145 Watts LPQ142 Series Total Power: 110-145 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current Special Features • Active power factor correction • IEC EN61000-3-2 compliance • Adjustable outputs on 1, 3 & 4 Remote sense on main output • Single wire current sharing • Power fail and remote inhibit • Built-in EMI filter • Low output ripple • Overvoltage protection • Overload protection • Thermal overload protection • Adjustable floating 4th output • Optional cover (-C suffix) • Optional fan cover (-CF suffix) Environmental Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 85-264 VAC, 120-300 VDC 47-63 Hz 38 A max, cold start @ 25°C 75% typical at full load Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted 0.99 typical 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power Adjustment range Hold-up time Overload protection Overvoltage protection 80 W convection (60 W with cover-C) 145 W with 30 CFM forced air (100 W with cover-C) 3.3 - 5.5V on main; -12 - 15V on 3rd output 3.3 - 25 V on 4th output 20 ms @145 W load at nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Tracks outputs 1, 3 & 4; 10 to 35% Logic Control AC Power failure Remote inhibit Remote sense DC-OK 50° to 70°C TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation TTL High disables output. Contact closure causes outputs to "bounce" Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation Electromagnetic susceptibility: designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3 Humidity: Operating; non-condensing Safety 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ± .04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions 110 VDE UL CB CSA CE NEMKO 60950 60950 Certificate and report 60950 Mark (LVD) EN 60950/EMKO-TUE Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 rev 08.24.04 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 LPQ142 Series Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load Regulation2 Ripple P/P(PARD)3 LPQ142 5 V (3.3 - 5.5 V) 12 V -12 V (-12 -15 V) ±3.3-25 V 0A 0A 0A 0.5 A 12 A 5A 1A 1.5 A 25 A 6A 1.5 A 4.5 A 27 A 9A 2A 5A ±2% ±3% ±3% ±3% 50 mV 120 mV <1% <50mV or 1% 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. 4th output adjustable 3.3-25 V factory set at 5 V. 5. *Minimum loads are required when output set below 5 Volts 6. Remote inhibit resets OVP latch Note: -C suffix added to the model number indicates cover option. -CF suffix added to the model number indicates fan cover option. Pin Assignments Connector LPQ142 SK1 PIN 1 PIN 3 PIN 5 GROUND NEUTRAL LINE SK2 PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 +12 V COMMON -12 V COMMON +5 V to +25 V (Float) COMMON (Float) TB-1 TB-2 COMMON +5 V SK4 MAIN OUTPUT 6 V4V4+ COMM -12V OUT COMM +12V OUT SK2 L 1 N 5 GND PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 Mating Connectors (SK1) AC Input: N/C DC OK N/C V1 SWP Common +V1 sense Sense common + inhibit - inhibit Power fail 6 1 SK6 -CF option M3 #6-32 (3X) 19.1 29.1 SK6 10 SK1 1.5 (38.1) M3 (2X) 6.4 161.5 171.5 #6-32 4.00 (101.6) (4X) 63.5 Molex 09-50-8051 (USA) Molex 09-91-0500 (UK) PINS: 08-58-0111 (SK2) Aux DC Output: Molex 09-50-8061 (USA) Molex 09-91-0600 (UK) PINS: 08-58-0111 (SK6) Control Signals: Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 (SK4) Main output: Molex BB-124-08 Astec connector kit #70-841-017, includes al of the above. (2X) 119.6 (2X) 139.7 7.0 (177.8) M3 (8 places) #6-32 (8 places) Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02”. 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is 0.12”. 5. Warranty: 1 year 6. Weight: 1.63 lb / 0.74 kg www.astecpower.com 111