ASTEC HPS3KW-NNR-032

3000 Watts
Total Power:
Input Voltage:
# of Outputs:
3000 Watts
180-264 VAC
Single
HPS3KW
Electrical Specs - *Module only
Input
Special Features - *Module only
•
•
•
•
•
•
•
•
•
•
•
•
•
Input Range
Frequency
Inrush Current
Efficiency
EMI Filter
Power Factor
Leakage Current
180-264VAC
47 - 63 Hz
100A (peak)
85% typical at full load
CISPR22 Class A
0.98 typical
1.16 mA @ 240 VAC
Output
Active Power Factor Correction
EN61000-3-2 Harmonic Compliance
Remote INHIBIT
Single Wire Parallel
Built-in EMI Filter
Low Output Ripple
+5V standby Output
Built-in Cooling Fans
Over Current Protection
Over Voltage Protection
Over Temperature Protection
Hot Swap
Built-in OR'ing Diodes
DC Voltage
Adjustment Range
Supervisory Output
Hold Up Time
Over Current
Over Voltage
51.4V @ 57A*
5Vsb @ 5A
± 5%
5V @ 5A
20ms
51.4V: 110% - 150%
5Vsb: 101% - 125%
60V Max
Logic Control
ENABLE
Requires contact closure from
"PSON" to 5Vsb return.
TTL signal LOW
TTL signal LOW;
goes HIGH inthe event of failure
TTL logic signal goes high 1001000 msec after 48VDC output. It
goes LOW at least 1ms before loss
of regulation.
AC OK
POWER FAIL
POWER GOOD
Environmental - *Module only
*10% Minimum load required.
Operating Temperature: +5°C to 40°C
Non-Operating Temperature: -40° to +70°C
Electromagnetic Susceptibility: Designed to meet
EN61000-4-2, -4-3, 4-4, -4-5 Level 3
Humidity: 5 to 95% RH, non-condensing
Operating: Sinusoidal Vibration - 0.25G zero to peak,
10 to 500Hz, 0.25 oct/min in each three mutually
perpendicular axes. Random vibration - 0.002 G2/Hz,
10 to 500Hz, nominal 1G rms.
Safety - *Module only
UL 60950 (UL Recognized)
NEMKO EN60950
TUV EN60950
CE Mark
Non-operating: Sinusoidal Vibration - 0.75G zero to
peak, 10 to 500Hz, 0.50 oct/min in each three mutually
perpendicular axes. Random vibration - 0.008 G2/Hz,
10 to 500Hz, nominal 2G rms.
MTBF (demonstrated): >500KHrs at full load, 40°C
1
Americas: 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
rev 08.29.05
HPS3KW Module
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
DC Output Connector Pinout Assignment
Signal Pins
Current Monitor
N = None
D
C
B
A
Redundancy
Power
R = OR’ing diode
3K = 3000 W
HPS 3 K W N N R
Output Voltage
Auxiliary Fan
Voltage
1
5Vsb
5Vsb
5Vsb
48LS
2
5Vsb rtn
5Vsb rtn
5Vsb rtn
AC OK
3
PSON
PRESENT
PSKI LL
PWOK
5
A0
A1
A2
Reserved
Power Blades
P1, P2
P3, P4
48VDC RETURN
48VDC
0 3 2
Standard Options
2
W = 48 V
4
SCL
SCL/SDA RTN
SDA
FAIL
032 = I C Interface
p1
p2
P3
P4
N = None
DC OUTPUT CONNECTOR: FCI 51874-001
DC OUTPUT MATING CONNECTOR: FCI 51875-001
Mechanical Drawings
AC INPUT CONNECTOR: FCI 51870-001
AC MATING CONNECTOR: FCI 51871-001
(REQUIRES 2 FCI 51869-001 BACKSHELL)
Neutral
Earth
Line
(78.00)
(27.50)
(81.00)
(118.00)
(16.00)
550.2±0.5
(21.66")
(19.3)
8.60±0.25
(47.2)
32.0±1(2x)
(16.8)
+0.25
-0.37
(24.7)
(19.1)
123.50±0.4
(4.86")
(7.80)
89.74±0.37
117.7±0.4
(2x)64.00±0.25
69.50±0.4
(2.74")
www.astecpower.com
2
HPS3KW Rack
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering
Information
Rack Chassis
•
•
•
•
Hot Swap
Can accommodate up to 18KW of bulk power
Easy AC input connect
Easy DC output connect
26.25"
3
INPUT
5.25"
TOP VIEW
Americas: 1-888-41-ASTEC
Node Interface
Module
17.00"
Output
PCB
BACK
VIEW
60 pin card edge
connector
Node Access Port
SIDE VIEW
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
3