AUK S339P

S339P
Semiconductor
Quad Voltage Comparator
Description
The S339 consists of four independent voltage comparators designed to operate from
a single power supply over a wide voltage range.
Features
•
•
•
•
•
•
•
•
Single Supply Operation: 2V to 36V.
Dual Supply Operation: ±1V to ±18V.
Allow Comparison of Voltages Near Ground Potential.
Low Current Drain 800uA Typ.
Compatible with all Forms of Logic.
Low Input Bias Current: 25nA Typ.
Low Input Offset Current: ±5nA Typ.
Low Offset Voltage: ±1mV Typ.
Applications
• Transducer amplifier
• DC gain blocks
• Conventional operational amplifiers
Ordering Information
Type NO.
S339P
Marking
Package Code
S339P
DIP-14
Outline Dimensions
unit : mm
Block Diagram
A
KSI-L009-002
1
S339P
Absolute maximum ratings
Characteristic
Symbol
Ratings
Unit
Supply voltage
VCC
36 or ±18
V
Differential input voltage
VIND
36
V
Input voltage
VIN
-0.3 ~ +36
V
Power Dissipation
PD
570
mW
Operating temperature
Topr
-40 ~ +85
°C
Storage temperature
Tstg
-65 ~ 150
°C
Electrical Characteristics
(Unless otherwise specified. VCC = 5V and –40 °C ≤ Ta ≤ +85 °C)
Characteristic
Symbol
Test Condition
VO = 1.4V, Rs = 0Ω
Min. Typ.
Max.
Unit
-
±2
±5
mV
-
-
±5
±50
nA
IIB
-
-
25
250
nA
Input Common Mode
Voltage Range
VICR
-
0
-
VCC –1.5
V
Supply Current
ICC
VCC = 5V, RL = ∞, All Channel
-
0.8
2
mA
Large Signal Voltage Gain
AV
VCC = 15V , RL = 15 KΩ
-
200
-
V/mV
Output Voltage (‘L’ Level)
VSAT
VIN+= 0V, VIN-= 1V
ISINK≤ 4mA
-
130
400
mV
Response Time
tRES
VRC = 5V, RL = 5.1KΩ
-
1.3
-
uS
Output Sink Current
ISINK
VO≤1.5V,
VIN+ = 0V, VIN- = 1V
6
16
-
mA
Output Leakage Current
ILeak
VO = 5V
VIN+ = 1V, VIN- = 0V
-
0.1
-
nA
Input Offset Voltage
VIOS
Input Offset Current
IIOS
Input Bias Current
KSI-L009-002
2
S339P
Electrical Characteristic Curves
Fig. 1 VCC-ICC
Fig. 2 VCC-IIB
Fig. 3 VOL-ISINK
Fig. 4 PD-Ta
Fig. 5 VIN,VOUT-trsp
Fig. 6 VIN,VOUT-trsp
Ω
Ω
KSI-L009-002
3
S339P
These AUK Corp. products are intended for usage in general electronic equipment
(Office and communication equipment, measuring equipment, domestic
electrification, etc.) Please make sure that you consult with us before you use these
AUK products in equipm- ents which require high quality and/or reliability, and in
equipments which could have major impact to the welfare of human life(atomic energy
control, airplane, spaceship, traffic signal, combustion central, all types of safety
device, etc.) AUK cannot accept liability to any damage which may occur in case
these AUK products were used in the mentioned equipments without prior consultation
KSI-L009-002
4