R E L 11 0 11 0 Wa t t O p e n F rame Switching Power Supply with PFC series 110 Watts Output Power Universal 85-265VAC Input 1, 2, 3, and 4 Outputs Active Power Factor Correction 2.5VDC to 48VDC Outputs 5” x 3” x 1.32” Model Number Output #1 Output #2 Output #3 Output #4 Medical Versions Available Contact Factory SINGLE OUTPUT REL110-1001 REL110-1002 REL110-1003 REL110-1004 REL110-1005 REL110-1006 REL110-1007 REL110-1008 2.5V/22A 3.3V/22A 5V/22A 12V/9.2A 15V/7.3A 24V/4.6A 28V/3.9A 48V/2.3A DUAL OUTPUT REL110-2001 REL110-2002 REL110-2003 REL110-2004 REL110-2005 3.3V/10A 5V/10A 5V/10A 12V/5A 15V/4A 5V/5.6A 12V/5A 24V/3A -12V4A -15V/3A TRIPLE OUTPUT REL110-3001 REL110-3002 5V/10A 5V/10A 12V/3A 15V/2A QUAD OUTPUT REL110-4001 REL110-4002 REL110-4003 REL110-4004 REL110-4005 REL110-4006 REL110-4007 3.3V/10A 5V/10A 5V/10A 5V/10A 5V/10A 5V/10A 5V/10A 5V/6A 3.3V/6A 3.3V/6A -5V/6A -5V/6A 24V/2A 24V/2A -12V/3A -15V/2A 12V/2A 12V/2A 15V/2A 12V/2A 15V/2A 12V/2A 15V/2A Order On-Line! WWW.ASTRODYNE.COM astrodyne.com -12V/2A -12V/2A -15V/2A -12V/2A -15V/2A -12V/2A -15V/2A 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 R E L 11 0 11 0 Wa t t O p e n F rame Switching Power Supply with PFC INPUT SPECIFICATIONS Input Voltage, Full Range: Active PFC Input Frequency Inrush Current Leakage Current ENVIRONMENTAL SPECIFICATIONS 85-264 VAC >0.95@115VAC 47-63Hz. 30A @ 115VAC, typ 4 40A @ 230VAC, typ 4 <300uA @ 240VAC OUTPUT SPECIFICATIONS Output Power Minimum Load Requirement Max Current (A, Peak) Initial Accuracy Voltage Adjust Load Regulation Cross Regulation Line Regulation Temperature Coefficient Ripple/Noise Overvoltage Protection Remote Sense (Singles Only) Hold Up/Start Up Times Short Circuit Protection Current Limit Safety EMC 0 to +60 °C 4 10-95%, Description 4 -40 to +85 °C 4 100KHrs MIL-Std 217F To MIL-Std 810E Oper. Temperature Relative Humidity Storage Temperature MTBF Shock & Vibration PHYSICAL SPECIFICATIONS 80W, Conv/110W Forced Air 10% See Model Selection Chart 7 +/-1%, typ ± 5%, typ ± 1%, typ +/-5% ± 0.5%, typ ± 0.02%/°C 100mV Pk-Pk, typ 110-150%, Type 2 & 3 250mV compensation 16mS/4Sec, typ Continuous 4 110-160% typ, Auto Recovery GENERAL SPECIFICATIONS Input-Output Isolation Output-Ground Isolation Input-Ground Isolation Efficiency (@ Full Load) series Dimensions Material Flammability Construction Weight 5”x3”x1.32” to UL94V-0 Open Frame 0.8lb SPECIFICATION NOTES 1) All specifications typical @ 25°C, Nominal Line & Load, unless otherwise noted. 2) O/P noise measured directly at pins/terminals with 0.1uFbypass, pk-pk @ 20MHz bandwidth. 3) Ripple and Noise dependant upon output voltage as specified per particular model. 4) These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed or implied. 5) Isolation for up to 1 minute duration. 6) No termination necessary with control pin to maintain constant “ON” operation (if applicable to this model) 7) Max load (peak) specified for 10mS max, 20% duty cycle, minimum load on all outputs 3000VAC 5 500VAC 1500VAC 82%, typ (or See Chart/Curve) UL60950/EN60950 Approved EN55022/B, EN61000-3-2,3/A EN61000--4-2,3,4,5,6,8,11/Cr A All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted A Blue Number means see respective Specification WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 R E L 11 0 11 0 Wa t t O p e n F rame Switching Power Supply with PFC MECHANICAL DIMENSIONS series RECOMMENDED AIR FLOW DIRECTION 1 – Optimum OPEN FRAME 2 – Good 3 – Good 4 - Fair 3 1 P2 4 AC INPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT 1 1 1 1 1 1 1 1 THERMAL PERFORMANCE V1 ADJUST L 1 P1 P3 1 (+) OUTPUT 1 2 (+) SENSE 3 (-) SENSE 4 (-) OUTPUT 1 5 (-) P.F. RTN 6 (+) P.F. SIG N GND P3 1 SINGLE OUTPUT MODEL 110 4.70 (119.4) P2 1 (-) 2 (+) 3 (-) 4 (+) 5 (-) 6 (+) 7 (-) 8 (-) 9 (+) 10 (+) 1 2.70 (68.6) P2 3.00 (76.2) AC INPUT L N OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT 4 4 3 3 2 2 1 1 1 1 1 P3 GND P3 1 (-) 2 (+) 80 CONVECTION COOLING 70 60 50 CONVECTION COOLING WITH CHASIS / COVER 40 30 20 10 V1 ADJUST P1 FORCED AIR COOLING 90 5.00 (127.0) .15 (3.8) Maximum Output Power vs. Ambient Temperature 100 .128 DIA MOUNTING HOLE (4 PLACES) Output Power (Watts) 2 P2 1 (-) 2 (-) 3 (-) 4 (-) 5 (+) 6 (+) 7 (+) 8 (+) 0 P.F. RTN P.F. SIG 0 10 20 30 40 50 60 70 Ambient Temperature, (C) MULTIPLE OUTPUT MODEL .91 (23.1) 3.21 (81.5) 1.32(33.5) Max. 1.10 (27.9) CONNECTOR SPECIFICATIONS .75 (19.1) P1 AC Input OPTIONAL CHASSIS/COVER .156 friction lock header mates with Molex 09-50-3031 crimp terminal housing with Molex 2478 crimp terminal 4.70 (119.4) P2 DC Output (Single) .68 (17.2) .156 friction lock header mates with Molex 09-50-3081 crimp terminal 4-40 MOUNTING HOLES (4 PLACES) 1.48 (37.6) housing with Molex 2478 crimp terminal P2 DC Output (Multiple) .156 friction lock header mates with Molex 09-50-3101 crimp terminal 5.26 (133.6) housing with Molex 2478 crimp terminal 4.70 (119.4) 3 G Ground .187 quick disconnect terminal 3.12 (79.2) P3 P.F Sense (Single) P2 4 2 2.70 (68.6) AC INPUT .100 breakaway header mates with Molex 50-57-9002 crimp terminal housing with Molex 71851crimp terminal L P1 N P3 GND 1 ALL DIMENSIONS IN INCHES (MM) WWW.ASTRODYNE.COM 4-40 MOUNTING HOLE (4 PLACES) P3 Power Fail (Multiple) .100 breakaway header mates with Molex 50-57-9002 crimp terminal housing with Molex 71851 crimp terminal 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181