110 Watts LPS110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Special Features • • • • • • • • • • • Universal input High efficiency Remote sense Built-in EMI filter Low output ripple Adjustable output Power fail Overvoltage protection Overload protection Optional L bracket (-B suffix) Cover kit available LPX110-C Environmental Frequency 47-440 Hz Inrush current <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C Input current 2.5 A max. (RMS) @ 115 VAC Efficiency 70% typical at full load EMI filter FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 VAC-input Output Maximum power 80 W for convection; 110 W with 30 CFM forced air Adjustment range ±5% minimum Hold-up time 20 ms @80 W load, 115 VAC nominal line Overload protection Short circuit protection. Case overload protected @ 110-145% above peak rating Overvoltage protection 5 V output: 5.7-6.7 VDC. Other outputs 10% to 20% above nominal output. Latching type, recycle AC to reset. Logic Control Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Power failure TTL logic signal goes high 50-150 msec after main output. It goes low at least 4 msec before loss of regulation. Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions 100 85-264 VAC 120-300 VDC Safety VDE UL CSA NEMKO CB CE 0805/EN60950 (IEC950) UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 Certificate and report Mark (LVD) 11774-3336-1245 (LC #84997) E132002 LR53982C P95100376 1563, 1564, 1565, 1566, 1567 Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 rev 12.10.03 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 LPS110 Series Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 Ripple P/P (PARD)3 LPS113 LPS114 LPS115 LPS118 12 V 15 V 24 V 48 V 0A 0A 0A 0A 6.7 A 5.3 A 3.3 A 1.7 A 9.2 A 7.3 A 4.6 A 2.3 A 10.4 A 8.3 A 5.2 A 2.6 A ±2% ±2% ±2% ±2% 120 mV 150 mV 240 mV 480 mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load. Note: -B suffix added to model number indicates L bracket option. -B Bracket Pin Assignments LPS114 LPS115 LPS118 SK1-1 SK1-3 SK1-5 GND Neutral Line GND Neutral Line GND Neutral Line GND Neutral Line SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK2-7 SK2-8 SK2-9 SK201-1 SK201-2 SK202-1 SK202-2 +12 V +12 V +12 V Common Common Common Common +12 V +12 V +sense -sense Pok GND +15 V +15 V +15 V Common Common Common Common +15 V +15 V +sense -sense Pok GND +24 V +24 V +24 V Common Common Common Common +24 V +24 V +sense -sense Pok GND +48 V +48 V +48 V Common Common Common Common +48 V +48 V +sense -sense Pok GND 2.5" (63.5) 6.4" (162.6) 0.86" (21.8) 5.9" (150.0) 0.25" (6.35) Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting holes M1 and M2 should be grounded for EMI purposes. 5. Mounting hole M1 is safety ground connection. 6. L Bracket mounting (6-32) maximum insertion depth is .20” (5). 7. Warranty: 1 year 8. Weight: 1.25 lb / 0.57 kg M2 4.0" (101.6) VOLTAGE ADJ Molex 09-50-8091 (USA) 09-91-0900 (UK) PINS: 08-58-0111 Remote sense/power fail: Molex 22-01-1022 (USA) 22-01-1023 (UK) PINS: 08-50-0114 Astec Connector Kit #70-841-007, includes all of the above 7.3" (185.5) 2.2" (56) Mating Connectors AC Input: Molex 09-50-8051 (USA) 09-91-0500 (UK) PINS: 08-58-0111 DC Outputs: #6-32 PEM 6 places 4.28" (108.6) 3.5" (88.9) 1 2 3 4 5 6 7 8 9 1 3 SK 1 6.5" (165.1) 0.25" (6.35) 7.0" (177.8) SK 201 (+S) 1 (-S) 2 SK 202 (POK) 1 2 SK 2 ConnectorLPS113 GND N L M1 0.156" (4) DIA (4 places) 1.80" (45.7) 0.12" (3) www.astecpower.com 101