ARTESYN SMT15E-12V

SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
SMT15E-12V SERIES
0.8 Vin to 3.63 Vin Single output
15 A Current rating
Input voltage range: 10.0 Vdc - 14.0 Vdc
Output voltage range: 0.8 Vdc - 3.63 Vdc
Ultra high efficiency: 94% @ 12 Vin and 3.3 Vout
Extremely low internal power dissipation
Minimal thermal design concerns
Designed in reliability: MTBF of 6,920,000 hours per Telcordia SR-332
Ideal solution where board space is at a premium or tighter card pitch is required
Industry standard surface-mount footprint
Available RoHS compliant
THE SMT15E-12 series are non-isolated
The SMT15E-12 is designed for
dc-dc converters packaged in a single-in-
applications that include distributed
line footprint giving designers a cost
power, workstations, optical network and
effective solution for conversion from a
wireless applications. Implemented using
10 Vdc to 14 Vdc input to output voltages
state of the art surface mount technology
of 0.8 Vdc to 3.63 Vdc. The SMT15E-12
and automated manufacturing techniques,
offers a wide outputs trim range, which
the SMT15E-12 offers compact size and
allows maximum design flexibility and a
efficiencies of up to 94%
pathway for future upgrades.
[ 2 YEAR WARRANTY ]
1
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SXA10 Series
DC/DC
SMT15E Series
| 15| A15W
DC-DC
E Class Non-Isolated DC-DC Converters
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any
other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Absolute Maximum Ratings
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Input voltage - continuous
Vin (cont)
-0.3
14
V DC
Vin(+) - Vin(-)
Input voltage - peak/surge
Vsurge
-0.3
14.5
V DC
2s max, non-repetitive
Operating temperature
Top
-40
85
ºC
Measured at thermal reference
points, see Note 1
Storage temperature
Tstorage
-40
125
ºC
Output power (3.3V)
Pout (max)
49.5
W
All specifications are typical at nominal input Vin = 12V, full load under any resistive load combination at 25˚C unless otherwise stated.
Input Characteristics
Characteristic
Symbol
Min
Typ
Max
Units
Input voltage - operating
Vin (oper)
lin
lin (off)
10
12
14
V DC
Input current - no load
Input current - quiescent
70
7
100
mA DC
mA DC
Vin (min) - Vin (max), enabled
Converter disabled
Inrush current (i2t)
linrush
A2µs
Complies with ETS300 132 Part 4.7,
with recommended LISN
0.1
Input ripple current
Input fuse*
120
Notes and Conditions
6
mA rms
A
Max
Units
10
20
V DC
msec
Slowblow/antisurge HRC
recommended*
*See Application Note 142 for manufacturer and part number
Turn On/Off
Characteristic
Symbol
Input voltage - turn on
Turn on delay - enabled,
then power applied
Vin (on)
Tdelay
(power)
Turn on delay - power
applied, then enabled
Tdelay
(enable)
20
msec
Rise time
Trise
15
msec
2
Min
Typ
Notes and Conditions
With the enable signal asserted,
this is the time from when the
input voltage reaches the
minimum specified operating
voltage until the output voltage
is within the total regulation
band
Vin = Vin (nom), then enabled.
This is the time taken until the
output voltage is within the total
error band
From 10% to 90%; full resistive
load, no external capacitance
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
Signal Electrical Interface
Characteristic - Signal Name Symbol
Min
At remote/control ON/OFF pin
Open collector or equivalent
compatible
Control pin open circuit voltage Vih
High level input current
Iih
High level input voltage
Vih
Acceptable high level
leakage current
Iih (leakage)
Low level input voltage
Low level input current
Typ
Max
0
1
Units
Notes and Conditions
V
See Notes 2 and 3
See Application Note 142 for
Remote ON/OFF details
Iih = 0 µA; open circuit voltage
mA
Current flowing into control pin
when pin is pulled high
(max at Vih - 5.5V)
Vin
Converter guaranteed ON when
control pin is greater than Vih(min)
or open cct.
-10
µA
Acceptable leakage current from
signal pin into the open collector
driver (neg = from converter)
ViI
0.8
V
Converter guaranteed OFF
when control pin is less
than Vil (max) volts or open cct.
IiI
20
µA
Vil = < 0.4 V
Max
Units
Notes and Conditions
1.6
Reliability and Service Life
Characteristic
Symbol
Mean time between failure
MTBF
482,000
Hours
MIL-HDBK-217F,
Vin = Vin (nom); Iout = Iout
(max); ambient 25ºC;
ground benign environment
Mean time between failure
MTBF
6,920,000
Hours
Telcordia SR-332
Mean time between failure
MTBF
Hours
Demonstrated. This entry will be
periodically updated as the
number of test hours increase
3
www.artesyn.com
Min
TBA
Typ
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SXA10 Series
DC/DC
SMT15E Series
| 15| A15W
DC-DC
E Class Non-Isolated DC-DC Converters
Other Specifications
Characteristic
Symbol
Switching frequency
Fsw
Min
Typ
Max
Units
Notes and Conditions
200
kHz
Fixed frequency
Weight
7
g
Coplanarity
100
µm
Measured from seating plane
Max
Units
Notes and Conditions
85
ºC
See Note 5 and individual
derating curves
Environmental Specifications
Characteristic
Symbol
Thermal performance
Min
Typ
-40
EMC
Electromagnetic Compatibility
Phenomenon
Port
Standard
Test level
Criteria
Notes and conditions
6kV contact
8kV air
NP
As per ETS 300 386-1 table 5
Immunity:
Conducted immunity
EN61000-4-6
Radiated immunity
EN61000-4-3
ESD
Enclosure
EN61000-4-2
Performance criteria:
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to
normal performance shall occur at the cessation of the test.
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.
Unit will self recover to normal performance after test.
Referenced ETSI standards:
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)
ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions
4
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
Safety Agency Approvals
Standard
Category
UL/cUL CSA 22.2
UL60950
TÜV Product Service EN60950
File No. E174104
Certificate No. B 02 12 382 72 035
Material Ratings
Characteristic
Notes and Conditions
Flammability rating
UL94V-0
Model Numbers
Model
Number
SMT15E-12W3V3J
Input
Output
Output Current
Typical
Max. Load
Voltage
Voltage
(Max.)
Efficiency
Regulation
10.0-14.0 Vdc
0.8-3.63 Vdc
15 A
93% @ full load
±1.0%
RoHS Compliance Ordering Information
The ‘J’ at the end of the part number
indicates that the part is Pb-free
(RoHS 6/6 compliant). TSE RoHS 5/6
(non Pb-free) compliant versions may
be available on special request, please
contact your local sales representative
for details.
5
www.artesyn.com
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SXA10 Series
DC/DC
SMT15E Series
| 15| A15W
DC-DC
E Class Non-Isolated DC-DC Converters
W3V3 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
4.4
4.5
A DC
Vin = Vin (nom); Iout = Iout
(max.); Vo = Vo (nom)
Reflected ripple current
Iin (ripple)
120
mA rms
Iout = Iout (max.), measured
without external filter
Input capacitance internal filter
Cinput
18.8
µF
Internal to converter
Input capacitance external bypass
Cbypass
100
µF
Recommended customer
added capacitance may be
required on source impedance
on customers applications
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vo (nom)
0.785
0.8
0.815
V DC
Vin = Vin (nom); Iout = Iout (nom)
Total regulation band
Vo
%
For all line, static load and
temperature until end of life
W3V3 Model
Electrical Characteristics - O/P
3
Line regulation
1
%
Iout = Iout (nom);
Vin (min) to Vin (max)
Load regulation
1
%
Vin = Vin (nom);
Iout (min) to Iout (max)
15
A DC
20
A rms
Output current continuous
Iout
Output current - short circuit
Isc
0
10
Continuous, unit auto recovers
from short, Vo < 100mV
Output voltage - noise
6
Vp-p
Vrms
80
25
mV pk-pk Measurement bandwidth:
20MHz. See Application Note
mV rms
142 for measurement set-up
details
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
W3V3 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Load transient response peak deviation
Vdynamic
Load transient response recovery
Trecovery
External load capacitance
Cext
0
Symbol
Min
Typ
Max
Units
Notes and Conditions
100
mV
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec.
Measurement taken with no
external capacitors
100
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load. Measurement
taken with no external
capacitors
10,000
µF
Max
Units
Notes and Conditions
3.63
V
Trim up. Note that the maximum
output power is still 49.5W.
De-rate the maximum output
current accordingly
10
%
Max
Units
Notes and Conditions
W3V3 Model
Protection and Control Features
Characteristic
Allowable output voltage
Typ
0.8
Open sense voltage
W3V3 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
92
93
%
Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency
η
93
94
%
Iout = 50% Iout (max),
Vin = Vin (nom)
7
www.artesyn.com
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SXA10 Series
DC/DC
SMT15E Series
| 15| A15W
DC-DC
E Class Non-Isolated DC-DC Converters
95
100
91
80
60
0 m/s (0 LFM)
1 m/s (200 LFM)
2 m/s (400 LFM)
40
20
0
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE (ºC)
8
EFFICIENCY (%)
RATED OUTPUT POWER (%)
W3V3 Model
87
Vin = 10.0V
Vin = 12.0V
Vin = 14.0V
83
79
75
1
3
5
7
9
11
13
15
OUTPUT CURRENT (A)
Figure 1: Derating Curve
with Vin = 12V and No Trim (Vout = 0.8V)
Figure 2: Efficiency vs Load
Figure 3: Short Circuit Characteristic
(Channel 4: Is/c)
Figure 4: Typical Transient Response 50% - 75%
Step Load Change (Channel 2: Vo, Channel 4: Io)
Figure 5: Typical Transient Response 75% - 50%
Step Load Change (Channel 2: Vo, Channel 4: Io)
Figure 6: Typical Power-up Characteristic
(Channel 1: Vin, Channel 2: Vo)
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
W3V3 Model
Figure 7: Control On/Off Characteristic
(Channel 1: Vo, Channel 2: Remote ON/OFF)
9
www.artesyn.com
Figure 8: Typical Ripple and Noise
Vin = 12V, Vout = 3V3 and Iout = 15A (Channel 1: Vo)
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SXA10 Series
DC/DC
SMT15E Series
| 15| A15W
DC-DC
E Class Non-Isolated DC-DC Converters
TOP VIEW
0.039 (1.00)
0.530 ±0.010
(13.46 ± 0.25)
0.039 (1.00)
BOTTOM VIEW
4
3
0.405 (10.29)
0.430 (10.92)
5
0.297
(7.54)
2
1
6
SIDE VIEW
0.048 (1.22)
0.323 (8.21)
Installed Ht.
0.007 (0.18)
Min Clearance
0.075 (1.91)
0.310
(7.87)
1.300±0.010 (33.02 ±0.25)
0.190
(4.83) 0.190
(4.83) 0.190
(4.83)
Seating Plane
All dimensions in inches (mm)
All tolerance ±0.010in (±0.25mm)
unless otherwise stated
Max. component
Connector (6PL)
Width :0.112 ± 0.003 (2.84 ± 0.08)
Length: 0.062 ± 0.002 (1.57 ± 0.04)
Pin Connections
Pin No.
Function
1
2
3
4
5
6
Remote ON/OFF
Remote Sense +
Trim
+Vout
Ground
+Vin
Figure 9: Mechanical Drawing and Pinout Table
10
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
Note 1
Thermal reference is defined as the highest temperature
measured at any one of the specified thermal reference points.
See Figure 10: Thermal reference points.
Case Temperature should not exceed 115ºC
Note 2
The Remote ON/OFF pin is referenced to ground.
Note 3
The SMT15E-12 features an ‘Active High’ Remote ON/OFF
operation. If not using the Remote ON/OFF pin, leave the pin
open (the converter will be on). The Remote ON/OFF pin is
referenced to ground.
The following conditions apply for the SMT15E:
Configuration
Remote pin open circuit
Remote pin pulled low [Von/off <.8V]
Remote pin pulled high [Von/off >1.6V]
Converter Operation
Unit is ON
Unit is OFF
Unit is ON
Direction of Airflow
A an ‘Active Low’ Remote ON/OFF version is also possible
with this converter. Please consult the factory for details.
Figure 10: Thermal Reference Points
Note 4
Thermal reference set up: Unit mounted on an edge card test
board 203mm x 190mm. Test board mounted vertically. For test
details and recommended set-up see Application Note 142.
Note 5
Max 60ºC for full load in still air. See Application Note 142 for a
detailed thermal Derating.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is accessible only to trained personnel. The user
must provide the recommended fusing in order to comply with
safety approvals.
11
www.artesyn.com
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006
SMT15E Series | 15 A DC-DC
E Class Non-Isolated DC-DC Converters
NORTH AMERICA
e-mail: [email protected]
% 800 769 7274
%+ 508 628 5600
EUROPEAN LOCATIONS
e-mail: [email protected]
IRELAND
%+ 353 24 93130
AUSTRIA
%+ 43 1 80150
FAR EAST LOCATIONS
e-mail: [email protected]
HONG KONG
%+ 852 2699 2868
Longform Datasheet  Artesyn Technologies® 2006
The information and specifications contained in this datasheet are
believed to be correct at time of publication. However, Artesyn
Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to
change without notice. No rights under any patent accompany the
sale of any such product(s) or information contained herein.
12
www.artesyn.com
File Name: lf_smt15e_12.pdf Rev (02): 04 Jan 2006