AXTAL AXIS30

Issue: 08
Date: 2008-01-25
Specification
AXIS30
Oscillator type :
Wideband VCXO with low jitter
SMD replacement of Fujitsu M2 (F100)
Parameter
min.
max.
Unit
Frequency range
Standard frequencies
10
90
12.288 / 16.384 / 22.579 /
24.576 / 27.000 / 28.224
MHz
MHz
Frequency stability
Initial tolerance
vs. temperature in operating frequency
range -20°~+70°C (see Note 2)
vs. supply voltage variation
vs. load change
long term (aging) 1st year
Aging following years
Frequency adjustment range
Electronic Frequency Control (EFC)
range
*see Note 3
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Start-up time
Supply voltage VS
typ.
-10
-5
-10
-5
± 500
± 500
± 1000
± 1500
± 2000
± 2500
± 3000
0.25
0.15
Condition
± 80
ppm
ppm
ppm
10
5
10
5
ppm
ppm
ppm
ppm
@ 40°C
@ 40°C
ppm
ppm
ppm
ppm
ppm
ppm
ppm
V
V
Option 2 = “ ”
Option 2 = “500”
Option 2 = “1000”
Option 2 = “1500”*
Option 2 = “2000”*
Option 2 = “2500”*
Option 2 = “3000”*
Option 1 = “50“ (5 V)
Option 1 = “33” (3.3 V)
± 1100
± 1600
± 2100
± 2600
± 3200
4.75
3.15
positive
100
kΩ
HCMOS
15
Current consumption (steady state)
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
10
40
60
4
4.75
5.0
5.25
3.13
3.3
3.47
40
-45
+90
-50
+95
14.4x9.5x6 max
3
Tape & reel
1500
pF
ns
%
ms
V
V
mA
°C
°C
mm
gram
Option 1 = “50“ (5 V)
Option 1 = “33” (3.3 V)
@ +25°C
V
IEC 60286-3
HBM as in IEC 610004-2
@ VS/2
IEC 61837 CO 27
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Frequency vs. temperature response is a 2nd order parabola with turn-over point around +20°C to +30°C
3. *Pulling Range Option 2 = “1500” or larger only possible with EFC voltage 0.25V ~ 4.75 V
Ordering Code:
Model (Specification)
AXIS30
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option 1
Supply
50
Option 2
Pulling Range
500
AXIS30
page 1(2)
Frequency [MHz]
28.224
www.axtal.com
fon: +49 (6261)939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
VC
2
N.C.
3
GND
4
RF OUT
6
Vs
Function
Control Voltage (EFC)
No connection
Ground
RF Output (see table)
Supply Voltage
Environmental conditions:
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
Test conditions
4.3
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
2-20
2-58
4.6.3
2-27
4.6.8
Vibration, sinusoidal* 2-6
4.6.7
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Endurance tests
- ageing
- extended aging
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIS30
page 2(2)
www.axtal.com
fon: +49 (6261)939834
fax: +49 (6261) 939836
E-mail: [email protected]