ACT ACTF410A

Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
ACT part : ACTF410A/410.0/F11
This specification covers the characteristics of the 410.000MHz SAW Filter.
( For Mobile Radio – FRS & PMR )
1. Package Dimension (F-11)
Pin
Configuration
1
Input / Output
4
Output / Input
2/3
Case Ground
Dimensions
Data (unit: mm)
A
11.0±0.3
B
4.5±0.3
C
3.2±0.3
D
0.45±0.1
E
5.0±0.5
F
2.54±0.2
3. Test Circuit
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
4. Typical Frequency Response
5. Performance
5-1.Maximum Ratings
Rating
RF Power Dissipation
Value
P
0dBm
DC Voltage
VDC
10V
AC Voltage
VAC
10V50Hz/60Hz
Operation Temperature
Topr
-20 to +60°C
Storage Temperature
Tstg
-40 to +85°C
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
5-2.Electronic Characteristics
Characteristics
Minimum
Typical
Maximum
Units
Center Frequency
fC
--
410.000
--
MHz
Usable Pass Band
BW
--
±3.0
--
MHz
Insertion Loss
IL
--
3.0
4.5
dB
36
42
42
50
--
dB
--
--
2.0
dB
within fC±3.0MHz
Absolute Attenuation
out of fC -20.0MHz
out of fC -25.0MHz
α
Pass Band Ripple
within fC±3.0MHz
Δα
Input and Output Impedance (Nominal)
50Ω//0pF
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1.
2.
3.
4.
5.
6.
The frequency f C is defined as the midpoint between the 3dB frequencies.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50Ω test system with VSWR≤1.2:1. The test fixture L and C are adjusted for minimum insertion
loss at the filter center frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on
the impedance matching component values and quality.
Unless noted otherwise, specifications apply over the entire specified operating temperature range.
The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04