REL150 1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC series 150 Watts Output Power Universal 85-265VAC Input 1, 2, 3, and 4 Outputs Active Power Factor Correction 2.5VDC to 48VDC Outputs 6” x 3.83” x 1.32” Model Number Output #1 Output #2 Output #3 Output #4 Medical Versions Available Contact Factory SINGLE OUTPUT REL150-1001 REL150-1002 REL150-1003 REL150-1004 REL150-1005 REL150-1006 REL150-1007 REL150-1008 2.5V/30A 3.3V/30A 5V/30A 12V/12.5A 15V/10A 24V/6.3A 28V/5.4A 48V/3.1A DUAL OUTPUT REL150-2001 REL150-2002 REL150-2003 REL150-2004 REL150-2005 3.3V/15A 5V/15A 5V/15A 12V/7.5A 15V/5A 5V/8A 12V/5A 24V/3A -12V5A -15V/5A TRIPLE OUTPUT REL150-3001 REL150-3002 5V/15A 5V/15A 12V/4A 15V/3A QUAD OUTPUT REL150-4001 REL150-4002 REL150-4003 REL150-4004 REL150-4005 REL150-4006 REL150-4007 3.3V/15A 5V/15A 5V/15A 5V/15A 5V/15A 5V/15A 5V/15A 5V/8A 3.3V/8A 3.3V/8A -5V/8A -5V/8A 24V/3A 24V/3A -12V/3A -15V/2A 12V/2A 12V/2A 15V/2A 12V/2A 15V/2A 12V/2A 15V/2A Order On-Line! WWW.ASTRODYNE.COM astrodyne.com -12V/2A -12V/2A -15V/2A -12V/2A -15V/2A -12V/2A -15V/2A 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 REL150 1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC INPUT SPECIFICATIONS Input Voltage, Full Range: Active PFC Input Frequency Inrush Current Leakage Current ENVIRONMENTAL SPECIFICATIONS 85-264 VAC >0.95@115VAC 47-63Hz. 30A @ 115VAC, typ 4 40A @ 230VAC, typ 4 <300uA @ 240VAC OUTPUT SPECIFICATIONS Output Power Minimum Load Requirement Max Current (A, Peak) Initial Accuracy Voltage Adjust Load Regulation Cross Regulation Line Regulation Temperature Coefficient Ripple/Noise Overvoltage Protection Remote Sense (Singles Only) Hold Up/Start Up Times Short Circuit Protection Current Limit Safety EMC 0 to +60 °C 4 10-95%, Description 4 -40 to +85 °C 4 100KHrs MIL-Std 217F To MIL-Std 810E Oper. Temperature Relative Humidity Storage Temperature MTBF Shock & Vibration PHYSICAL SPECIFICATIONS 100W, Conv/150W Forced Air 10% See Model Selection Chart 7 +/-1%, typ ± 5%, typ ± 1%, typ +/-5% ± 0.5%, typ ± 0.02%/°C 100mV Pk-Pk, typ 110-150%, Type 2 & 3 250mV compensation 16mS/5Sec, typ Continuous 4 110-160% typ, Auto Recovery GENERAL SPECIFICATIONS Input-Output Isolation Output-Ground Isolation Input-Ground Isolation Efficiency (@ Full Load) series Dimensions Material Flammability Construction Weight 6”x3.83”x1.32” to UL94V-0 Open Frame 1.15lb SPECIFICATION NOTES 1) All specifications typical @ 25°C, Nominal Line & Load, unless otherwise noted. 2) O/P noise measured directly at pins/terminals with 0.1uFbypass, pk-pk @ 20MHz bandwidth. 3) Ripple and Noise dependant upon output voltage as specified per particular model. 4) These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed or implied. 5) Isolation for up to 1 minute duration. 6) No termination necessary with control pin to maintain constant “ON” operation (if applicable to this model) 7) Max load (peak) specified for 10mS max, 20% duty cycle, minimum load on all outputs 3000VAC 5 500VAC 1500VAC 82%, typ (or See Chart/Curve) UL60950/EN60950 Approved EN55022/B, EN61000-3-2,3/A EN61000--4-2,3,4,5,6,8,11/Cr A All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted A Blue Number means see respective Specification WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 REL150 1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC MECHANICAL DIMENSIONS series RECOMMENDED AIR FLOW DIRECTION OPEN FRAME 1 – Optimum 2 – Good 3 – Good 4 - Fair 3 P2 - P2 + AC INPUT 4 P3 1 (+) 2 (+) 3 (-) 4 (-) 5 (-) 6 (+) 7 (+) 8 (-) P1 N GND P3 SINGLE OUTPUT MODEL OUTPUT 1 1 OUTPUT 1 SENSE SENSE OUTPUT 1 P.F. RTN P.F. SIG REMOTE REMOTE .128 DIA MTG HOLE 4 PLACES 6.00 (152.4) .15 (3.8) 5.70 (144.8) P4 1 P4 1 (+) 2 (-) 1 3.53 (89.7) P2 3.83 (97.3) AC INPUT THERMAL PERFORMANCE V1 ADJUST 1 L OUTPUT 1 P2+ (+) REMOTE REMOTE RETURN P2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 (-) (+) (-) (+) (-) (-) (+) (+) (-) (-) (-) (+) (+) (+) OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT P3 1 2 3 4 5 6 (+) (+) (-) (-) (-) (+) OUTPUT 1 SENSE OUTPUT 1 SENSE P.F. RTN P.F. SIG 4 4 3 3 2 2 2 2 1 1 1 1 1 1 Output Power (Watts) 2 P2(-) 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 �O�CE� �O�CE� AI� AI� COOLING COOLING CONVECTION COOLING CONVECTION COOLING WITH CHASIS / COVE� 0 10 P1 N P3 GND MULTIPLE OUTPUT MODEL .70 (17.8) V1 ADJUST 20 30 40 50 60 70 Ambient Temperature, (C) L CONNECTOR SPECIFICATIONS 4.34 (110.2) 1.32 (33.5) Max 1.13 (28.7) .75 (19.1) P1 AC Input .156 friction lock header mates with Molex 09-50-3031 crimp terminal housing with Molex 2478 crimp terminal P2 DC Output (Single) OPTIONAL CHASSIS/COVER 6-32 screw down terminal accepts #6 ring tongue terminal P2 DC Output (Multiple) 5.70 (144.8) .156 friction lock header mates with Molex 09-50-3141 crimp terminal 4-40 MOUNTING HOLE (2 PLACES) .68 (17.2) housing with Molex 2478 crimp terminal 1.48 (37.6) G Ground .187 quick disconnect terminal 6.25 (158.8) P3 Remote PF Sense 5.70 (144.8) 3 .100 breakaway header mates with Molex 50-57-9008 crimp terminal P4 housing with Molex 71851 crimp terminal 1 P3 P.F Sense (Multiple 3.96 (100.5) P2 .100 breakaway header mates with Molex 22-55-2061 crimp terminal 4 2 housing with Molex 70058 crimp terminal 3.53 (89.7) AC INPUT P3 L P1 4-40 MOUNTING HOLE (4 PLACES) N GND ALL DIMENSIONS IN INCHES (MM) 1 WWW.ASTRODYNE.COM P4 Remote l (Multiple) .100 breakaway header mates with Molex 50-57-9002 crimp terminal housing with Molex 71851 crimp terminal 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181