Issue: 02 Specification AXE1000 Oscillator type : Crystal Oscillator (PXO) 1000 MHz Parameter min. Nominal frequency Frequency stability Initial tolerance vs. temperature in operating temperature range operating temperature range vs. supply voltage variation (pushing) vs. load change long term (aging) 1st year long term (aging) following years Frequency adjustment range Mechanical (internal trimmer) RF output Signal waveform Load Amplitude Harmonics Subharmonics (multiples of 100 MHz) at 500 MHz others Spurious Phase noise Date: 2008-01-25 typ. max. Unit Condition 1000 Note 2 -20 ±2 ±50 MHz ppm ppm ppm @25°C Steady state +70 ±1 ±1 ±2 ±1 °C ppm ppm ppm ppm/y VS ±5% VC ±5% @ +25°C per year @ +25°C ppm N.A. Sine wave 50 +7 -50 -25 -40 -80 -140 -135 -142 -140 -145 10 11.4 12 12.6 60 -40 +90 -55 +105 54 x 40 x 20 60 bulk 1500 Ω dBm dBc dBc dBc dBc dBc/Hz dBc/Hz dBc/Hz ms V mA °C °C mm gram ±10 % @ 10 kHz @ 100 kHz @ 1MHz Start-up time Supply voltage VS Current consumption (steady state @ +25°C) @25°C Operable temperature range Storage temperature range Enclosure (see drawing) (LxWxH) Weight Packing V HBM as in IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Other frequencies on request Ordering Code: Model (Specification) AXE1000 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Frequency [MHz] 1000.000 AXE1000 page 1(2) .axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin# Symbol Function 1 2 3 SMA N.C. GND VS RF OUT No Connection Ground Supply Voltage RF Output Environmental conditions Test IEC 60068 Part ... IEC 60679-1 clause ... 4.3 Visual inspection, dimensions Solderability Resistance to soldering heat Shock* 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXE1000 page 2(2) .axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]