CUI VAT0.25-S5-D3.3-SMT

rev.
description
features
Designed to convert fixed
voltages into isolated voltages,
the VAT0.25-SMT series is well
suited for providing board-mount
local supplies in a wide range of
applications, including mixed
analog/digital circuits, test &
measurement equip.,
process/machine controls, datacom/telecom fields, etc...
·SMT package
·internal SMD construction
·I/O isolation: 1000 V dc
·no heatsink required
·no external component required
·industry standard pinout
·temperature range: -40°C~+85°C
input voltage
nominal
range.
(V dc)
(V dc)
VAT0.25-S5-D3.3-SMT
VAT0.25-S5-D5-SMT
VAT0.25-S5-D9-SMT
VAT0.25-S5-D12-SMT
VAT0.25-S5-D15-SMT
VAT0.25-S12-D5-SMT
VAT0.25-S12-D9-SMT
VAT0.25-S12-D12-SMT
VAT0.25-S12-D15-SMT
VAT0.25-S24-D5-SMT
VAT0.25-S24-D9-SMT
VAT0.25-S24-D12-SMT
VAT0.25-S24-D15-SMT
notes:
5
5
5
5
5
12
12
12
12
24
24
24
24
1.
2.
1 of 3
date
date
02/2008
DESCRIPTION: dc-dc converter
PART NUMBER: VAT0.25-SMT Series
MODEL
page
page
4.5~5.5
4.5~5.5
4.5~5.5
4.5~5.5
4.5~5.5
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
output voltage
output current
max.
min.
(mA)
(mA)
(V dc)
±3.3
±5
±9
±12
±15
±5
±9
±12
±15
±5
±9
±12
±15
±38
±25
±14
±11
±9
±25
±14
±11
±9
±25
±14
±11
±9
±4
±3
±2
±2
±1
±3
±2
±2
±1
±3
±2
±2
±1
efficiency
typ.
(%)
62
64
65
67
66
65
64
63
64
61
62
63
65
All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
Unbalanced load: ±5%
OUTPUT
parameter
output power
voltage accuracy
output ripple
output noise
line regulation
conditions/description
see tolerance envelope graph
@ 20MHz Bandwidth
@ 20MHz Bandwidth
for Vin change of 1%(3.3V output)
for Vin change of 1%
10% to 100% full load
3.3V output
5V output
9V output
12V output
15V output
100% full load
100% load, nominal input(24V input)
100% load, nominal input(5V, 12V)
load regulation
temperature coefficient
switching frequency
notes:
1.
min
nom
max
0.25
units
W
50
75
75
150
±1.5
±1.2
mVpp
mVpp
%
%
15
10
6.5
6.0
6.0
20
15
15
15
15
0.03
%
%
%
%
%
%/°C
KHz
KHz
700
150
Test ripple and noise by “parallel cable” method.
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-todate product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
page
2 of 3
date
02/2008
DESCRIPTION: dc-dc converter
PART NUMBER: VAT0.25-SMT Series
GENERAL SPECIFICATIONS
parameter
output short circuit protection
temperature rise at full load
cooling
operating temp. range
storage temp. range
reflow soldering temp.
storage humidity range
case material
MTBF
conditions/description
1 second max.
15°C typ., 25°C max.
free air convection
-40°C ~ +85°C
-55°C ~ +125°C
260°C (1.5mm from case for 10 seconds)
≤95%
plastic (UL94-V0)
>3,500,000 hours
ISOLATION SPECIFICATIONS
parameter
isolation voltage
isolation resistance
conditions/description
flash tested for 1 minute
test at 500 V dc
min
1000
1000
nom
max
OUTLINE DIMENSIONS & RECOMMENDED LAYOUT PATTERN
6.76
0.50
4.25
(0.17)
(0.25 )
6.50
6.25
(0.26)
(0.2 7)
A
(Side View)
0.25
0.3
7.15
(0.07)
(0.01)
(0.2 8)
15.24 (0.6 )
7.50
2.54
10 9 8
(0.30)
(0.44)
11.2 MAX
10.16 (0.4)
7 6
(Top View)
0.1
0.6 0.05
(0.1 0.004)
(0.02
0.00 2)
5.00"
(0.06)
1.85MAX
(0.0 1)
(0.0 2)
1.35MAX
1 2
3
4
5
Pin
Function
1
2
3
4
5
6
7
8
9
10
-Vin
+Vin
NC
Com
-Vout
NC
+Vout
NC
NC
NC
Note: All Pins on a 2.54mm(0.1) pitch; All Pin Widths are 0.60 mm(0.02);
Tolerances:±0.15mm(0.006); Unit: mm(inch)
TYPICAL CHARACTERISTICS
Tolerance Envelope Graph
Temperature Derating Graph
Typica
l
Output Voltage
+5%
Nominal
Voltage
Load L
ine
+2.5%
-2.5%
-7.5%
Output Power (%)
120
+10%
100
80
60
40
20
0
10%
50%
Output Current (%)
100%
Safe Operating Area
-40
0
40
80
120
Ambient Temperature(°C)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
units
V dc
MΩ
page
3 of 3
date
02/2008
DESCRIPTION: dc-dc converter
PART NUMBER: VAT0.25-SMT Series
Application Notes:
- To ensure this module can operate efficiently and
- Output Voltage Regulation and Over-voltage
reliably during operation, the minimum output load
Protection Circuit
should not be less than 10% of the full load. This
The simplest device for output voltage regulation,
product should never be operated under no load
over-voltage and over-current protection is a linear
conditions. If the actual output power is very low you
voltage regulator with overheat protection that is
should increase the load by connecting a resistor
connected to the input or output end in series
with the proper resistance at the output end in
(Figure 2).
parallel.
No parallel connection or plug and play.
- Overload Protection
Under normal operating conditions, the output circuit
Figure 2
of these products has no protection against overload.
The simplest method is to connect a self-recovery
+Vin
fuse in series at the input end or add a circuit
+Vout
REG
Com
DC DC
breaker to the circuit.
-Vin
-Vout
- Recommended Circuit
If you want to further decrease the input/output
+Vout
REG
+Vin
ripple, an “LC” filtering network may be connected to
Com
DC DC
the input and output ends of the dc-dc converter, see
-Vin
(Figure 1).
-Vout
REG
Figure 1
L
L
+Vout
+Vin
C
C
-Vin
DC DC
L
Com
C
Reflow Profile
-Vout
Peak Temperature
260°C for 10 Sec. Max
250
It should also be noted that the inductance and
220°C
the frequency of the “LC” filtering network should
mutual interference. However, the capacitance of
the output filter capacitor must be proper. If the
capacitance is too large, a startup problem might
arise. It is not recommended to connect any
external capacitor in the application field .
Temperature (°C)
be staggered with the dc-dc frequency to avoid
200
90 Sec. max
(>220°C)
150
100
50
0
Time (Seconds)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382