Low Signal Relay ■ ■ ■ ■ ■ G6S Third generation surface mount design Design is based on worldwide telecommunications, data communications, computer peripheral and office automation relay requirements High dielectric withstand voltage of 2,000 VAC between coil and contacts (standard type) Meets 2.5kV Bellcore surge requirement Offers significant board space savings European version certified for EN60950/ EN41003 Supplementary Insulation at 250 V ■ Available in PCB through-hole terminal configuration ■ Tape and reel packaging option available ■ Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G6S-2F-DC12). ■ STANDARD VERSION Part number Terminal Gull-wing Inside “L” PCB through-hole Contact form DPDT DPDT DPDT Non-latching G6S-2F G6S-2G G6S-2 Single coil latching G6SU-2F G6SU-2G G6SU-2 ■ EUROPEAN VERSION Certified for EN60950/EN41003 Supplementaty Insulation at 250 V Terminal Gull-wing Inside “L” PCB through-hole Contact form DPDT DPDT DPDT Part number Non-latching G6S-2F-Y G6S-2G-Y G6S-2-Y Dual coil latching G6SK-2F G6SK-2G G6SK-2 High-sensitivity dual coil latching G6SK-2F-H G6SK-2G-H G6SK-2-H G6S G6S Specifications ■ CONTACT DATA Load Rated load Contact material Max. carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (cos ø = 1) 0.5 A at 125 VAC 2 A at 30 VAC Ag (Au clad) 2A 250 VAC, 220 VDC 2A 62.5 VA, 60 W 10 mVDC, 10 µA ■ COIL DATA G6S – Standard non-latching (G6S-2F, G6S-2G, G6S-2) Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Pick-up voltage 3 4.5 5 6 9 12 24 46.7 31.0 28.1 23.3 15.5 11.7 8.3 64.3 145 178 257 579 1,028 2,880 75% max. 75% max. Dropout voltage Maximum voltage Power consumption (mW) 10% min. 200% max. 140 10% min. 170% max. 200 Maximum voltage % of rated voltage 75% max. 75% max. Power consumption (mW) 180% max. 100 75% max. 180% max. 150 Set pick-up voltage Reset pick-up voltage % of rated voltage G6SU – Standard single coil latching (G6SU-2F, G6SU-2G, G6SU-2) Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 3 4.5 5 6 9 12 24 33.3 22.2 20.0 16.7 11.1 8.3 6.3 90 203 250 360 810 1,440 3,840 Set pick-up voltage Reset pick-up voltage 75% max. G6SK – Standard dual coil latching (G6SK-2F, G6SK-2G, G6SK-2) 2 Set coil Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Reset coil Rated current (mA) Coil resistance (Ω) 3 4.5 5 6 9 12 24 66.6 44.4 40.0 33.3 22.2 16.7 12.5 45 101 125 180 405 720 1,920 66.6 44.4 40.0 33.3 22.2 16.7 12.5 45 101 125 180 405 720 1,920 Maximum voltage % of rated voltage 75% max. 75% max. Power consumption (mW) 170% max. 200 75% max. 140% max. 300 75% max. G6S G6S ■ COIL DATA (continued) G6SK – Standard high-sensitivity dual coil latching (G6SK-2F-H, G6SK-2G-H, G6SK-2-H) Set coil Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Reset coil Rated current (mA) Coil resistance (Ω) 3 4.5 5 6 9 12 24 46.7 31.0 28.1 23.3 15.6 11.7 8.33 64.3 145 178 257 579 1,028 2,880 46.7 31.0 28.1 23.3 15.6 11.7 8.33 64.3 145 178 257 579 1,028 2,880 Set pick-up voltage Reset pick-up voltage Maximum voltage % of rated voltage 75% max. 75% max. Power consumption (mW) 130% max. 140 75% max. 75% max. 130% max. 200 Maximum voltage % of rated voltage 75% max. 10% min. Power consumption (mW) 130% max. 200 75% max. 110% max. 230 G6S – European version, non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y) Rated voltage (DC) Rated current (mA) Coil resistance (Ω) 3 4.5 5 6 9 12 24 66.7 44.6 40.0 33.3 22.2 16.7 9.58 45 101 125 180 405 720 2,504 Note: 1. 2. 3. 4. Pick-up voltage Dropout voltage 10% min. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%. The operating characteristics are measured at a coil temperature of 23°C (73°F) unless otherwise specified. Pick-up voltage is measured with no carry current across the contacts. Pick-up voltage will vary with temperature. ■ CHARACTERISTICS Contact resistance Operate (set) time Release (reset) time Bounce time Insulation resistance Dielectric strength Surge withstand voltage Vibration Shock Ambient temperature Humidity Service life Mechanical durability Malfunction durability Mechanical durability Malfunction durability Mechanical Electrical Weight 75 mΩ max. 4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK) 4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK) Approx. 0.5 ms 1,000 MΩ min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts 1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles 1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole 2,500 V, 2 x 10 µS (conforms to Bellcore specifications) for G6S and G6SU; 1,500 V, 10 x 160 µS (conforms to FCC part 68) for G6SK between coil and contacts 2,500 V, 2 x 10 µS (conforms to Bellcore specs.) between contacts of different poles 1,500 V, 10 x 160 µS (conforms to FCC part 68) between contacts of same pole 10 to 55 Hz; 5 mm (0.20 in) double amplitude 10 to 55 Hz; 3.3 mm (0.13 in) double amplitude 1,000 m/s2; approx. 100 G 750 m/s2; approx. 75 G -40 to +85°C (-40°F + 185°F) 35 to 85% RH 100,000,000 operations min. (at 36,000 operations/hour) See "Characteristic Data" Approx. 2g (0.07 oz) Note: Data shown are of initial value. 3 G6S G6S ■ CHARACTERISTIC DATA Ambient temperature vs. maximum coil voltage (G6S) Maximum switching capacity Ambient temperature vs. maximum coil voltage (G6SU, G6SK) 10 7 250 3 AC resistive load A 1 0.7 0.5 DC resistive load 0.3 250 3-12 VDC Maximum coil voltage (% of rated voltage) Maximum coil voltage (% of rated voltage) Rated operating current (A) 5 200 170 150 24 VDC 100 G6SU 200 180 170 150 140 100 B 50 0.1 10 30 50 70 100 50 0 -40 300 500 700 1000 G6SK (3-12 VDC) G6SK (24 VDC) -20 0 20 40 60 80 0 -40 100 -20 0 80 100 0.4 0.6 0.8 Service life (x106 operations) Resistive load: 100mA, 50 VDC Ambient temperature: +85° 1.0 1500 2000 2500 3000 Breakdown voltage (V) 3500 Ambient temperature (°C) Rated operating voltage (V) A B DC (30V, 2A) DC (220V, 0.27A) AC (31.25V, 2A) AC (250V, 0.25A) 20 40 60 Ambient temperature (°C) Service Life 500 500 500 300 200 100 50 30 300 200 100 50 30 20 10 Contact resistance (mW) 1000 Contact resistance (mW) 1000 Contact resistance (mW) 1000 20 0 0.2 0.4 0.6 0.8 Service life (x106 operations) Resistive load: 10mA, 10 VDC Ambient temperature: +85° 10 1.0 Electrical service life 300 200 100 50 30 20 0 0.2 0.3 0.4 Service life (x106 operations) Resistive load: 100mA, 28 VDC Ambient temperature: +85° 0.1 10 0.5 0 0.2 Dielectric strength (Standard version, non-latching) Detecting current: 1mA 500 50 50 40 40 100 70 50 30 Number of contacts (pcs.) 200 Number of contacts (pcs.) Service life (x104 operations) 300 30 20 0 0.4 0.8 1.2 1.6 Rated operating current (A) 2.0 0 0 1000 1500 2000 2500 Breakdown voltage (V) 3000 Between coil and contacts 4 20 10 10 10 30 3500 1000 Between contacts of different poles Between contacts of same pole G6S G6S Impulse withstand voltage (Standard version, non-latching) (2 x 10 µs) (10 x 160 µs) 9 3 3500 4000 4500 5000 5500 Breakdown voltage (V) Number of contacts (pcs.) Number of contacts (pcs.) Number of contacts (pcs.) 6 0 (10 x 160 µs) 15 9 10 5 0 1500 6000 2000 2500 3000 3500 Breakdown voltage (V) 6 3 0 4000 Between contacts of same pole Between coil and contacts 3500 4000 4500 5000 5500 Breakdown voltage (V) 6000 Between coil and contacts Between contacts of different poles Impulse withstand voltage (European version) (10 x160 µs) (10 x 160µs) 6 3 4000 4500 5000 5500 6000 Breakdown voltage (V) 10 5 0 1500 6500 9 Number of contacts (pcs.) Number of contacts (pcs.) Number of contacts (pcs.) 9 0 (2 x 10 µs) 15 2000 2500 3000 Breakdown voltage (V) 3500 4000 Between contacts of same pole Between coil and contacts Between contacts of different poles 6 3 0 4000 4500 5000 5500 6000 Breakdown voltage (V) 6500 Between coil and contacts Between contacts of different poles 50 50 40 40 Number of contacts (pcs.) Number of contacts (pcs.) Dielectric strength (European version, non-latching) Detecting current: 1mA 30 20 10 30 20 10 0 0 1500 2000 2500 3000 3500 Breakdown voltage (V) Between coil and contacts 4000 1500 2000 2500 3000 3500 Breakdown voltage (V) Between contacts of different poles Between contacts of same pole 4000 5 G6S G6S Dimensions Unit: mm (inch) ■ STANDARD G6S-2F, G6S-2F-Y Terminal arrangement/ Internal connections (Top view) 7.3 ±0.2 (.287) max. 14.8 ±0.2 (.583) max. 12 G 12 6S V 2F D C N IN 95° 0.25 (.01) 2.54 (.10) 1.25 ±0.2 (.05) 9.2 +0.5 -0.3 2.54 (.10) 7.3 ±0.2 (.287) max. 12 9.2 ±0.2 (.362) .65 max. (.026) 0.25 (.01) 1.25 ±0.2 (.05) 2.54 (.10) 14.8 ±0.2 (.583) max. G 12 6S V 2-Y D C 5.08 2.54 2.54 (.20) (.10) (.10) 10 9 8 6.1 2.2 (.24) (.087) 1 3 4 5 95° 2.54 (.10) 1.0 (.039) 4.9 +0.3 -0.5 Terminal arrangement/ Internal connections (Bottom view) P AN JA 7.3 ±0.2 (.287) max. 9.2 ±0.2 .65 (.362) (.026) max. 3 4 5 + 12 .50 (.019) 2.54 1.25 ±0.2 (.10) (.05) 2.54 (.10) 4.9 +0.3 -0.5 Mounting holes (Bottom view) 2.54 (.10) Orientation mark 1 5.08 (.20) Mounting pads (Top view) + G6S-2, G6S-2-Y 6 5 _ ° .50 (.019) 5.08 (.20) IN 4 Orientation mark ±4 G 12 6S V 2G D C PA JA M E 3 1.0 (.039) N AD 8.0 2.2 (.315) (.087) Terminal arrangement/ Internal connections (Top view) 14.8 ±0.2 (.583) max. M 8 + 1 G6S-2G, G6S-2G-Y IN 9 _ ±4° .50 (.019) 5.08 (.20) E AD 10 JA 9.2 ±0.2 .65 (.362) (.026) max. 5.08 2.54 2.54 (.20) (.10) (.10) Orientation mark PA E AD M Mounting pads (Top view) 8 -ø 1 dia. holes 2.54 (.10) 5.08 (.20) 10 9 8 10. 16 ± 0.1 1.0 (.039) 1.11 (.04) G6S G6S ■ SINGLE COIL LATCHING Terminal arrangement/ Internal connections (Top view) G6SU-2F 7.3 ±0.2 (.287) max. 14.8 ±0.2 (.583) max. 12 N G 12 6S U V -2 D F C IN JA 9.2 ±0.2 .65 (.362) (.026) max. 0.25 (.01) 2.54 (.10) 1.25 ±0.2 (.05) 2.54 (.10) 9.2 7.3 ±0.2 (.287) max. 2.54 (.10) 5.08 2.54 2.54 (.20) (.10) (.10) 10 9 8 6.1 2.2 (.24) (.087) SR +_ ° 0.25 (.01) 1.25 ±0.2 (.05) 2.54 (.10) ±4 G 12 6S U V -2 D G C Mounting pads (Top view) 1 3 4 5 95° 4.9 1.0 (.039) +0.3 -0.5 Mounting holes (Bottom view) Terminal arrangement/ Internal connections (Bottom view) 7.3 ±0.2 (.287) max. PA JA 9.2 ±0.2 .65 (.362) (.026) max. 5.08 (.20) 3 4 5 +SR -+ 12 .50 (.019) 0.25 (.01) 2.54 (.10) 2.54 (.10) 5.08 (.20) 2.54 (.10) Orientation mark 1 N ■ G 12 6S U V -2 D C ■ 5 _+ 14.8 ±0.2 (.583) max. IN 4 Orientation mark 12 9.2 ±0.2 (.362) .65 max. (.026) G6SU-2 E 3 1.0 (.039) N .50 (.019) 5.08 (.20) AD 8.0 2.2 (.315) (.087) SR +_ 1 PA JA M M 8 Terminal arrangement/ Internal connections (Top view) 14.8 ±0.2 (.583) max. IN 9 +0.5 -0.3 G6SU-2G E AD 10 _+ 95° ±4° .50 (.019) 5.08 (.20) 5.08 2.54 2.54 (.20) (.10) (.10) Orientation mark PA E AD M Mounting pads (Top view) 8 -ø 1 dia. holes 2.54 (.10) 5.08 (.20) 10 9 8 10. 16 ± 0.1 1.0 (.039) 1.11 (.04) 7 G6S G6S Unit: mm (inch) ■ DUAL COIL LATCHING Terminal arrangement/ Internal connections (Top view) G6SK-2F, G6SK-2F-H 7.3 ±0.2 (.287) max. 14.8 ±0.2 (.583) max. 5.08 2.54 2.54 (.20) (.10) (.10) Orientation mark 12 G 12 6S K V -2 D F C N E IN A AP J 95° 0.25 (.01) 2.54 (.10) 2.54 2.54 (.10) (.10) 1.25 ±0.2 (.05) 9.2 7.3 ±0.2 (.287) max. 12 2.54 2.54 (.10) (.10) G 12 6S K V -2 D -■ C ■ M 1 6.1 2.2 (.24) (.087) R + 3 4 5 6 95° 1.0 (.039) 4.9 +0.3 -0.5 9.2 ±0.2 .65 (.362) (.026) max. 5.08 (.20) 3 4 5 6 + S 12 0.25 (.01) 2.54 2.54 (.10) (.10) 2.54 (.10) 5.08 (.20) Note: 1. 123456 Coplanarity is 0.1 mm max. 123456 123456 2. and indicate mounting orientation marks. 10 - ø 1 dia. holes Orientation mark 1 N Mounting holes (Bottom view) 2.54 (.10) 7.3 ±0.2 (.287) max. PA JA .50 (.019) 8 _ Terminal arrangement/ Internal connections (Bottom view) 14.8 ±0.2 (.583) max. 2.54 (.10) 10 9 8 7 + ° 0.25 (.01) 1.25 ±0.2 (.05) 2.54 (.10) Mounting pads (Top view) 5.08 2.54 (.20) (.10) S G6SK-2, G6SK-2-H IN 5 6 _ 9.2 ±0.2 (.362) .65 max. (.026) .50 (.019) 5.08 (.20) E AD 4 Orientation mark N JA 3 1.0 (.039) PA IN 8.0 2.2 (.315) (.087) R + +0.5 -0.3 ±4 G 12 6S K V -2 D G C E _ Terminal arrangement/ Internal connections (Top view) 14.8 ±0.2 (.583) max. AD 7 + 1 G6SK-2G, G6SK-2G-H M 9 8 S ±4° .50 (.019) 5.08 (.20) 10 _ 9.2 ±0.2 .65 (.362) (.026) max. AD M Mounting pads (Top view) + R 10 9 8 2.54 (.10) 5.08 (.20) 7 1.0 (.039) 12..7±0.1 1.11 (.04) G6S G6S ■ ACCESSORIES Tube packing Tape packing Standard nomenclature 50 pcs per anti-static tube When ordering, add “TR” before the rated coil voltage (e.i., G6S-2F-TR-DC12) Note: TR is not part of the relay model number and will not be marked on the relay ■ DIMENSIONS Relays per reel: 400 Reels per packing carton: 2 (800 relays) +2 24.4.-0 (.961) 2±0.5 (.0.79) 29.4±1.0 (1.16) Orientation mark 21±0.8 (.827) Feed direction Cover tape 330 (12.99) 80 (3.15) R1.0 13±0.2 (.512) Carrier tape Emboss tape ■ APPROVALS UL (File No. E41515)/ CSA (File No. LR24825) Type G6S-2F G6S-2F-Y G6S-2G G6S-2G-Y G6S-2 G6S-2-Y G6SU-2F G6SU-2G G6SU-2 G6SK-2F G6SK-2G G6SK-2 G6SK-2F-H G6SK-2G-H G6SK-2-H Contact Form DPDT Coil Rating 1.5 to 48 VDC Contact Ratings 0.5 A, 125 VAC 0.3 A, 110 VDC 2.0 A, 30 VDC Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics individually defined in this catalog. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY6 9/97 Specifications subject to change without notice. Printed in the U.S.A. 9