AXTAL AXIS45

Issue: 01
Date: 2006-07-11
Specification
AXIS45
Oscillator type : Wideband VCXO in double-sealed DIL package
Direct replacement of Fujitsu M2 (F100)
Parameter
min.
max.
Unit
Frequency range
Standard frequencies
5
30
16.384 / 24.576 / 27.000 /
28.224
MHz
MHz
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range
vs. supply voltage variation
vs. load change
long term (aging)
Frequency adjustment range
Electronic Frequency Control (EFC)
(Pulling range)
See Note 2
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Start-up time
Supply voltage VS
typ.
ppm
ppm
ppm
± 100
± 500
± 1000
± 1500*
± 2000*
± 2500*
± 3000*
0.25
0.15
Condition
-20°C ~+70°C
± 10
±5
± 10
ppm
ppm
ppm/year @ 40°C
4.75
3.15
ppm
ppm
ppm
ppm
ppm
ppm
V
v
Option 2 = “ ”
Option 2 = “1000”
Option 2 = “1500” *
Option 2 = “2000” *
Option 2 = “2500” *
Option 2 = “3000” *
Option 1 = “50“ (5 V)
Option 1 = “33” (3.3 V)
positive
%
kΩ
100
HCMOS
15
Current consumption
Operating temperature range
Operable temperature range
Storage temperature range
Enclosure (see drawing) LxWxH
Weight
Packing
ESD Sensitivity
RoHS compliance
10
40
60
4
4.75
5.0
5.25
3.13
3.3
3.47
30
-20
+70
-40
+85
-45
+90
20.7x13.1x7.5 max.
3
sticks
1500
Full
pF
ns
%
ms
V
V
mA
°C
°C
°C
mm
gram
V
@ VS/2
Option 1 = “50“ (5 V)
Option 1 = “33” (3.3 V)
@ +25°C
IEC 60679-3 CO 02
IEC 60286-3
HBM, IEC 61000-4-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. *Pulling Range Option 3 > 1000 only possible with EFC voltage 0.25V ~ 4.75 V
Ordering Code:
Model (Specification)
AXIS45
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option 1
Supply
50
Option 2
Pulling Range
2000
AXIS45
page 1(2)
Frequency [MHz]
28.224
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin #
1
7
8
14
Symbol
VC
GND
RF OUT
VS
Function
Control Voltage (EFC)
Ground
RF Output
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIS45
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]