ASTEC LPS110

110 Watts
LPS110 Series
Total Power: 80-110 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
Electrical Specs
Input
Input range
Special Features
•
•
•
•
•
•
•
•
•
•
•
Universal input
High efficiency
Remote sense
Built-in EMI filter
Low output ripple
Adjustable output
Power fail
Overvoltage protection
Overload protection
Optional L bracket (-B suffix)
Cover kit available LPX110-C
Environmental
Frequency
47-440 Hz
Inrush current
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
Input current
2.5 A max. (RMS) @ 115 VAC
Efficiency
70% typical at full load
EMI filter
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Safety ground
leakage current
<0.5 mA @ 50/60 Hz, 264 VAC-input
Output
Maximum power
80 W for convection;
110 W with 30 CFM forced air
Adjustment range
±5% minimum
Hold-up time
20 ms @80 W load, 115 VAC nominal
line
Overload protection
Short circuit protection. Case overload
protected @ 110-145% above peak
rating
Overvoltage protection
5 V output: 5.7-6.7 VDC. Other outputs
10% to 20% above nominal output.
Latching type, recycle AC to reset.
Logic Control
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Power failure
TTL logic signal goes high 50-150 msec
after main output. It goes low at least 4
msec before loss of regulation.
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Remote sense
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
100
85-264 VAC
120-300 VDC
Safety
VDE
UL
CSA
NEMKO
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1245 (LC #84997)
E132002
LR53982C
P95100376
1563, 1564, 1565, 1566, 1567
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 12.10.03
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
LPS110 Series
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LPS113
LPS114
LPS115
LPS118
12 V
15 V
24 V
48 V
0A
0A
0A
0A
6.7 A
5.3 A
3.3 A
1.7 A
9.2 A
7.3 A
4.6 A
2.3 A
10.4 A
8.3 A
5.2 A
2.6 A
±2%
±2%
±2%
±2%
120 mV
150 mV
240 mV
480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load.
Note: -B suffix added to model number indicates L bracket option.
-B Bracket
Pin Assignments
LPS114
LPS115
LPS118
SK1-1
SK1-3
SK1-5
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK2-7
SK2-8
SK2-9
SK201-1
SK201-2
SK202-1
SK202-2
+12 V
+12 V
+12 V
Common
Common
Common
Common
+12 V
+12 V
+sense
-sense
Pok
GND
+15 V
+15 V
+15 V
Common
Common
Common
Common
+15 V
+15 V
+sense
-sense
Pok
GND
+24 V
+24 V
+24 V
Common
Common
Common
Common
+24 V
+24 V
+sense
-sense
Pok
GND
+48 V
+48 V
+48 V
Common
Common
Common
Common
+48 V
+48 V
+sense
-sense
Pok
GND
2.5"
(63.5)
6.4"
(162.6)
0.86"
(21.8)
5.9"
(150.0)
0.25"
(6.35)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L Bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Warranty: 1 year
8. Weight: 1.25 lb / 0.57 kg
M2
4.0"
(101.6)
VOLTAGE ADJ
Molex 09-50-8091 (USA)
09-91-0900 (UK)
PINS: 08-58-0111
Remote sense/power fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
Astec Connector Kit #70-841-007, includes all of the above
7.3"
(185.5)
2.2"
(56)
Mating Connectors
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC Outputs:
#6-32 PEM
6 places
4.28"
(108.6)
3.5"
(88.9)
1
2
3
4
5
6
7
8
9
1
3
SK 1
6.5"
(165.1)
0.25"
(6.35)
7.0"
(177.8)
SK 201
(+S) 1
(-S) 2
SK 202
(POK)
1 2
SK 2
ConnectorLPS113
GND
N
L
M1
0.156" (4)
DIA (4 places)
1.80"
(45.7)
0.12"
(3)
www.astecpower.com
101