ARTESYN CXE15

CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC Converters
CXE15 48V SERIES
Single output
High efficiency topology, 87% typical at 5V
Industry standard footprint
Wide operating temperature, up to and exceeding +70˚C (natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote on/off
Approvals to EN60950 and UL/cUL1950
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 (input voltage and current requirements)
Complies with ETS 300 386-1
The CXE15 is a new high efficiency open
protection features are included as
frame isolated 15 Watt converter series in
standard. With full international safety
an industry standard footprint. The first
approval including EN60950 and
four models in the series feature an input
cUL1950, the CXE15 reduces compliance
voltage range of 33 to 75VDC and are
costs and time to market.
available in output voltages of 5V, 3.3V,
2.5V and 1.8V. The output voltage on
each model is adjustable from 90% to
110% of the nominal value. Typical
efficiencies for the models are 87% for the
5V, 86% for the 3.3V, 85% for the 2.5V
and 83% for the 1.8V version. The CXE15
series also has a remote on/off capability,
with active 'HI' or active 'LO' logic options
available. Overcurrent and overvoltage
[ 2 YEAR WARRANTY ]
TÜV
1
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any
other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Absolute Maximum Ratings
Characteristic
Symbol
Min
Input voltage - continuous
Vin (cont)
Input voltage - peak/surge
Typ
Max
Units
Notes and Conditions
-0.3
75
V DC
Vin(+) - Vin(-)
Vsurge
-0.3
80
V DC
2s max, non-repetitive
Operating temperature
Top
-40
115
ºC
Measured at thermal reference
points, see Note 1
Storage temperature
Tstorage
-40
120
ºC
Output power (1.8V)
Pout (max)
10.8
W
Output power (2.5V)
Pout (max)
15
W
Output power (3.3V)
Pout (max)
15
W
Output power (5V)
Pout (max)
15
W
All specifications are typical at nominal input Vin = 48V, full load under any resistive load combination at 25˚C unless otherwise stated.
Input Characteristics
Characteristic
Symbol
Min
Typ
Max
Units
Input voltage - operating
33
48
75
V DC
Input current - no load
Input current - Quiescent
Vin (oper)
lin
lin (off)
28
20
35
25
mADC
mADC
Vin (min) - Vin (max), enabled
Converter disabled
Input voltage variation
dv/dt
5
V/ms
Complies with ETS300 132 Part 4.4
µA s
Complies with ETS300 132 Part 4.7,
with recommended LISN
Inrush current (i t)
linrush
300
Inrush current ratio
It/Im
19.5
2
Input ripple rejection
Input fuse
2
45
2
dB
A
Notes and Conditions
Complies with ETS300 132 Part 4.7,
with recommended LISN
Frequency <1 kHz
Slowblow/antisurge HRC
recommended, 200V rating
Turn On/Off
Characteristic
Symbol
Min
Typ
Max
Units
Input voltage - turn on
Vin (on)
30
33
36
V DC
Input voltage - turn off
Vin (off)
27
30
33
V DC
Hysteresis
Turn on delay - enabled,
then power applied
Tdelay
(power)
3
1.5
4
V DC
msec
Turn on delay - power
applied, then enabled
Tdelay
(enable)
2.5
4
msec
Rise time
Trise
0.6
1
msec
2
Notes and Conditions
With the enable signal asserted,
this is the time from when the
input voltage reaches the
minimum specified operating
voltage until the output voltage
is within the total regulation
band
Vin = Vin (nom), then enabled.
This is the time taken until the
output voltage is within the total
error band
From 10% to 90%; full resistive
load, no external capacitance
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
Signal Electrical Interface
Characteristic - Signal Name Symbol
Min
At remote/control ON/OFF pin
Open collector or equivalent
compatible
Control pin open circuit voltage Vih
Typ
12
Max
Units
Notes and Conditions
13
V
See Notes 2 and 3
See Application Note 116 for
Remote On/Off details
Iih = 0 µA; open circuit voltage
High level input current
Iih
10
µA
Current flowing into control pin
when pin is pulled high
(max. at Vih = 75V)
Acceptable high level
leakage current
Iih (leakage)
-50
µA
Acceptable leakage current from
signal pin into the open collector
driver (neg = from converter)
Low level input voltage
ViI
1.2
V
Converter guaranteed off
when control pin is
less than Vil (max)
Low level input current
IiI
mA
Vil = 0.4 V
Low level input current
Iil (max)
-1.5
mA
ViI = 0.0 V;
Max
Units
Notes and Conditions
0
-1.4
Reliability and Service Life
Characteristic
Symbol
Min
Typ
Mean time between failure
MTBF
600,000
Hours
MIL-HDBK-217F,
Vin = Vin (nom); Iout = Iout
(max); ambient 25ºC;
ground benign environment
Mean time between failure
MTBF
1,000,000
Hours
per Bellcore TR-NWT-000332
Issue 3, ground benign,
temp. = 40ºC, Vin = Vin (nom),
Iout = Iout (max)
Mean time between failure
MTBF
TBD
Hours
Demonstrated. This entry will be
periodically updated as the
number of test hours increase
Expected service life
Years
Isolation
Characteristic
Symbol
Min
Typ
Input to output test voltage
Input to output capacitance
Input to output resistance
Input to output insulation system
3
www.artesyn.com
1000
100
Max
Units
Notes and Conditions
1500
V DC
Test duration 1s
pF
MΩ
Operational
Measured with 500 V DC
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
Other Specifications
Characteristic
Symbol
Switching frequency
Fsw
Min
Weight
Typ
Max
Units
Notes and Conditions
265
kHz
Fixed frequency
12
g
Environmental Specifications
Characteristic
Symbol
Thermal performance
1V8 and 2V5 models
3V5 and 5V models
Min
Typ
Max
Units
Notes and Conditions
-40
-40
70
65
ºC
ºC
See Notes 1, 4 and
individual derating curves
Type
Parameter
Reference
Test Level
Notes and Conditions
Air temperature
Low
High
Change
IEC 68-2-1
IEC 68-2-2
IEC 68-2-14
-40ºC
+70ºC
-40ºC to +70ºC
All characteristics and parameters
extracted from ETS 300 019
classes 3.1, 3.2, 3.3, 3.4 and 3.5
Tmax. = +70˚C for T3.4
Relative humidity
Low
High
Condensation
IEC 68-2-56
IEC 68-2-30
10%
100%
90 to 100%
Vibration IEC Class 3M5
Freq. velocity
IEC 68-2-6
Freq. acceleration IEC 68-2-6
5-9Hz 5mm/s
9-200Hz 1g
Shocks IEC Class 3M5
Acceleration
10g
IEC 68-2-29
Referenced ETSI standards:
ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment
ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations
ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations
EMC
Electromagnetic Compatibility
Phenomenon
Port
Standard
Test level
Criteria
Notes and conditions
ESD
Enclosure
EN61000-4-2
6kV contact
8kV air
As per ETS 300 386-1 table 5
EFT
DC power
EN61000-4-4
As per ETS 300 386-1 table 5
Signal
EN61000-4-4
2kV
4kV
1kV
2kV
Radiated field
Enclosure
EN61000-4-3
10V/m
As per ETS 300 386-1 table 5
Conducted
DC power
Signal
EN61000-4-6
EN61000-4-6
10V
10V
As per ETS 300 386-1 table 5
Signal line assumed < 3m in length
Input transients
DC power
Immunity:
4
As per ETS 300 386-1 table 5
ETS 300 132, ETR 283
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
EMC
Electromagnetic Compatibility
Phenomenon
Port
Standard
Test level Criteria
Notes and conditions
DC power
EN55022
Level A
EN55022
Level B
EN55022
Level B
With recommended external filter for
compliance bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1. See Application
Note 116 for details
With recommended external filter for
compliance bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1. See Application
Note 116 for details
Bandwidth 150kHz to 30MHz,
as per ETS 300 386-1
EN55022
Level B
Emission:
Conducted
Signal
Radiated
Bandwidth 30 MHz to 1 GHz, as per
ETS 300 386-1
Performance criteria:
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to
normal performance shall occur at the cessation of the test.
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.
Unit will self recover to normal performance after test.
Referenced ETSI standards:
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)
ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions
Standards Compliance List
Standard
Category
EN60950
UL/cUL 1950
TÜV Rheinland
2000
3rd edition
EN60950:2000
Safety Agency Approvals
Characteristic
UL/cUL 1950 File Number
TÜV Rheinland Certificate No.
E135734
R2074133
Material Ratings
Characteristic - Signal Name Notes and Conditions
Flammability rating
Material type
UL94V-0
FR4 PCB
Model Numbers
Model
Number
Input
Voltage
CXE15-48S1V8
CXE15-48S2V5
CXE15-48S3V3
CXE15-48S05
5
www.artesyn.com
33-75
33-75
33-75
33-75
VDC
VDC
VDC
VDC
Output
Voltage
Overvoltage
Protection
Output Current
(Max.)
Typical
Efficiency
Max. Load
Regulation
1.8V
2.5V
3.3V
5.0V
2.3V
3.2V
4.0V
6.0V
6.0A
6.0A
4.5A
3.0A
83%
85%
86%
87%
2.0%
1.5%
0.5%
0.5%
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S1V8 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.271
0.274
A DC
Vin = Vin (nom); Iout = Iout
(max.); Vo = Vo (nom)
Input current - maximum
Iin (max.)
0.399
0.404
A DC
Vin = Vin (min); Iout = Iout
(max.); Vo = Vo (nom)
(measured at converter)
Reflected ripple current
Iin (ripple)
1.8
5
mA RMS Iout = Iout (max.), measured
mA pk-pk with external filter. See
Application Note 116 for details
Input capacitance - internal
filter
Cinput
1.5
µF
Internal to converter
Input capacitance - external
bypass
Cbypass
0
µF
Recommended customer
added capacitance
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vo (nom)
1.76
1.80
1.84
V DC
Vin = Vin (nom); Iout = Iout (nom)
Worst case condition over line,
load, temperature and life
Total regulation band
Vo
1.74
1.86
V DC
For all line, static load and
temperature until end of life.
Line regulation
0.5
%
Iout = Iout (nom); Vin (min)
to Vin (max)
Load regulation
2.0
%
Vin = Vin (nom); Iout (min) to
Iout (max)
6.0
A DC
CXE15-48S1V8 Model
Electrical Characteristics - O/P
Output current continuous
Iout
Output current - short circuit
Isc
10
12
A rms
Output voltage - noise
Vp-p
Vrms
40
14
70
20
mV pk-pk Measurement bandwidth 20 MHz
mV rms
See Application Note 116 for
measurement set-up details
6
0.00
Continuous, unit auto recovers
from short, Vo < 100mV
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
CXE15-48S1V8 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Load transient response peak deviation
Vdynamic
Load transient response recovery
Trecovery
External load capacitance
Cext
0
Characteristic
Symbol
Min
Overvoltage clamp voltage
Vov
2.2
Overcurrent limit inception
Ioc
Typ
Max
Units
Notes and Conditions
150
mV
Peak deviation for 50% to 75%
step load, di/dt = 100mA/µsec
400
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
10,000
µF
Max
Units
Notes and Conditions
3.0
V DC
Non-latching. Refer to
Application Note 116 for details
8.4
A DC
Vo = 90% of Vo (nom)
110
%
%
Trim up (% of Vo nom)
Trim down (% of Vo nom)
See Application Note 116 for
details of trim equations and
trim curves
V DC
No sense option
Units
Notes and Conditions
CXE15-48S1V8 Model
Protection and Control Features
Typ
7.5
Output voltage trim range
90
Open sense voltage
CXE15-48S1V8 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
82
83
%
Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency
η
78
80
%
Iout = 50% Iout (max),
Vin = Vin (nom)
7
www.artesyn.com
Max
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S2V5 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.367
0.372
ADC
Vin = Vin (nom);
Iout = Iout (max.); Vo = Vo (nom)
Input current - maximum
Iin (max.)
0.541
0.548
ADC
Vin = Vin (min);
Iout = Iout (max.); Vo = Vo (nom)
Reflected ripple current
Iin (ripple)
1.8
5
mA RMS Iout = Iout (max.), measured
mA pk-pk with external filter. See
Application Note 116 details
Input capacitance internal filter
Cinput
1.5
µF
Internal to converter
Input capacitance External bypass
Cbypass
0
µF
Recommended customer
added capacitance
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vo (nom.)
2.44
2.50
2.56
VDC
Vin = Vin (nom); Iout = Iout (nom)
Worst case condition over line,
load, temperature and life
Total regulation band
Vo
2.42
2.58
VDC
For all line, static load and
temperature until end of life
Line regulation
0.5
%
Iout = Iout (nom);
Vin (min) to Vin (max)
Load regulation
1.5
%
Vin = Vin (nom);
Iout (min) to Iout (max)
6
ADC
CXE15-48S2V5 Model
Electrical Characteristics - O/P
Output current continuous
Iout
Output current - short circuit
Isc
10
12
A RMS
Output voltage - noise
Vp-p
Vrms
40
14
70
20
mV pk-pk Measurement bandwidth 20 MHz
mV rms
See Application Note 116 for
set-up details
8
0.00
Continuous, unit auto recovers
from short, Vo < 100mV
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
CXE15-48S2V5 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Load transient response peak deviation
Vdynamic
Load transient response recovery
Trecovery
External load capacitance
Cext
0
Characteristic
Symbol
Min
Overvoltage clamp voltage
Vov
2.7
Overcurrent limit inception
Ioc
Typ
Max
Units
Notes and Conditions
150
mV
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec
400
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
10,000
µF
Max
Units
Notes and Conditions
3.75
V DC
Non-latching
Refer to Application Note 116
8.4
A DC
Vo = 90% of Vo (nom)
110
%
Trim up (% of Vo nom). Note
that the maximum output power
is still 15W. Derate the
maximum output current
accordingly
Trim down (% of Vo nom)
See Application Note 116 for
details of trim equations and
trim curves
CXE15-48S2V5 Model
Protection and Control Features
Typ
7.5
Allowable output voltage
trim range
90
%
Open sense voltage
V DC
No sense function
Units
Notes and Conditions
CXE15-48S2V5 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
84
85
%
Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency
η
81
83
%
Iout = 50% Iout (max),
Vin = Vin (nom)
9
www.artesyn.com
Max
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S3V3 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.360
0.364
A DC
Vin = Vin (nom); Iout = Iout
(max.); Vo = Vo (nom)
Input current - maximum
Iin (max.)
0.529
0.536
A DC
Vin = Vin (min); Iout = Iout
(max.); Vo = Vo nom (measured
at converter)
Reflected ripple current
Iin (ripple)
1.8
5
mA RMS Iout = Iout (max.), measured
mA pk-pk with external filter. See
Application Note 116 details
Input capacitance internal filter
Cinput
1.5
µF
Internal to converter
Input capacitance external bypass
Cbypass
0
µF
Recommended customer
added capacitance
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vo (nom)
3.24
3.30
3.38
V DC
Vin = Vin (nom); Iout = Iout (nom)
Worst case condition over line,
load, temperature and life
Total regulation band
Vo
3.19
3.41
V DC
For all line, static load and
temperature until end of life
Line regulation
0.10
%
Iout = Iout (nom);
Vin (min) to Vin (max)
Load regulation
0.50
%
Vin = Vin (nom);
Iout (min) to Iout (max)
4.5
A DC
CXE15-48S3V3 Model
Electrical Characteristics - O/P
Output current continuous
Iout
Output current - short circuit
Isc
8.0
10
A rms
Output voltage - noise
Vp-p
Vrms
70
20
100
35
mV pk-pk Measurement bandwidth:
mV rms
20 MHz. See Application Note
116 for measurement set-up
details
10
0.00
Continuous, unit auto recovers
from short, Vo < 100mV
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
CXE15-48S3V3 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Load transient response peak deviation
Vdynamic
Load transient response recovery
Trecovery
External load capacitance
Cext
0
Characteristic
Symbol
Min
Overvoltage clamp voltage
Vov
3.6
Overcurrent limit inception
Ioc
Typ
Max
Units
Notes and Conditions
100
mV
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec
400
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
10,000
µF
Max
Units
Notes and Conditions
5.0
V DC
Non-latching
Refer to Application Note 116
6.3
A DC
Vo = 90% of Vo (nom)
110
%
Trim up (% of Vo nom). Note
that the maximum output power
is still 15W. Derate the
maximum output current
accordingly
Trim down (% of Vo nom)
See Application Note 116 for
details of trim equations and
trim curves
CXE15-48S3V3 Model
Protection and Control Features
Typ
5.6
Allowable output voltage
trim range
90
%
Open sense voltage
V DC
No sense function
CXE15-48S3V3 Model
Efficiency
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Efficiency
η
85
86
-
%
Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency
η
83
85
-
%
Iout = 50% Iout (max),
Vin = Vin (nom)
11
www.artesyn.com
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S05 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.359
0.364
ADC
Vin = Vin (nom);
Iout = Iout (max.); Vo = Vo (nom)
Input current - maximum
Iin (max.)
0.529
0.541
ADC
Vin = Vin (min);
Iout = Iout (max.); Vo = Vo (nom)
Reflected ripple current
Iin (ripple)
-
1.4
5.0
mA RMS Iout = Iout (max.), measured
mA pk-pk with external filter. See
Application Note 116 details
Input capacitance internal filter
Cinput
1.5
µF
Internal to converter
Input capacitance External bypass
Cbypass
0
µF
Recommended customer
added capacitance
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vo (nom.)
4.90
5.00
5.10
VDC
Vin = Vin (nom); Iout = Iout (nom)
Worst case condition over line,
load, temperature and life
Total regulation band
Vo
4.83
5.17
VDC
For all line, static load and
temperature until end of life
0.1
%
Iout = Iout (nom);
Vin (min) to Vin (max)
0.5
%
Vin = Vin (nom);
Iout (min) to Iout (max)
3
ADC
CXE15-48S05 Model
Electrical Characteristics - O/P
Line regulation
Load regulation
0.3
Output current continuous
Iout
Output current - short circuit
Isc
5.5
7.0
A RMS
Output voltage - noise
Vp-p
Vrms
70
20
100
35
mV pk-pk Measurement bandwidth 20 MHz
mV rms
See Application Note 116 for
set-up details
12
0.00
Continuous, unit auto recovers
from short, Vo < 100mV
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
CXE15-48S05 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Load transient response peak deviation
Vdynamic
Load transient response recovery
Trecovery
External load capacitance
Cext
0
Characteristic
Symbol
Min
Overvoltage clamp voltage
Vov
5.5
Overcurrent limit inception
Ioc
Typ
Max
Units
Notes and Conditions
100
mV
Peak deviation for 50% to 75%
step load, di/dt = 100mA/µsec
400
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
10,000
µF
Max
Units
Notes and Conditions
7.2
V DC
Non-latching
Refer to Application Note 116
4.2
A DC
Vo = 90% of Vo (nom)
110
%
Trim up (% of Vo nom). Note
that the maximum output power
is still 15W. Derate the
maximum output current
accordingly
Trim down (% of Vo nom)
See Application Note 116 for
details of trim equations and
trim curves
CXE15-48S05 Model
Protection and Control Features
Typ
3.7
Allowable output voltage
trim range
90
%
Open sense voltage
V DC
No sense function
Units
Notes and Conditions
CXE15-48S05 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
86
87
%
Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency
η
82
84
%
Iout = 50% Iout (max),
Vin = Vin (nom)
13
www.artesyn.com
Max
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S1V8 Model
OUTPUT CURRENT (%)
120
100
80
33Vin - 75Vin
<60Vin
60
40
20
0
-40
OUTPUT CURRENT (A)
6.5
6
Natural
Convection
Simulation
100LFM
200LFM
300LFM
5.5
5
400LFM
4.5
4
3.5
3
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
25
100
Figure 1: Output Current vs Temperature
(Still Air)
55
35
45
65
75
AMBIENT TEMPERATURE (˚C)
85
Figure 2: Output Current vs Temperature
with Forced Air Cooling
1.6
1.2
Low Line
Nom Line
High Line
0.8
0.4
EFFICIENCY (%)
OUTPUT VOLTAGE (V)
2.0
0.0
0
2
4
6
8
10
12
83.5
83.0
82.5
82.0
81.5
81.0
80.5
80.0
79.5
79.0
78.5
33.9
42.2
OUTPUT CURRENT (A)
85
100% Load
50% Load
25% L0ad
70
65
60
-40
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
100
Figure 5: Typical Efficiency vs Ambient Temperature
14
EFFICIENCY (%)
EFFICIENCY (%)
90
75
75.1
Figure 4: Efficiency vs Line
Figure 3: V-1 Characteristic Over Input Line
80
50.4
58.6
66.8
INPUT VOLTAGE (V)
90
80
70
60
50
40
30
20
10
0
Low Line
Nom Line
High Line
0
1
2
3
4
5
OUTPUT CURRENT (A)
Figure 6: Efficiency vs Load
6
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
2.0
1.5
1.0
0.5
0.0
Low Line
Nom Line
High Line
Signal
0
2
4
6
TIME (mSec)
8
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
CXE15-48S1V8 Model
2.0
1.5
1.0
0.5
0.0
0
10
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
TIME (mSec)
VOLTAGE (10mV/Div)
Figure 9: Typical Transient Response 50%-75%
Step Load Change
TIME (2.0 µSec/Div)
Figure 11: Typical Ripple and Noise Measurement
15
www.artesyn.com
1
2
3
TIME (mSec)
4
5
Figure 8: Control On/Off Characteristic
Figure 7: Typical Power-up Characteristic
0.05
0.00
-0.05
-0.10
-0.15
Low Line
Nom Line
High Line
Signal
0.15
0.10
0.05
0.00
-0.05
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
Figure 10: Typical Transient Response 75%-50%
Step Load Change
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S2V5 Model
120
100
80
33Vin - 75Vin
<60Vin
60
40
20
0
-40
OUTPUT CURRENT (A)
OUTPUT CURRENT (%)
6.5
6
Natural
Convection
Simulation
100LFM
200LFM
300LFM
5.5
5
400LFM
4.5
4
3.5
3
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
55
35
45
65
75
AMBIENT TEMPERATURE (˚C)
25
100
85
Figure 13: Output Current vs Temperature
with Forced Air Cooling
Figure 12: Output Current vs Temperature
(Still Air)
2.5
2.0
Low Line
Nom Line
High Line
1.5
1.0
0.5
EFFICIENCY (%)
OUTPUT VOLTAGE (V)
3.0
0.0
0
2
4
6
8
10
12
85.5
85.0
84.5
84.0
83.5
83.0
82.5
82.0
81.5
33.9
42.1
OUTPUT CURRENT (A)
Figure 14: V-1 Characteristic Over Input Line
100% Load
50% Load
25% L0ad
70
65
60
-40
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
100
Figure 16: Typical Efficiency vs Ambient Temperature
16
EFFICIENCY (%)
EFFICIENCY (%)
85
75
75.0
Figure 15: Efficiency vs Line
90
80
50.4
58.6
66.8
INPUT VOLTAGE (V)
90
80
80
60
50
40
30
20
10
0
Low Line
Nom Line
High Line
0
1
2
3
4
5
OUTPUT CURRENT (A)
Figure 17: Efficiency vs Load
6
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
CXE15-48S2V5 Model
3.0
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
3.0
2.0
1.0
Low Line
Nom Line
High Line
Signal
0.0
0
2
4
6
TIME (mSec)
8
2.0
1.0
10
0.0
0.2
0.3
TIME (mSec)
0.4
0.5
OUTPUT VOLTAGE (V)
Figure 19: Control On/Off Characteristic
0.15
0.10
0.05
0.00
-0.05
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
Figure 20: Typical Transient Response 50%-75%
Step Load Change
Figure 21: Typical Transient Response 75%-50%
Step Load Change
TIME (2.0 µSec/Div)
Figure 22: Typical Ripple and Noise Measurement
17
0.1
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
VOLTAGE (10mV/Div)
OUTPUT VOLTAGE (V)
Figure 18: Typical Power-up Characteristic
0.05
0.00
-0.05
-0.10
-0.15
Low Line
Nom Line
High Line
Signal
0.0
www.artesyn.com
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S3V3 Model
OUTPUT CURRENT (%)
100
80
33Vin - 75Vin
<60Vin
60
40
20
0
-40
-20
0
20
40
60
80
OUTPUT CURRENT (A)
5
120
4.5
Natural
Convection
Simulation
100LFM
200LFM
300LFM
4
3.5
400LFM
3
2.5
2
1.5
100
55
35
45
65
75
AMBIENT TEMPERATURE (˚C)
25
AMBIENT TEMPERATURE (°C)
Figure 23: Output Current vs Temperature
(Still Air)
85
Figure 24: Output Current vs Temperature
with Forced Air Cooling
3.0
87.0
2.5
Low Line
Nom Line
High Line
2.0
1.5
1.0
0.5
EFFICIENCY (%)
OUTPUT VOLTAGE (V)
3.5
0.0
2
0
4
6
8
86.5
86.0
85.5
85.0
84.5
84.0
33.9
10
42.1
OUTPUT CURRENT (A)
90
100
85
80
80
100% Load
50% Load
25% L0ad
75
70
65
60
-40
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
100
Figure 27: Typical Efficiency vs Ambient Temperature
18
75.0
Figure 26: Efficiency vs Line
EFFICIENCY (%)
EFFICIENCY (%)
Figure 25: V-1 Characteristic Over Input Line
50.4
58.6
66.8
INPUT VOLTAGE (V)
60
Low Line
Nom Line
High Line
40
20
0
0.0
0.8
1.5
2.2
3.0
3.7
OUTPUT CURRENT (A)
Figure 28: Efficiency vs Load
4.5
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
4.0
3.0
2.0
1.0
0.0
Low Line
Nom Line
High Line
Signal
0
2
4
6
TIME (mSec)
8
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
CXE15-48S3V3 Model
4
3
2
1
0
Low Line
Nom Line
High Line
Signal
10
0
Figure 29: Typical Power-up Characteristic
4
5
OUTPUT VOLTAGE (V)
Figure 30: Control On/Off Characteristic
0.10
0.08
0.06
0.04
0.02
0.00
-0.02
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
Figure 31: Typical Transient Response 50%-75%
Step Load Change
Figure 32: Typical Transient Response 75%-50%
Step Load Change
TIME (2.0 µSec/Div)
Figure 33: Typical Ripple and Noise Measurement
19
2
3
TIME (mSec)
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
VOLTAGE (10mV/Div)
OUTPUT VOLTAGE (V)
0.02
0.00
-0.02
-0.04
-0.06
-0.08
1
www.artesyn.com
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
CXE15-48S05 Model
100
80
33Vin - 75Vin
<60Vin
60
40
20
0
-40
-20
0
20
40
60
80
OUTPUT CURRENT (A)
OUTPUT CURRENT (%)
3.5
120
3
Natural
Convection
Simulation
100LFM
200LFM
300LFM
2.5
2
400LFM
1.5
1
0.5
0
100
25
AMBIENT TEMPERATURE (°C)
55
35
45
65
75
AMBIENT TEMPERATURE (˚C)
85
Figure 35: Output Current vs Temperature
with Forced Air Cooling
Figure 34: Output Current vs Temperature
(Still Air)
5.0
88.5
4.0
Low Line
Nom Line
High Line
3.0
2.0
1.0
EFFICIENCY (%)
OUTPUT VOLTAGE (V)
6.0
0.0
6
4
2
OUTPUT CURRENT (A)
0
88.0
87.5
87.0
86.5
86.0
85.5
85.0
32.9
8
41.3
100
85
80
100% Load
50% Load
25% L0ad
70
65
60
-40
60
Low Line
Nom Line
High Line
40
20
0
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
100
Figure 38: Typical Efficiency vs Ambient Temperature
20
EFFICIENCY (%)
EFFICIENCY (%)
90
75
75.0
Figure 37: Efficiency vs Line
Figure 36: V-1 Characteristic Over Input Line
80
49.8
58.2
66.6
INPUT VOLTAGE (V)
0.0
0.5
1.0
1.5
2.0
2.5
OUTPUT CURRENT (A)
Figure 39: Efficiency vs Load
3.0
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
CXE15-48S05 Model
6.0
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
6.0
4.0
2.0
Low Line
Nom Line
High Line
Signal
0.0
0
2
4
6
TIME (mSec)
8
4.0
2.0
0.0
10
0.4
0.5
OUTPUT VOLTAGE (V)
0.08
0.06
0.04
0.02
-0.00
-0.02
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
Figure 42: Typical Transient Response 50%-75%
Step Load Change
Figure 43: Typical Transient Response 75%-50%
Step Load Change
VOLTAGE (10mV/Div)
OUTPUT VOLTAGE (V)
0.2
0.3
TIME (mSec)
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
TIME (mSec)
TIME (2.0 µSec/Div)
Figure 44: Typical Ripple and Noise Measurement
21
0.1
Figure 41: Control On/Off Characteristic
Figure 40: Typical Power-up Characteristic
0.02
0.00
-0.02
-0.04
-0.06
-0.08
Low Line
Nom Line
High Line
Signal
0.0
www.artesyn.com
DC/DC
| 15W
CXE15 Single Series | SXA10
10.8Series
to 15W
DC/DC
High Efficiency DC/DC converters
TOP VIEW
Dimensions in Inches [mm]
1.000 (25.40)
2.000 (50.80)
0.015 (0.38)
0.350 (8.89)
SIDE VIEW
0.600 (15.24)
0.040 (1.02)
0.120 (3.05)
0.600 (15.24)
0.800 (20.32)
Recommended Hole Pattern
0.800 (20.32)
0.100
(2.54)
0.200
(5.08)
0.800 (20.32)
3
Case Outline
6
4
0.400 (10.16)
BOTTOM VIEW
5
1
0.400 (10.16)
0.200 (5.08)
4
0.300 (7.62)
3
0.040 (1.016)
0.400 (10.16)
6
Standoff (4 places)
0.600 (15.24)
0.10
(2.54)
Pin Connections
Pin No.
Function
1
2
3
4
5
6
Vin Vin+
On/Off (Optional)
Vout +
Trim (Optional)
Vout -
Figure 45: Dimensions and Pinout
22
0.400 (10.16)
1
.200(5.08) .560 (14.22) 5
.060 (1.52)
2
2
0.200 (5.08)
Plated Through Hole
0.052-0.06 (1.321-1.40) typical
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
Note 1
Hot spot temperature is defined as the highest temperature
measured at any one of the specified hotspot checkpoints.
See Figure 46: Hotspot temperature check points.
Note 2
The control pin is referenced to Vin-.
Note 3
The CXE15 is supplied as standard with active high logic.
Control input pulled low: Unit disabled.
Control input left open: Unit enabled.
Figure 46: Hot Spot Location on all Models
Note 4
Thermal reference set up: Unit mounted on an edge card test
board 215mm x 115mm. Test board mounted vertically. For test
details and recommended set-up see Application Note 116.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is accessible only to trained personnel. The user
must provide the recommended fusing in order to comply with
safety approvals.
23
www.artesyn.com
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
NORTH AMERICA
e-mail: [email protected]
☎ 800 769 7274
☎+ 508 628 5600
EUROPEAN LOCATIONS
e-mail: [email protected]
IRELAND
☎+ 353 24 93130
AUSTRIA
☎+ 43 1 80150
FAR EAST LOCATIONS
e-mail: [email protected]
HONG KONG
☎+ 852 2699 2868
LFDS_CXE15_20021001.PDF
Long Form Data Sheet  Artesyn Technologies® 2001
The information and specifications contained in this data sheet are
believed to be correct at time of publication. However, Artesyn
Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to
change without notice. No rights under any patent accompany the
sale of any such product(s) or information contained herein.
24
www.artesyn.com