ZETTLER ACM1602Z-RN-GBW-C

DISPLAYTRONIC
XIAMEN ZETTLER ELECTRONICS CO., LTD.
SPECIFICATIONS FOR
LIQUID CRYSTAL DISPLAY
ACM1602Z CHARACTER MODULE VER1.0
CUSTOMER APPROVAL
※
PART
APPROVAL
NO.
ACM1602Z-RN-GBW-C
:
COMPANY
CHOP
CUSTOMER
COMMENTS
DISPLAYTRONIC ENGINEERING APPROVAL
DESIGN BY
CHECKED BY
APPROVED BY
ACM1602Z-RN-GBW-C
VER1.0
REVISION RECORD
REVISION
VER1.0
REVISION DATE
12/10-2006
PAGE
CONTENTS
FIRST ISSUE
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
1
ACM1602Z-RN-GBW-C
VER1.0
※ CONTENTS
1.0
MECHANICAL SPECS
2.0
ABSOLUTE MAXIMUM RATINGS
3.0
ELECTRICAL CHARACTERISTICS
4.0
OPTICAL CHARACTERISTICS (TA=25ºC, VDD= 3.0V)
5.0
BLOCK DIAGRAM
6.0
PIN ASSIGNMENT
7.0
POWER SUPPLY
8.0
TIMING CHARACTERISTICS
9.0
MECHANICAL DIAGRAM
10.0 RELIABILITY TEST
11.0 DISPLAY INSTRUCTION TABLE
12.0
CHARACTER PATTERNS
13.0 PRECAUTION FOR USING LCM
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
2
ACM1602Z-RN-GBW-C
VER1.0
1.0 MECHANICAL SPECS
1. Overall Module Size
(W*H*T)
41.2*47.5 *2.1(MAX)mm
2. Viewing Area
(W*H)
38.2X17.0mm
3. Dot Size
0.34*0.50
4. Dot Pitch
0.38*0.58
5. Driving Method
1/17D, 1/5B,4.8V
6. Controller IC
ST7032I
7. LCD Type
STN(GRAY) ,Positive ,Reflective
8. Viewing Direction
6 O’Clock
9.
Interface
I2C
10. Backlight
NO
11. Operating Temperature
Wide (-20ºC ~ 70ºC)
12. Rohs
Conforms
2.0 ABSOLUTE MAXIMUM RATINGS
Item
Symbol
Min
Typ
Max
Unit
Operating temperature
Top
-20
-
70
ºC
Storage temperature
Tst
-30
-
80
ºC
Input voltage
Vin
Vss
Vdd
V
Supply voltage for logic
Vdd- Vss
2.7
3.6
V
Supply voltage for LCD drive
Vdd- Vo
3.0
6.5
V
Typ
Max
Unit
3.0
3.2
V
1.0
mA
-
3.0 ELECTRICAL CHARACTERISTICS
3.1 Electrical Characteristics Of LCM
Item
Symbol
Condition
Min
Ta=25ºC
2.8
Vdd=3.0V
-
Power Supply Voltage
VDD
Power Supply Current
Idd
Input voltage (high)
Vih
H level
2.2
-
Vdd
V
Input voltage (low)
Vil
L level
0
-
0.6
V
-20ºC
-
25ºC
4.5
70ºC
4.0
Recommended LC Driving
Voltage
Vdd -Vo
3.2 The Characteristics Of
Item
Operate Current
5.5
4.8
5.0
V
-
Backlight
Symbol
Condition
Min
-
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
Typ
NO
Max
Unit
mA
3
ACM1602Z-RN-GBW-C
VER1.0
4.0 OPTICAL CHARACTERISTICS (Ta=25ºC, Vdd= 5.0V±0.25V, STN LC fluid)
Item
Symbol
Condition
Min
Typ
Max
Unit
Viewing angle (horizontal)
θ
Cr ≥ 2.0
-35
-
35
deg
Viewing angle (vertical)
φ
Cr ≥ 2.0
-25
-
45
deg
Contrast Ratio
Cr
φ=0°, θ=0°
3.0
Response time (rise)
Tr
φ=0°, θ=0°
-
150
250
ms
Response time (fall)
Tf
φ=0°, θ=0°
-
160
280
ms
-
(1). Definition of Optical Response Time
(2). Definition of Driving Voltage (Vlcd)
Vlcd=(V10,ON +V90,OFF)/2
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
4
ACM1602Z-RN-GBW-C
VER1.0
(3). Definition of Viewing Angle θ and Ф
NORMAL θ=0°
φ=180°
12:00
Y
VIEW
POSITION
θ
φ=270°
9:00
φ=90°
3:00
X
φ=0°
6:00
φ
5.0 BLOCK DIAGRAM
COM1
ICONS
16*2 CHAR.+ICONS
COM8
COM9
COM9
SEG1
SEG80
SEG80
SEG1
IC:ST7032I
COM16
COM1
COM8
COM16
COMI2
6 PINS
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
5
ACM1602Z-RN-GBW-C
6.0 PIN ASSIGNMENT
Pin No.
Symbol
1
VLCD
2
3
4
VER1.0
Function
Power supply for LCD drive
VSS
Ground
VDD
Power supply
SDA
DATA INPUT
RST
EXTERNAL RESET PIN
SCL
CLOCK INPUT
5
6
7.0 POWER SUPPLY
LCM
VDD
3.0V
3.3V
VSS
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
6
ACM1602Z-RN-GBW-C
VER1.0
8.0 TIMING CHARACTERISTICS
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
7
3.25
1.75 MIN
1
5.0 MAX
27.50
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
7.00±0.15
W=0.50±0.05
P1.0*(6-1)=5.00±0.10
01H
41H
00H
40H
42H
02H
43H
03H
真值表:
0.80 MAX
6.25 MIN
6
41.20
38.20 MIN V.A.
36.15 A.A.
46H
06H
47H
07H
48H
08H
49H
09H
4AH
0AH
4BH
0BH
4CH
0CH
4DH
0FH
4EH 4FH
0DH 0EH
5.26
2:1
LCM-1602Z-01
XIAMEN ZETTLER ELECTRONICS Co.,LTD
45H
05H
0.30±0.05
0.7
2.26
1.86
0.38
0.34
mm
2006-09-10
1/1
0.50
外形图
David
44H
04H
0.7
2.10 MAX
ACM1602Z-RN-GBW-C
VER1.0
9.0 MECHANICAL DIAGRAM
0.58
4.56
8.00 MAX
3.00±0.30
6.00±0.50
14.00 A.A.
17.00 MIN V.A.
20.25
20.00±0.50
8
ACM1602Z-RN-GBW-C
VER1.0
10.0 RELIABILITY TEST
Evaluations and Assessment*
Storage Condition
Content
Operation at high
temperature and
humidity
High temperature
storage
Low temperature
storage
Oozing
Contrast
Other Appearances
40ºC,90%
RH,120hrs
Current
Consumption
Twice initial
value or less
none
More than 80% of
initial value
No abnormality
60ºC,
1200hrs
-20ºC,
120hrs
Twice initial
value or less
Twice initial
value or less
none
More than 80% of
initial value
More than 80% of
initial value
No abnormality
No abnormality
*Evaluations and assessment to be made two hours after returning to room temperature (25ºC±5ºC).
*The LCDs subjected to the test must not have dew condensation.
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
9
ACM1602Z-RN-GBW-C
VER1.0
11.0 DISPLAY INSTRUCTION TABLE
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
10
ACM1602Z-RN-GBW-C
VER1.0
12.0 CHARACTER PATTERNS(ST7032I-OD)
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
11
ACM1602Z-RN-GBW-C
VER1.0
13.0 PRECAUTION FOR USING LCM
1. When design the product with this LCD Module, make sure the viewing angle matches to its purpose of usage.
2. As LCD panel is made of glass substrate, Dropping the LCD module or banging it against hard objects may
cause cracking or fragmentation. Especially at corners and edges.
3. Although the polarizer of this LCD Module has the anti-glare coating, always be careful not to scratch its
surface. Use of a plastic cover is recommended to protect the surface of polarizer.
4. If the LCD module is stored at below specified temperature, the LC material may freeze and be deteriorated. If
it is stored at above specified temperature, the molecular orientation of the LC material may change to Liquid
state and it may not revert to its original state. Excessive temperature and humidity could cause polarizer peel
off or bubble. Therefore, the LCD module should always be stored within specified temperature range.
5. Saliva or water droplets must be wiped off immediately as those may leave stains or cause color changes if
remained for a long time. Water vapor will cause corrosion of ITO electrodes.
6. If the surface of LCD panel needs to be cleaned, wipe it swiftly with cotton or other soft cloth. If it is not still
clean enough, blow a breath on the surface and wipe again.
7. The module should be driven according to the specified ratings to avoid malfunction and permanent damage.
Applying DC voltage cause a rapid deterioration of LC material. Make sure to apply alternating waveform by
continuous application of the M signal. Especially the power ON/OFF sequence should be kept to avoid latchup
of driver LSIs and DC charge up to LCD panel.
8. Mechanical Considerations
a) LCM are assembled and adjusted with a high degree of precision. Avoid excessive shocks and do not
make any alterations or modifications. The following should be noted.
b) Do not tamper in any way with the tabs on the metal frame.
c) Do not modify the PCB by drilling extra holes, changing its outline, moving its components or modifying its
pattern.
d) Do not touch the elastomer connector; especially insert a backlight panel (for example, EL).
e) When mounting a LCM makes sure that the PCB is not under any stress such as bending or twisting.
Elastomer contacts are very delicate and missing pixels could result from slight dislocation of any of the
elements.
f) Avoid pressing on the metal bezel, otherwise the elastomer connector could be deformed and lose
contact, resulting in missing pixels.
9. Static Electricity
a) Operator
Ware the electrostatics shielded clothes because human body may be statically charged if not ware shielded
clothes.
Never touch any of the conductive parts such as the LSI pads; the copper leads on the PCB and the interface
terminals
with any parts of the human body.
b) Equipment
There is a possibility that the static electricity is charged to the equipment, which has a function of peeling or
friction
action (ex: conveyer, soldering iron, working table). Earth the equipment through proper resistance
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
12
ACM1602Z-RN-GBW-C
VER1.0
(electrostatic
earth: 1x108 ohm).
Only properly grounded soldering irons should be used.
If an electric screwdriver is used, it should be well grounded and shielded from commutator sparks.
The normal static prevention measures should be observed for work clothes and working benches; for the
latter
conductive (rubber) mat is recommended.
c) Floor
Floor is the important part to drain static electricity, which is generated by operators or equipment.
There is a possibility that charged static electricity is not properly drained in case of insulating floor. Set the
electrostatic earth (electrostatic earth: 1x108 ohm).
d) Humidity
Proper humidity helps in reducing the chance of generating electrostatic charges. Humidity should be kept
over
50%RH.
e) Transportation/storage
The storage materials also need to be anti-static treated because there is a possibility that the human body or
storage
materials such as containers may be statically charged by friction or peeling.
The modules should be kept in antistatic bags or other containers resistant to static for storage.
f) Soldering
Solder only to the I/O terminals.Use only soldering irons with proper grounding and no leakage.
Soldering temperature : 280°C ± 10°C
Soldering time: 3 to 4 sec.
Use eutectic solder with resin flux fill.
If flux is used, the LCD surface should be covered to avoid flux spatters. Flux residue should be removed
afterwards.
g) Others
The laminator (protective film) is attached on the surface of LCD panel to prevent it from scratches or stains. It
should
be peeled off slowly using static eliminator.
Static eliminator should also be installed to the workbench to prevent LCD module from static charge.
10. Operation
a) Driving voltage should be kept within specified range; excess voltage shortens display life.
b) Response time increases with decrease in temperature.
c) Display may turn black or dark blue at temperatures above its operational range; this is (however not
pressing on the viewing area) may cause the segments to appear “fractured”.
d) Mechanical disturbance during operation (such as pressing on the viewing area) may cause the
segments to appear “fractured”.
11. If any fluid leaks out of a damaged glass cell, wash off any human part that comes into contact with soap and
water. The toxicity is extremely low but caution should be exercised at all the time.
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
13
ACM1602Z-RN-GBW-C
VER1.0
12. Disassembling the LCD module can cause permanent damage and it should be strictly avoided.
13. LCD retains the display pattern when it is applied for long time (Image retention). To prevent image retention,
do not apply the fixed pattern for a long time. Image retention is not a deterioration of LCD. It will be removed
after display pattern is changed.
14. Do not use any materials, which emit gas from epoxy resin (hardener for amine) and silicone adhesive agent
(dealcohol or deoxym) to prevent discoloration of polarizer due to gas.
15. Avoid the exposure of the module to the direct sunlight or strong ultraviolet light for a long time.
16. The brightness of LCD module may be affected by the routing of CCFL cables due to leakage to the chassis
through coupling effect. The inverter circuit needs to be designed taking the level of leakage current into
consideration. Thorough evaluation is needed for LCD module and inverter built into its host equipment to
ensure specified brightness.
DISPLAYTRONIC XIAMEN ZETTLER ELECTRONICS CO., LTD.
14