• VPPQ-100D 100W 3, 4 Output with PFC Features ·Universal AC input / Full range ·Built-in active PFC function, PF>0.95 ·Protections:Short circuit/Over load/Over voltage ·Cooling by free air convection ·100% full load burn-in test ·Fixed switching frequency at 70KHz(Optional) ·3 year warranty CH1 CH2 CH3 CH4 DC output voltage Output V. tolerance 5V ±3% 24V ±8% 12V ±5% -12V ±5% Output rated current Output current range Ripple & noise Line regulation Load regulation DC output power Efficiency DC voltage adj. Input voltage range AC current Inrush current Leakage current Overload protection 8A 2A 0.6A 0.6A 2-15A 0.3-4A 0-1A 0-1A 100mV 200mV 100mV 100mV ±1% ±2% ±2% ±1% ±2% ±6% ±2% ±2% 102.4W 78% CH1:+10,-5% 90~264VAC 47~63Hz; 127~370VDC 1.65A/115V 0.85A/230V cold start 40A <3.5mA/240VAC 105%-135% type: Hiccup mode, recovers automatically after fault condition is removed CH1:5.75~6.75V ------±0.03% / ºC (0~50ºC) ON +5V output 1.2s,50ms,16ms @115VAC / 800ms, 50ms, 16ms @230VAC PF>0.95/230VAC, PF>0.98/115VAC 10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min. I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min. -10°C~+60% (refer to output derating curve), 20%-90% RH -20°C~+85°C, 10%-95% RH 7x4.25x1.5 inches (178x108x38 mm) 1.37 lb. (0.62 Kg) UL1950, TUV EN60950 EN55022 CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3 Over voltage protection Over temp. protection Temperature coefficient Set up, rise, hold up time Power factor Vibration Withstand voltage Isolation resistance Working temp., humidity Storage temp., humidity Dimensions Weight Safety standards EMC standards Notes: 1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient 2. Tolerance includes set up tolerance, line regulation, load regulation 3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor 4. Line regulation is measured from low line to high line at rated load 5. Load regulation is measured from 20% to 100% rated load, and oother output at 60% rated load 6. Each output provide up to maximum current, but total load cannot exceed max. output power *V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 • VPPQ-100D 100W 3, 4 Output with PFC Block Diagram Rectifiers & Filter EMI Filter & Rectifiers I/P FG Power Switching PFC Circuit Rectifiers & Filter MA & Control PWM & PFC Control Active Start Circuit Load (%) Load (%) 40 20 10 +5V Com Static Characteristics Natural Convection Cooling 0 0 +3.3V O.V.P. 17CFM Forced Air Cooling (10cm) -10 -10 Rectifiers & Filter Constant Current & Detection Circuit Output Derating 80 70 60 V3 Rectifiers & Filter (Option) PFC fosc: 67KHz PWM fosc: 134KHz 100 V4 Regulator 100 90 80 70 60 50 40 20 30 40 50 60 (Horizontal) 90 Ambient Temp. (ºC) 100 115 135 155 230 264 Input Voltage (V) 60Hz Dimensions (mm) 177.8 165.1 Terminal Pin No. Assignment CN1: JST B3P-VH PIN 1,3: AC INPUT CN2: JST B5P-VH PIN 1,2,3: DC OUTPUT V2 PIN 4: DC OUTPUT V3 PIN 5: DC OUTPUT V4 CN3: JST B8P-VH PIN 1,2,3: DC OUTPUT V1 PIN 4,5,6,7,8: DC OUTPUT COM 5 CN2 F4A/250V AC/L FG 107.95 8 1 95.25 1 AC/L CN1 +5V Adj. 4-¿3.96 40.64 Mating Connectors CN1,2,3 Mating Connector type JST VHR Series or equivalent with JST SVH-21T-1.1 or equivalent crimp terminals. +3.3V Adj. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258