AXTAL AXIOM10

Issue: 04
Specification
AXIOM10
Oscillator type :
OCXO in SMD package
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature (steady state)
10
operating temperature range
-40
-20
-10
vs. supply voltage variation
vs. load change
long term (aging) 1st year
@ +40°C, after 30 days
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Warm-up time
Phase noise
@12.8 MHz
max.
Unit
Condition
Note 2
± 200
MHz
MHz
ppm
ppb
ppb
ppb
ppb
°C
°C
°C
ppb
ppb
ppb
3.15
4.5
ppm
V
V
120
10.0 / 12.8 / 19.44
± 500
± 200
± 100
± 50
+80
+70
+60
± 10
± 10
±2
0.15
0.25
1.65
2.5
positive
100
5
60
5
40
3.15
4.75
Current consumption
(steady state, @ +25°C)
Current consumption (warm-up)
@+25°C, VC= center
Option II = “200”
Option II = “100”
Option II = “50”
Option II = “200”
Option II = “100”
Option II = “50”
Option I = “33”
Option I = “50”
kΩ
HCMOS
15
Supply voltage VS
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
typ.
Date: 2005-07-15
-95
-120
-140
-145
3.3
5.0
3.45
5.25
300
250
800
500
-45
+85
25.6x22.2x11.5 max.
9
Bulk, Tape & reel
1500
pF
ns
%
min
dBc
dBc
dBc
dBc
V
V
mA
mA
mA
mA
°C
mm
gram
V
@ VS/2
∆ffinal/f0 < ±0.1 ppm
10 Hz
100 Hz
1000 Hz
10000 Hz
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
IEC 61837 CO 28
IEC 60286-3
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Not all combinations of options available in the whole frequency range
Ordering Code:
Model (Specification)
AXIOM10
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option I Option II Frequency [MHz]
50
100
10.0
AXIOM10
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing:
Pin connections
Pin # Symbol
1
VC
2
VREF
3
VS
4
RF OUT
5
N.C.
6
N.C.
7
GND
Function
Control Voltage (EFC)
Reference Voltage
Supply Voltage
RF Output
No Connection
No Connection
Ground
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM10
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836