OMRON G6S-2

Low Signal Relay
■
■
■
■
■
G6S
Third generation surface mount design
Design is based on worldwide telecommunications, data communications,
computer peripheral and office automation relay requirements
High dielectric withstand voltage of 2,000
VAC between coil and contacts (standard type)
Meets 2.5kV Bellcore surge requirement
Offers significant board space savings
European version certified for EN60950/
EN41003 Supplementary Insulation at
250 V
■ Available in PCB through-hole terminal
configuration
■ Tape and reel packaging option available
■
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6S-2F-DC12).
■ STANDARD VERSION
Part number
Terminal
Gull-wing
Inside “L”
PCB through-hole
Contact form
DPDT
DPDT
DPDT
Non-latching
G6S-2F
G6S-2G
G6S-2
Single coil latching
G6SU-2F
G6SU-2G
G6SU-2
■ EUROPEAN VERSION
Certified for EN60950/EN41003 Supplementaty Insulation at 250 V
Terminal
Gull-wing
Inside “L”
PCB through-hole
Contact form
DPDT
DPDT
DPDT
Part number
Non-latching
G6S-2F-Y
G6S-2G-Y
G6S-2-Y
Dual coil latching
G6SK-2F
G6SK-2G
G6SK-2
High-sensitivity
dual coil latching
G6SK-2F-H
G6SK-2G-H
G6SK-2-H
G6S
G6S
Specifications
■ CONTACT DATA
Load
Rated load
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
Resistive load (cos ø = 1)
0.5 A at 125 VAC
2 A at 30 VAC
Ag (Au clad)
2A
250 VAC, 220 VDC
2A
62.5 VA, 60 W
10 mVDC, 10 µA
■ COIL DATA
G6S – Standard non-latching (G6S-2F, G6S-2G, G6S-2)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Pick-up
voltage
3
4.5
5
6
9
12
24
46.7
31.0
28.1
23.3
15.5
11.7
8.3
64.3
145
178
257
579
1,028
2,880
75% max.
75% max.
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
10% min.
200% max.
140
10% min.
170% max.
200
Maximum
voltage
% of rated voltage
75% max.
75% max.
Power
consumption
(mW)
180% max.
100
75% max.
180% max.
150
Set pick-up
voltage
Reset pick-up
voltage
% of rated voltage
G6SU – Standard single coil latching (G6SU-2F, G6SU-2G, G6SU-2)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
4.5
5
6
9
12
24
33.3
22.2
20.0
16.7
11.1
8.3
6.3
90
203
250
360
810
1,440
3,840
Set pick-up
voltage
Reset pick-up
voltage
75% max.
G6SK – Standard dual coil latching (G6SK-2F, G6SK-2G, G6SK-2)
2
Set coil
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Reset coil
Rated
current
(mA)
Coil
resistance
(Ω)
3
4.5
5
6
9
12
24
66.6
44.4
40.0
33.3
22.2
16.7
12.5
45
101
125
180
405
720
1,920
66.6
44.4
40.0
33.3
22.2
16.7
12.5
45
101
125
180
405
720
1,920
Maximum
voltage
% of rated voltage
75% max.
75% max.
Power
consumption
(mW)
170% max.
200
75% max.
140% max.
300
75% max.
G6S
G6S
■ COIL DATA (continued)
G6SK – Standard high-sensitivity dual coil latching (G6SK-2F-H, G6SK-2G-H, G6SK-2-H)
Set coil
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Reset coil
Rated
current
(mA)
Coil
resistance
(Ω)
3
4.5
5
6
9
12
24
46.7
31.0
28.1
23.3
15.6
11.7
8.33
64.3
145
178
257
579
1,028
2,880
46.7
31.0
28.1
23.3
15.6
11.7
8.33
64.3
145
178
257
579
1,028
2,880
Set pick-up
voltage
Reset pick-up
voltage
Maximum
voltage
% of rated voltage
75% max.
75% max.
Power
consumption
(mW)
130% max.
140
75% max.
75% max.
130% max.
200
Maximum
voltage
% of rated voltage
75% max.
10% min.
Power
consumption
(mW)
130% max.
200
75% max.
110% max.
230
G6S – European version, non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y)
Rated
voltage
(DC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
4.5
5
6
9
12
24
66.7
44.6
40.0
33.3
22.2
16.7
9.58
45
101
125
180
405
720
2,504
Note: 1.
2.
3.
4.
Pick-up
voltage
Dropout
voltage
10% min.
The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
The operating characteristics are measured at a coil temperature of 23°C (73°F) unless otherwise specified.
Pick-up voltage is measured with no carry current across the contacts.
Pick-up voltage will vary with temperature.
■ CHARACTERISTICS
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Weight
75 mΩ max.
4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK)
4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK)
Approx. 0.5 ms
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts
1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
2,500 V, 2 x 10 µS (conforms to Bellcore specifications) for G6S and G6SU;
1,500 V, 10 x 160 µS (conforms to FCC part 68) for G6SK between coil and contacts
2,500 V, 2 x 10 µS (conforms to Bellcore specs.) between contacts of different poles
1,500 V, 10 x 160 µS (conforms to FCC part 68) between contacts of same pole
10 to 55 Hz; 5 mm (0.20 in) double amplitude
10 to 55 Hz; 3.3 mm (0.13 in) double amplitude
1,000 m/s2; approx. 100 G
750 m/s2; approx. 75 G
-40 to +85°C (-40°F + 185°F)
35 to 85% RH
100,000,000 operations min. (at 36,000 operations/hour)
See "Characteristic Data"
Approx. 2g (0.07 oz)
Note: Data shown are of initial value.
3
G6S
G6S
■ CHARACTERISTIC DATA
Ambient temperature vs.
maximum coil voltage (G6S)
Maximum switching capacity
Ambient temperature vs.
maximum coil voltage (G6SU, G6SK)
10
7
250
3
AC
resistive
load
A
1
0.7
0.5
DC
resistive
load
0.3
250
3-12 VDC
Maximum coil voltage
(% of rated voltage)
Maximum coil voltage
(% of rated voltage)
Rated operating current (A)
5
200
170
150
24 VDC
100
G6SU
200
180
170
150
140
100
B
50
0.1
10
30
50 70 100
50
0
-40
300 500 700 1000
G6SK (3-12 VDC)
G6SK (24 VDC)
-20
0
20
40
60
80
0
-40
100
-20
0
80
100
0.4
0.6
0.8
Service life (x106 operations)
Resistive load: 100mA, 50 VDC
Ambient temperature: +85°
1.0
1500
2000
2500
3000
Breakdown voltage (V)
3500
Ambient temperature (°C)
Rated operating voltage (V)
A
B
DC (30V, 2A)
DC (220V, 0.27A)
AC (31.25V, 2A)
AC (250V, 0.25A)
20
40
60
Ambient temperature (°C)
Service Life
500
500
500
300
200
100
50
30
300
200
100
50
30
20
10
Contact resistance (mW)
1000
Contact resistance (mW)
1000
Contact resistance (mW)
1000
20
0
0.2
0.4
0.6
0.8
Service life (x106 operations)
Resistive load: 10mA, 10 VDC
Ambient temperature: +85°
10
1.0
Electrical service life
300
200
100
50
30
20
0
0.2
0.3
0.4
Service life (x106 operations)
Resistive load: 100mA, 28 VDC
Ambient temperature: +85°
0.1
10
0.5
0
0.2
Dielectric strength (Standard version, non-latching)
Detecting current: 1mA
500
50
50
40
40
100
70
50
30
Number of contacts (pcs.)
200
Number of contacts (pcs.)
Service life (x104 operations)
300
30
20
0
0.4
0.8
1.2
1.6
Rated operating current (A)
2.0
0
0
1000
1500
2000
2500
Breakdown voltage (V)
3000
Between coil and contacts
4
20
10
10
10
30
3500
1000
Between contacts of different poles
Between contacts of same pole
G6S
G6S
Impulse withstand voltage (Standard version, non-latching)
(2 x 10 µs)
(10 x 160 µs)
9
3
3500
4000
4500
5000
5500
Breakdown voltage (V)
Number of contacts (pcs.)
Number of contacts (pcs.)
Number of contacts (pcs.)
6
0
(10 x 160 µs)
15
9
10
5
0
1500
6000
2000
2500
3000
3500
Breakdown voltage (V)
6
3
0
4000
Between contacts of same pole
Between coil and contacts
3500
4000
4500
5000 5500
Breakdown voltage (V)
6000
Between coil and contacts
Between contacts of different poles
Impulse withstand voltage (European version)
(10 x160 µs)
(10 x 160µs)
6
3
4000
4500
5000
5500
6000
Breakdown voltage (V)
10
5
0
1500
6500
9
Number of contacts (pcs.)
Number of contacts (pcs.)
Number of contacts (pcs.)
9
0
(2 x 10 µs)
15
2000
2500
3000
Breakdown voltage (V)
3500
4000
Between contacts of same pole
Between coil and contacts
Between contacts of different poles
6
3
0
4000
4500
5000
5500 6000
Breakdown voltage (V)
6500
Between coil and contacts
Between contacts of different poles
50
50
40
40
Number of contacts (pcs.)
Number of contacts (pcs.)
Dielectric strength (European version, non-latching)
Detecting current: 1mA
30
20
10
30
20
10
0
0
1500
2000
2500
3000
3500
Breakdown voltage (V)
Between coil and contacts
4000
1500
2000
2500
3000
3500
Breakdown voltage (V)
Between contacts of different poles
Between contacts of same pole
4000
5
G6S
G6S
Dimensions
Unit: mm (inch)
■ STANDARD
G6S-2F,
G6S-2F-Y
Terminal arrangement/
Internal connections
(Top view)
7.3 ±0.2
(.287) max.
14.8 ±0.2
(.583) max.
12
G
12 6S
V 2F
D
C
N
IN
95°
0.25
(.01)
2.54
(.10)
1.25 ±0.2
(.05)
9.2 +0.5
-0.3
2.54
(.10)
7.3 ±0.2
(.287) max.
12
9.2 ±0.2
(.362) .65
max. (.026)
0.25
(.01)
1.25 ±0.2
(.05)
2.54
(.10)
14.8 ±0.2
(.583) max.
G
12 6S
V 2-Y
D
C
5.08 2.54 2.54
(.20) (.10) (.10)
10
9
8
6.1
2.2 (.24)
(.087)
1
3
4
5
95°
2.54
(.10)
1.0
(.039)
4.9 +0.3
-0.5
Terminal arrangement/
Internal connections
(Bottom view)
P
AN
JA
7.3 ±0.2
(.287) max.
9.2 ±0.2 .65
(.362) (.026)
max.
3
4
5
+
12
.50
(.019)
2.54 1.25 ±0.2
(.10) (.05)
2.54
(.10)
4.9 +0.3
-0.5
Mounting holes
(Bottom view)
2.54
(.10)
Orientation mark
1
5.08
(.20)
Mounting pads
(Top view)
+
G6S-2,
G6S-2-Y
6
5
_
°
.50
(.019)
5.08
(.20)
IN
4
Orientation mark
±4
G
12 6S
V 2G
D
C
PA
JA
M
E
3
1.0
(.039)
N
AD
8.0
2.2 (.315)
(.087)
Terminal arrangement/
Internal connections
(Top view)
14.8 ±0.2
(.583) max.
M
8
+
1
G6S-2G,
G6S-2G-Y
IN
9
_
±4°
.50
(.019)
5.08
(.20)
E
AD
10
JA
9.2 ±0.2 .65
(.362) (.026)
max.
5.08 2.54 2.54
(.20) (.10) (.10)
Orientation mark
PA
E
AD
M
Mounting pads
(Top view)
8 -ø 1 dia.
holes
2.54
(.10)
5.08
(.20)
10
9
8
10. 16 ± 0.1
1.0
(.039)
1.11
(.04)
G6S
G6S
■ SINGLE COIL LATCHING
Terminal arrangement/
Internal connections
(Top view)
G6SU-2F
7.3 ±0.2
(.287) max.
14.8 ±0.2
(.583) max.
12
N
G
12 6S
U
V -2
D F
C
IN
JA
9.2 ±0.2 .65
(.362) (.026)
max.
0.25
(.01)
2.54
(.10)
1.25 ±0.2
(.05)
2.54
(.10)
9.2
7.3 ±0.2
(.287) max.
2.54
(.10)
5.08 2.54 2.54
(.20) (.10) (.10)
10
9
8
6.1
2.2 (.24)
(.087)
SR
+_
°
0.25
(.01)
1.25 ±0.2
(.05)
2.54
(.10)
±4
G
12 6S
U
V -2
D G
C
Mounting pads
(Top view)
1
3
4
5
95°
4.9
1.0
(.039)
+0.3
-0.5
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Bottom view)
7.3 ±0.2
(.287) max.
PA
JA
9.2 ±0.2 .65
(.362) (.026)
max.
5.08
(.20)
3
4
5
+SR
-+
12
.50
(.019)
0.25
(.01)
2.54
(.10)
2.54
(.10)
5.08
(.20)
2.54
(.10)
Orientation mark
1
N
■
G
12 6S
U
V -2
D C ■
5
_+
14.8 ±0.2
(.583) max.
IN
4
Orientation mark
12
9.2 ±0.2
(.362) .65
max. (.026)
G6SU-2
E
3
1.0
(.039)
N
.50
(.019)
5.08
(.20)
AD
8.0
2.2 (.315)
(.087)
SR
+_
1
PA
JA
M
M
8
Terminal arrangement/
Internal connections
(Top view)
14.8 ±0.2
(.583) max.
IN
9
+0.5
-0.3
G6SU-2G
E
AD
10
_+
95°
±4°
.50
(.019)
5.08
(.20)
5.08 2.54 2.54
(.20) (.10) (.10)
Orientation mark
PA
E
AD
M
Mounting pads
(Top view)
8 -ø 1 dia.
holes
2.54
(.10)
5.08
(.20)
10
9
8
10. 16 ± 0.1
1.0
(.039)
1.11
(.04)
7
G6S
G6S
Unit: mm (inch)
■
DUAL COIL LATCHING
Terminal arrangement/
Internal connections
(Top view)
G6SK-2F,
G6SK-2F-H
7.3 ±0.2
(.287) max.
14.8 ±0.2
(.583) max.
5.08 2.54 2.54
(.20) (.10) (.10)
Orientation mark
12
G
12 6S
K
V -2
D F
C
N
E
IN
A
AP
J
95°
0.25
(.01)
2.54
(.10)
2.54 2.54
(.10) (.10)
1.25 ±0.2
(.05)
9.2
7.3 ±0.2
(.287) max.
12
2.54 2.54
(.10) (.10)
G
12 6S
K
V -2
D -■
C ■
M
1
6.1
2.2 (.24)
(.087)
R
+
3
4
5 6
95°
1.0
(.039)
4.9 +0.3
-0.5
9.2 ±0.2 .65
(.362) (.026)
max.
5.08
(.20)
3
4
5 6
+
S
12
0.25
(.01)
2.54 2.54
(.10) (.10)
2.54
(.10)
5.08
(.20)
Note: 1. 123456
Coplanarity is 0.1 mm max.
123456
123456
2.
and
indicate mounting orientation marks.
10 - ø 1 dia.
holes
Orientation mark
1
N
Mounting holes
(Bottom view)
2.54
(.10)
7.3 ±0.2
(.287) max.
PA
JA
.50
(.019)
8
_
Terminal arrangement/
Internal connections
(Bottom view)
14.8 ±0.2
(.583) max.
2.54
(.10)
10 9 8 7
+
°
0.25
(.01)
1.25 ±0.2
(.05)
2.54
(.10)
Mounting pads
(Top view)
5.08 2.54
(.20) (.10)
S
G6SK-2,
G6SK-2-H
IN
5 6
_
9.2 ±0.2
(.362) .65
max. (.026)
.50
(.019)
5.08
(.20)
E
AD
4
Orientation mark
N
JA
3
1.0
(.039)
PA
IN
8.0
2.2 (.315)
(.087)
R
+
+0.5
-0.3
±4
G
12 6S
K
V -2
D G
C
E
_
Terminal arrangement/
Internal connections
(Top view)
14.8 ±0.2
(.583) max.
AD
7
+
1
G6SK-2G,
G6SK-2G-H
M
9 8
S
±4°
.50
(.019)
5.08
(.20)
10
_
9.2 ±0.2 .65
(.362) (.026)
max.
AD
M
Mounting pads
(Top view)
+
R
10 9 8
2.54
(.10)
5.08
(.20)
7
1.0
(.039)
12..7±0.1
1.11
(.04)
G6S
G6S
■ ACCESSORIES
Tube packing
Tape packing
Standard nomenclature
50 pcs per anti-static tube
When ordering, add “TR” before the rated coil voltage (e.i., G6S-2F-TR-DC12)
Note: TR is not part of the relay model number and will not be marked on the relay
■ DIMENSIONS
Relays per reel: 400
Reels per packing carton: 2 (800 relays)
+2
24.4.-0
(.961)
2±0.5
(.0.79)
29.4±1.0 (1.16)
Orientation mark
21±0.8
(.827)
Feed
direction
Cover tape
330
(12.99)
80
(3.15)
R1.0
13±0.2
(.512)
Carrier tape
Emboss tape
■ APPROVALS
UL (File No. E41515)/ CSA (File No. LR24825)
Type
G6S-2F
G6S-2F-Y
G6S-2G
G6S-2G-Y
G6S-2
G6S-2-Y
G6SU-2F
G6SU-2G
G6SU-2
G6SK-2F
G6SK-2G
G6SK-2
G6SK-2F-H
G6SK-2G-H
G6SK-2-H
Contact Form
DPDT
Coil Rating
1.5 to 48 VDC
Contact Ratings
0.5 A, 125 VAC
0.3 A, 110 VDC
2.0 A, 30 VDC
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance
characteristics individually defined in this catalog.
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY6
9/97
Specifications subject to change without notice.
Printed in the U.S.A.
9