XPPOWER SDS120PS12B

AC-DC
120 Watts
xppower.com
SDS120 Series
•
Single, Dual & Triple Outputs
•
Convection-cooled
•
3” x 5” Footprint
•
High Efficiency to 85%
•
Open Frame, U-Channel & Covered Versions
•
Low Temperature Option
•
Optional Power Fail Detect Signal
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 1.7 A at 115 VAC
1.0 A at 230 VAC
Inrush Current
• <30 A at 115 VAC
<55 A at 230 VAC
Power Factor
• 0.97 typical
Earth Leakage Current • <0.30 mA at 115 VAC
<0.75 mA at 230 VAC
Input Protection
• 3.15 A on board fuse
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
• See table
• ±5% output 1 only (3.3 V variant ±10%)
• Single output models: ±1%
Multi-output models: ±5%
Minimum Load
• No minimum load required for single
output models. For multi-output models
see table.
Start Up Delay
• 2 s max
Start Up Rise Time
• 2 ms
Hold Up Time
• >16 ms
Line Regulation
• 1% maximum, ±0.5% typical
Load Regulation
• 5% maximum, ±3.0% typical
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 1% pk-pk typical, 20 MHz BW
Overvoltage Protection • 112-132% V1 only, recycle input to reset
Overload Protection
• All outputs: 110-150% with auto recovery
(primary power limit)
Short Circuit Protection • Trip & restart (Hiccup mode),
auto recovery
Temperature
• 0.04%/°C
Coefficient
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 80% typical, 85% max,
230 VAC 100% load
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• PFC 100 kHz, PWM 67 kHz
• 4.87 W/In3
• Power Fail Detect = TTL active low,
combined AC and DC OK signal (option)
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +50 °C to 50% load at +70 °C,
low temperature option ‘-L’ -40 °C
Cooling
• Convection-cooled
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, CISPR22 and FCC, part 15
level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, >95% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA60950-1 per cUL, CE Mark LVD
Max.
Power
72.0
110.0
115.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
79.5
120.0
120.0
91.5
91.5
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
120.0
Vnom
3.3 V
5.0 V
7.0 V
9.0 V
12.0 V
15.0 V
18.0 V
24.0 V
28.0 V
36.0 V
48.0 V
3.3 V
5.0 V
5.0 V
5.0 V
3.3 V
5.0 V
28.0 V
3.3 V
3.3 V
3.3 V
3.3 V
3.3 V
3.3 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Output 1
Imin
Imax
0.00 A
22.00 A
0.00 A
22.00 A
0.00 A
16.42 A
0.00 A
13.33 A
0.00 A
10.00 A
0.00 A
8.00 A
0.00 A
6.66 A
0.00 A
5.00 A
0.00 A
4.28 A
0.00 A
3.33 A
0.00 A
2.50 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
0.39 A
3.92 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
1.50 A
15.00 A
Tol.(1)
5%
5%
5%
4%
3%
3%
3%
2%
2%
2%
2%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
Vnom
12.0
12.0
15.0
24.0
5.0
-24.0
5.0
5.0
5.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
15.0
15.0
24.0
24.0
24.0
24.0
10.0
10.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Output 2
Imin
Imax
0.20
0.20
0.20
0.10
0.40
0.20
0.20
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.35
0.35
0.35
0.35
0.60
0.60
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
6.0
6.0
6.0
3.5
6.0
2.0
2.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
3.5
3.5
3.5
3.5
6.0
6.0
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Tol.(1)
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
Vnom
12.0
-12.0
5.0
-5.0
-12.0
12.0
5.0
-5.0
-12.0
12.0
-15.0
15.0
-24.0
24.0
-12.0
12.0
-10.0
10.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Output 3
Imin
Imax
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
1.0
1.0
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Tol.(1)
Model
Number(2, 4, 5)
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
SDS120PS03B†
SDS120PS05B†
SDS120PS07B
SDS120PS09B
SDS120PS12B†
SDS120PS15B†
SDS120PS18B
SDS120PS24B†
SDS120PS28B
SDS120PS36B
SDS120PS48B†
SDS120PD01B
SDS120PD02B
SDS120PD03B
SDS120PD04B
SDS120PD00B
SDS120PD05B
SDS120PD06B
SDS120PT00B†
SDS120PT01B
SDS120PT02B
SDS120PT03B
SDS120PT04B
SDS120PT05B
SDS120PT06B
SDS120PT07B†
SDS120PT08B†
SDS120PT09B
SDS120PT10B†
SDS120PT11B
SDS120PT12B
SDS120PT13B
SDS120PT14B
SDS120PT15B†
SDS120PT16B
SDS120PT17B
Notes
1. Total regulation includes initial set accuracy, line regulation and load regulation.
2. For optional PCB only version, delete suffix ‘B’ from model number. Example
SDS120PS03.
3. For non-standard voltages contact sales office.
4. For optional Power Fail Detect circuit, add suffix ‘P’ to model number
5. For optional -40 ˚C operation, add suffix ‘-L’ to model number.
† Available from Farnell. See pages 204-206.
Mechanical Details
1.18 (30.0)
All dimensions are in inches (mm).
Weight: 0.77-0.99 lbs (350-450 g) approx.
For PCB-only version, overall dimensions are max 5.00 x 3.00 x 1.44 (127.0 x 76.2 x 36.6).
0.25 (6.4)
4.49 (114.3)
0.10 (2.5)
1.54 (39.2)
N
13
PFD
G
2.70 (68.6)
0.55 (14.0)
3.90 (99.06)
PIN CONNECTIONS
Single
Dual
Triple
V1
V2
V2
V1
V2
V2
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
Return Common Common
Return Common Common
Return Common Common
Return
N/C
V3
Return Common Common
Return Common Common
PFD(1)
PFD(1)
PFD(1)
Power Fail Detect (PFD)
is +5 V for normal operation.
+5 V
Source current is 5 mA max.
Pin 13
PFD is <0.4 V for either
AC Fail (<90 VAC) or
DC Fail (<95% Vnom).
Sink current is 10 mA max.
Internal
Notes:
5.00 (127.0)
4.49 (114.3)
3.20 (81.4)
DC
OUTPUT
AC
P1
INPUT
L
2.57 (65.3)
P2
1
M3xP0.5 (Mounting Holes) X 3
4.00 (101.6)
0.25 (6.4)
1.18 (30.0)
3.01+0.20 0.00 (76.4 +0.5 0.0)
3.20+0.20 0.01 (81.4 +0.5 -0.2)
M3XP0.5 (Mounting Holes) X 4
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
1.
2.
3.
4.
Optional Power Fail Detect signal on ‘P’ versions only. Standard models pin 13 is N/C.
I/P connector P1 mates with Molex housing 09-50-3051 & Molex 2878 series crimp terminal.
O/P P2 mates with Molex housing 09-50-3131 & Molex 2878 series crimp terminal.
For optional cover kit order part number SDS120 COVER†, to receive unit with cover fitted
add suffix ‘C’ to model number (overall height is 1.73 (44.0)).
5. For mating connector kit order part number SDS120 CON KIT†.
6. For cable harness order part number SDS120S LOOM† for single output models &
SDS120M LOOM† for multi-output models.
7. DIN clips are available for alternate mounting order 2 x ‘DIN CLIP’.
17-Apr-07
AC-DC
SDS120
Models and Ratings