48V 400-600 Amp Breaker Panel (BIP) ASIA EUROPE AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AP6C64AA A breaker interface panel, also knows as a power distribution unit (PDU), or frame supervisory panel (FSP), improves system power stability and provides a convenient centralized location for all customer load circuit breakers, alarms, and filtering. Electrical Specs INPUT DC input -40 VDC to –75 VDC Transients ANSI T1.315-1994, FTZ19, BTR2511 Input feeds 4 x 100A each 4 x 150A each (available in the future) OUTPUT DC output 20 x 25A breakers total Four breaker modules, each with 5 x 25A breakers Alarm signals Critical, major, minor alarms Special Features • Low profile: • Fits in 2U height, • 3.47", 88.1 mm • 23" width • 4 x 100 A input feeds, upgradeable to 4 x 150A input feeds • supports A & B redundant input feeds • 4 hot swappable Breaker Modules + one Alarm Module • Breaker Modules available in various configurations, all come equipped with: • 28,200 µF capacitor bank • automatic inrush current limiting • hot swappable, field replaceable without service interruption • Breaker Module configurations: • 5A 5A 5A 5A 5A • 20A 20A 20A 20A 20A • 25A 25A 5A 25A 25A • 10A 5A 30A 5A 10A • 25A 25A 25A 25A 25A • 30A 30A 5A 30A 30A • other configurations available on request, please consult your Astec representative • Standard Alarm module comes equipped with: • isolated alarm contacts • input feed fail alarm • output breaker trip alarm • critical, major, minor alarms • end aisle lamp drive • fully programmable, 6 bit, shelf ID • LED test switch • connections for voice and data jacks • Enhanced, customized alarm modules available by special order 182 America’s (USA): 1-888-41-ASTEC Environmental EMC/EMI: No switching components, inherently EMI/EMC benign ESD: Bellcore GR-1089-CORE, ETSI 300 386-1, (15kV) Operating Temperature and Humidity -5°C to +55°C normal, 5% to 85% RH, non-condensing -8°C to +65°C short term Shock and Vibration: Fire Resistance: Bellcore GR-063-CORE and ETSI 300 019 Zone 4 earthquake UL94V-0 Safety UL CSA EN Bellcore Europe (UK): 44 (1384) 842-211 1950 C22.2 950 60850, 41003 GR-063-CORE Asia (HK): 852-2437-9662 rev 12.01.01