bell Core iss. 6 Environmental Output Output Voltage Initial Set Accuracy Minimum Load Hold Up Time Start Up Delay Start Up Rise Time Transient Response • • • • • • • Line Regulation Load Regulation Ripple & Noise • • • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature Coefficient Efficiency Energy Efficiency Isolation • See table ±5% at 50% load No minimum load requirement 10 ms min at 115 VAC, full load 3 s max 8 ms typical 4% maxiumum deviation, recovering to less than 1% within 500 µs for a 50% step load change ±0.5% max ±5% max 1% pk-pk max, 20 MHz bandwidth (see note 1) See table 120 -180% Continuous (hiccup/trip & restart mode with auto recovery) ±0.04%/°C Operating Temperature • 0 °C to +60 °C derate linearly from 100% load at +40 °C to 50% load at +60 °C, Storage Temperature • -10 ˚C to +85 °C Operating Humidity • 5% to 90% RH non-condensing Storage Humidity • 5% to 95% RH non-condensing Shock • 6 Random drops from 0.7 m with no damage, 50 g for 20 ms in each of 3 axes Vibration • 2 g variable frequency from 20 Hz to 30 Hz EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55022, level B conducted & radiated • EN61000-3-2 class A, EN61000-3-2 class C >60% load • EN61000-3-3 • EN61000-4-2, level 3 Perf Criteria A • EN61000-4-3, 3 V/m Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A • EN61000-4-5, installation class 3, Perf Criteria A • EN61000-4-6, level 2 Perf Criteria A • EN61000-4-8, 3 A/m Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B • EN60950-1:2001, UL/cUL60950-1 Output Power Output Voltage Output Current OVP Setting(2) Effeciency(3) Model Number(4) 90 W 90 W 90 W 12.0 V 19.0 V 24.0 V 7.50 A 4.74 A 3.75 A 16.0 V 25.0 V 32.0 V 88% 88% 89% VEH90PS12†^ VEH90PS19†^ VEH90PS24†^ Notes 1. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. 2. Typical values. 3. Average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 4. For optional barrel jack connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix ‘-B’ e.g. VEH90PS24-B † Available from Farnell & element14. See page 28. ^ Available from Newark. See page 28. Mechanical Details 1 3 2 Pin 1 2 3 4 Shell 5.24 (133.0) 4 Function Output + Output + Return* Return* Floating *Return is internally connected to input earth on 19 V & 24 V models Power Cord, Order Part: UK - UK-MAINS-5 European - EU-MAINS-5 US - US-MAINS-5 1.19 (30.3) 2.28 (58.0) IEC320-C6 0.67 (17.0) Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight 0.82 lbs (370 g) approx. 3. Cable length is 48”±2”(1220 ±50 mm) approx. 4. Output connector (Power Mini Din) mates with Kycon KPJ-4S or equivalent. 18-May-11 ACDC VEH90 Models and Ratings