AUK SHE124MD_1

Semiconductor
SHE124MD / SHE124MD-(B)
High Efficiency LED Lamp
Features
• Yellow-Green Colored lens type
• φ5mm(T-13/4) all plastic mold type
• Super luminosity
Application
• Massage Board
• Variable message signs(VMS)
Outline Dimensions
unit :
STRAIGHT TYPE
mm
STOPPER TYPE
5.0±0.2
5.0±0.2
8.6±0.2
8.6±0.2
0.8±0.2
0.8±0.2
3.5±0.5
0.5
0.5
25.0 MIN
25.0 MIN
1.0MIN
1.0MIN
2.54NOM
2.54NOM
1
2
5.8±0.2
1
2
5.8±0.2
PIN Connections
1. Anode
2. Cathode
KLE-3017-000
1
SHE124MD / SHE124MD-(B)
Absolute maximum ratings
Characteristic
Symbol
Ratings
Unit
Power Dissipation
PD
100
mW
Forward Current
IF
40
mA
IFP
65
mA
Reverse Voltage
VR
4
V
Operating Temperature
Topr
-20∼85
℃
Storage Temperature
Tstg
-30∼100
℃
1
* Peak Forward Current
2
260℃ for 5 seconds
* Soldering Temperature
Tsol
*1.Duty ratio = 1/16, Pulse width = 0.1ms
*2.Keep the distance more than 2.0mm from PCB to the bottom of LED package
Electrical Characteristics
Characteristic
Ta=25˚C
Symbol
Test Condition
Forward Voltage
VF
IF= 20mA
1.6
2.0
2.5
V
*4Luminous Intensity
IV
IF= 20mA
155
350
780
mcd
Peak Wavelength
λP
Δλ
IR
IF= 20mA
-
570
-
nm
IF= 20mA
-
30
-
nm
VR=4V
-
-
10
uA
IF= 20mA
-
±20
-
deg
Spectrum Bandwidth
Reverse Current
*3Half Angle
θ1/2
Min. Typ. Max.
Unit
*3. θ1/2 is the off-axis angle where the luminous intensity is 1/2 the peak intensity
*4. Luminous Intensity Maximum tolerance for each Grade Classification limit is ±18%
*4. Luminous Intensity classification
M
N
O
P
155~230
230~350
350~520
520~780
KLE-3017-000
2
SHE124MD / SHE124MD-(B)
Characteristic Diagrams
Fig. 1 IF - VF
Luminous Intensity Iv [mcd]
Forward Current IF [mA]
Fig. 2 IV - IF
Forward Voltage VF [V]
Forward
Current IF [mA]
Fig.4 Spectrum Distribution
Forward
Relative Intensity [%]
Current IF [mA]
Fig. 3 IF – Ta
Ambient Temperature Ta [℃]
Wavelength λ [nm]
Fig. 5 Radiation Diagram
Relative Luminous Intensity [%]
KLE-3017-000
3
SHE124MD / SHE124MD-(B)
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KLE-3017-000
4