XPPOWER CLC175US24

AC-DC
175 Watts
xppower.com
CLC175 Series
•
High Efficiency Resonant Topology
•
High Power Density 9.3 W/in3
•
12 V Fan Output as Standard
•
Remote Sense as Standard
•
5V Standby Option
•
Remote On/Off Option
•
Power Good Signal Option
Specification
Input
General
Input Voltage
• 85-264 VAC (120-370 VDC), derate output
power <90 VAC (See derating curve)
Input Frequency
• 47-63 Hz
Input Current
• 3.0 A typical at 115 VAC, full load
1.5 A typical at 230 VAC, full load
Inrush Current
• 40 A max at 230 VAC, cold start 25 ºC
Power Factor
• EN61000-3-2, class A
Earth Leakage Current • 200/400 µA 115/230 VAC at 50 Hz
475 µA 264 VAC at 60 Hz
Input Protection
• Internal 5 A fuse
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
•
•
•
•
•
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
Remote Sense
Remote On/Off
(Inhibit/Enable)
(Option -A)
•
•
•
•
12-48 V (see tables)
±5%
±1% V1, ±5% V2, ±3% V3
0.1A required for V2 regulation when used
1 s typical, see longform datasheet for
more details
50 ms
16 ms min at 115 VAC
±0.2% after 20 min warm up
±0.5% max
±1% V1, ±5% V2 & V3 max
5% typical
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
1% pk-pk V1, others 2%,
20 MHz bandwidth
115-140% Vnom, recycle input to reset
110-150% V1 only
Continuous trip and restart (Hiccup mode)
0.05%/˚C
• Compensates for 0.5 V total voltage drop
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1 & V2
Efficiency
Isolation
Switching Frequency
Signals (Option -A)
MTBF
• 87% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 70 kHz typical
• Power OK - open collector,
Remote On/Off, 5 V Standby
• 390 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C
at 2.5%/˚C to 50% load at +70 ˚C. See
derating curve and longform datasheet for
thermal information.
Cooling
• Forced-cooled >10 CFM
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axis
Vibration
• 2 g rms, 5 Hz to 500 kHz, 3 axis
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level as below
Emissions
• EN55022 level B conducted
EN55022 level A radiated
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
Safety Approvals
• IEC60950-1 CB report, CSA 22.2 No.
60950-1, UL60950-1, TUV EN60950-1
Max Output Power(1)
Output Voltage V1
Max
Output Current V1
Fan Output
V2
Standby Supply
V3 (optional)
175 W
12.0 VDC
13.9 A
12.0 V/0.5 A
5.0 V/0.5 A
CLC175US12
175 W
24.0 VDC
6.9 A
12.0 V/0.5 A
5.0 V/0.5 A
CLC175US24
175 W
48.0 VDC
3.5 A
12.0 V/0.5 A
5.0 V/0.5 A
CLC175US48
Model Number(2)
Notes
1. 10 CFM airflow.
2. For V3 5 V standby, Power OK & Inhibit, add suffix ‘-A’ to model number.
Mechanical Details
5.00 (127.0)
4.55 (115.6)
0.22 (5.7)
1.30
(33.0)
0.20 (5.1)
3.00
(76.2)
1.90
(48.3)
2.50
(63.6)
2.55
(64.8)
0.61
(15.6)
1.11
(28.3)
0.23 (5.7)
0.20 (5.1)
0.25 Faston
Ground Tab
V Adj.
0.18
(4.6)
4 x ø0.156 (3.96) Mounting Holes
ø0.312 (7.92) Clearance Top & Bottom
Input Connector J1
Pin 1
Line
Pin 2
Neutral
0.25”Faston
Earth
J1 mates with Molex housing
09-50-1031 and Molex series
5194 crimp terminals.
0.19 (4.8)
SMD component height
0.14
(3.5)
Output Connector J2
Pin
Single
1
+V1
2
+V1
3
+V1
4
+V1
5
RTN
6
RTN
7
RTN
8
RTN
J2 mates with Molex
housing 09-50-1081 and
Molex series 5194 crimp
terminals.
Signal Connector J3
Pin
Single
1
+5V Standby
2
Logic GND
3
Logic GND
4
Power OK
5
Inhibit HI
6
Inhibit LO
7
+Sense
8
-Sense
9
+Vout
10
-Vout
Fan Connector J4
Pin 1
Fan +(12V)
Pin 2
Fan J4 mates with Molex housing
22-01-1024 and Molex series
5103 crimp terminals.
J3 mates with JST housing
PHDR-10VS and JST series
SPHD-001T-P0.5 crimp
terminals.
Notes
1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
Derating Curves
Output Power (W)
Output Power (W)
175
175
158
85
90
264
Input Voltage (VAC)
88
0
+40
+50
+60
+70
Ambient Temperature (ºC)
30-Jul-08
AC-DC
CLC175
Models and Ratings