ACT ACTF9015/1575.42/DCC6C

Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
The ACTF9015/1575.42/DCC6C is a low-loss, compact, and economical surface-acoustic-wave
(SAW) filter in a surface-mount ceramic DCC6C case designed for GPS applications.
1.Package Dimensions (DCC6C)
2.
Pin
Configuration
2
Input / Output
5
Output / Input
others
Case Ground
Sign
Data (unit: mm)
Sign
Data (unit: mm)
A
0.6
E
1.1
B
1.5
F
3.0
C
1.5
G
3.0
D
1.8
3.Test Circuit
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
1 OF 3
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
4. Frequency Characteristics
5.Performance
5-1.Maximum Ratings
Value
Units
Input Power Level
10
dBm
DC Voltage
0
V
-40 to +85
°C
+235
°C
Rating
Storage Temperature
Soldering Temperature
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
2 OF 3
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
5-2.Electronic Characteristics
Characteristic
Centre Frequency
Min.
fC
Insertion Loss
IL
1574.220 …. 1576.620 MHz
Amplitude Ripple (p-p)
1574.220 …. 1576.620 MHz
Max.
Units
1575.420
MHz
--
1.6
3.5
dB
--
0.3
1.5
dB
40
30
50
45
48
38
66
54
-----
dB
α
Absolute Attenuation
1475.42 MHz
1535.42 MHz
1615.42 MHz
1675.42 MHz
VSWR
Typ.
1574.220 …. 1576.620 MHz
2.0
Input / Output Impedance
50
Ω
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1.
2.
3.
4.
5.
6.
The frequency f C is defined as the midpoint between the 3dB frequencies.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50 Ω test system with VSWR ≤1.2:1. The test fixture L and C are adjusted for minimum insertion
loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on
the impedance matching component values and quality.
Unless noted otherwise, specifications apply over the entire specified operating temperature range.
The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
3 OF 3
Issue : 1 C1
Date : SEPT 04