AXTAL AXIOM20S

Issue: 04
Date: 2008-04-04
Specification
AXIOM20S
Oscillator type :
OCXO in DIL14 package with Stratum III stability
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range
operating temperature range
typ.
max.
Unit
Condition
10
20
12.8 / 16.384 / 19.44 / 20.0
MHz
MHz
ppm
ppb
ppb
@+25°C
steady state
± 500
± 280
0
-20
-40
vs. supply voltage variation
vs. load change
Holdover stability (over operating
temperature range and VS ± 1 %)
24 hours drift
long term (aging) 1st year
Long term aging over 15 years
Long term stability (overall) 15 years
Frequency adjustment range
Mechanical (internal trimmer)
Electronic Frequency Control (EFC)
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Warm-up time
Supply voltage VS
70
70
85
± 40
± 0.8
± 3.5
± 4.6
ppb
ppm
ppm
ppm
± 10
± 10
HCMOS
15
40
3.13
4.75
3.3
5.0
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
Enable/disable function
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
± 0.37
°C
°C
°C
ppb
ppb
ppm
10
60
5
3.47
5.25
300
250
800
500
-45
+90
-45
+90
20.7 x 13.1 x 11 max.
5
Palette
1500
Option II = “070”
Option II = “2070”
Option II = “4085”
TELCORDIA GR-1244
CORE Stratum III or
ITU-T G.813 option 1
@ +40°C, after 30 days
Note 2
ppm
ppm
N.A.
N.A.
pF
ns
%
min
V
V
mA
mA
mA
mA
@ VS/2
∆ffinal/f0 < ±0.5 ppm
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
°C
°C
mm
gram
V
IEC 60679-3 CO 02
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Overall frequency stability = initial tolerance + temp.stability + supply & load change + aging
Ordering Code:
Model (Specification)
AXIOM20S
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option I
33
Option II
070
Frequency [MHz]
12.800
AXIOM20S
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
N.C.
7
GND
8
RF OUT
14
Vs
Function
No Connection
Ground
RF Output
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM20S
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836