rel150 series

rel150
1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC
series
150 Watts Output Power
Universal 85-265VAC Input
1, 2, 3, and 4 Outputs
Active Power Factor Correction
2.5VDC to 48VDC Outputs
6” x 3.83” x 1.32”
Model Number
Output #1
Output #2
Output #3
Output #4
Medical Versions Available
Contact Factory
SINGLE OUTPUT
REL150-1001
REL150-1002
REL150-1003
REL150-1004
REL150-1005
REL150-1006
REL150-1007
REL150-1008
2.5V/30A
3.3V/30A
5V/30A
12V/12.5A
15V/10A
24V/6.3A
28V/5.4A
48V/3.1A
DUAL OUTPUT
REL150-2001
REL150-2002
REL150-2003
REL150-2004
REL150-2005
3.3V/15A
5V/15A
5V/15A
12V/7.5A
15V/5A
5V/8A
12V/5A
24V/3A
-12V5A
-15V/5A
TRIPLE OUTPUT
REL150-3001
REL150-3002
5V/15A
5V/15A
12V/4A
15V/3A
-12V/3A
-15V/2A
QUAD OUTPUT
REL150-4001
REL150-4002
REL150-4003
REL150-4004
REL150-4005
REL150-4006
REL150-4007
3.3V/15A
5V/15A
5V/15A
5V/15A
5V/15A
5V/15A
5V/15A
5V/8A
3.3V/8A
3.3V/8A
-5V/8A
-5V/8A
24V/3A
24V/3A
-12V/2A
-12V/2A
-15V/2A
-12V/2A
-15V/2A
-12V/2A
-15V/2A
WWW.ASTRODYNE.COM
12V/2A
12V/2A
15V/2A
12V/2A
15V/2A
12V/2A
15V/2A
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC
INPUT SPECIFICATIONS
Input Voltage, Full Range:
Active PFC
Input Frequency
Inrush Current
Leakage Current
85-264 VAC
>0.95@115VAC
47-63Hz.
30A @ 115VAC, typ 4
40A @ 230VAC, typ 4
<300uA @ 240VAC 0 to +60 °C 4
10-95%, Description 4
-40 to +85 °C 4
100KHrs
MIL-Std 217F
To MIL-Std 810E
Oper. Temperature
Relative Humidity
Storage Temperature
MTBF
Shock & Vibration
PHYSICAL SPECIFICATIONS
100W, Conv/150W Forced Air
10%
See Model Selection Chart 7
+/-1%, typ
± 5%, typ
± 1%, typ
+/-5%
± 0.5%, typ
± 0.02%/°C
100mV Pk-Pk, typ 110-150%, Type 2 & 3
250mV compensation
16mS/5Sec, typ
Continuous 4
110-160% typ, Auto Recovery
GENERAL SPECIFICATIONS
Input-Output Isolation
Output-Ground Isolation
Input-Ground Isolation
Efficiency (@ Full Load)
Safety
EMC
series
ENVIRONMENTAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Output Power
Minimum Load Requirement
Max Current (A, Peak)
Initial Accuracy
Voltage Adjust
Load Regulation Cross Regulation
Line Regulation
Temperature Coefficient
Ripple/Noise
Overvoltage Protection
Remote Sense (Singles Only)
Hold Up/Start Up Times
Short Circuit Protection
Current Limit
rel150
Dimensions
Material Flammability
Construction
Weight
6”x3.83”x1.32”
to UL94V-0
Open Frame
1.15lb
SPECIFICATION NOTES
1) All specifications typical @ 25°C, Nominal Line & Load, unless otherwise
noted.
2) O/P noise measured directly at pins/terminals with 0.1uFbypass, pk-pk @
20MHz bandwidth.
3) Ripple and Noise dependant upon output voltage as specified per particular
model.
4) These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed or implied.
5) Isolation for up to 1 minute duration.
6) No termination necessary with control pin to maintain constant “ON” operation
(if applicable to this model)
7) Max load (peak) specified for 10mS max, 20% duty cycle, minimum load on
all outputs
3000VAC 5
500VAC
1500VAC
82%, typ (or See Chart/Curve)
UL60950/EN60950 Approved
EN55022/B, EN61000-3-2,3/A
EN61000--4-2,3,4,5,6,8,11/Cr A
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
A Blue Number means see respective Specification
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
rel150
1 5 0 Wa t t O p e n F rame Switching Power Supply with PFC
MECHANICAL DIMENSIONS
series
RECOMMENDED AIR FLOW DIRECTION
OPEN FRAME
1 – Optimum
2 – Good
3 – Good
4 - Fair
3
P2 -
P2 +
AC
INPUT
4
P3
1 (+)
2 (+)
3 (-)
4 (-)
5 (-)
6 (+)
7 (+)
8 (-)
P1
N
GND
P3
SINGLE OUTPUT MODEL
OUTPUT 1
1
OUTPUT 1
SENSE
SENSE
OUTPUT 1
P.F. RTN
P.F. SIG
REMOTE
REMOTE
.128 DIA
MTG HOLE
4 PLACES
6.00 (152.4)
.15 (3.8)
5.70 (144.8)
P4
1
P4
1 (+)
2 (-)
1
3.53 (89.7)
P2
3.83 (97.3)
AC
INPUT
THERMAL PERFORMANCE
V1 ADJUST
1
L
OUTPUT 1
P2+
(+)
REMOTE
REMOTE
RETURN
P2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
(-)
(+)
(-)
(+)
(-)
(-)
(+)
(+)
(-)
(-)
(-)
(+)
(+)
(+)
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
P3
1
2
3
4
5
6
(+)
(+)
(-)
(-)
(-)
(+)
OUTPUT 1
SENSE
OUTPUT 1
SENSE
P.F. RTN
P.F. SIG
4
4
3
3
2
2
2
2
1
1
1
1
1
1
Output Power (Watts)
2
P2(-)
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
O
O CE
CE AI
AI COOLING
COOLING
CONVECTION COOLING
CONVECTION COOLING
WITH CHASIS / COVE
0
10
P1
N
P3
GND
MULTIPLE OUTPUT MODEL
.70 (17.8)
V1 ADJUST
20
30
40
50
60
70
Ambient Temperature, (C)
L
CONNECTOR SPECIFICATIONS
4.34 (110.2)
1.32 (33.5) Max
1.13 (28.7)
.75 (19.1)
P1 AC Input
.156 friction lock header mates with Molex 09-50-3031 crimp terminal
housing with Molex 2478 crimp terminal
P2 DC Output (Single)
OPTIONAL CHASSIS/COVER
6-32 screw down terminal accepts #6 ring tongue terminal
P2 DC Output (Multiple)
5.70 (144.8)
4-40
MOUNTING HOLE
(2 PLACES)
.68 (17.2)
1.48 (37.6)
6.25 (158.8)
.156 friction lock header mates with Molex 09-50-3141 crimp terminal
housing with Molex 2478 crimp terminal
G
Ground
.187 quick disconnect terminal
P3 Remote PF Sense
5.70 (144.8)
3
P4
1
.100 breakaway header mates with Molex 50-57-9008 crimp terminal
housing with Molex 71851 crimp terminal
P3 P.F Sense (Multiple
3.96 (100.5)
P2
4
2
3.53 (89.7)
AC
INPUT
P3
L
P1
4-40
MOUNTING HOLE
(4 PLACES)
N
GND
ALL DIMENSIONS IN INCHES (MM)
1
WWW.ASTRODYNE.COM
.100 breakaway header mates with Molex 22-55-2061 crimp terminal
housing with Molex 70058 crimp terminal
P4 Remote l (Multiple)
.100 breakaway header mates with Molex 50-57-9002 crimp terminal
housing with Molex 71851 crimp terminal
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458