CUI VAD-55A

•
VAD-55A Metal Enclosed Switching Power Supply
Features
·Universal AC input
·Short circuit, overload, overvoltage protection
·100% full load burn-in test
·Convection cooled
·Fixed switching freq. @ 45kHz
·battery low / battery polarity protection
CH1
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Over voltage protection
DC alarm signal (optional)
Temperature coefficient
Set up, rise, hold up time
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
MTBF
Notes:
1.
2.
3.
4.
5.
6.
7.
CH2
13.8V
13.4V
±1%
--3.5A
0.23A
0-4A
--100mVp-p
--±0.5%
--±0.5%
--51.38W
71%
CH1: 12-14.5V
88~264VAC 47~63Hz; 120-370VDC
1.6A/115V 1A/230V
cold start 20A/115V 40A/230V
<1mA/240VAC
105%~150% / 230VAC, pulsing (hiccup mode), auto restart
CH1: 14.49-18.63V
protection type: Hiccup mode auto restart
AC fail CH1 PIN2
battery low under charge voltage 82.5% ± 2% CN1 PIN1
normal 0.8V max. abnormal 5V±0.5V
±0.03% / °C (0~50°C) output on CH1
1.6s, 50ms, 16ms/115VAC 800ms, 50ms, 60ms / 230VAC
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
6.26x3.82x1.50 inches (159x97x38 mm) Case: 901
1.25 lbs (0.57 Kgs)
IEC950 requirement approved
CISPR22 (EN55022) class B, EN61000-4,2,3,4,5,6,8,11,
EN61000-3-2, -3 verification
304.3K hrs. min. MIL-HDBK-217F (25°C)
All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
Tolerance includes set up tolerance, line regulation, load regulation
Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
Line regulation is measured from low line to high line at rated load
Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load
Each output provides up to maximum current, but total load can not exceed maximum output power
CH2 Bat. charger voltage at no load, rated current at Bat. V=11V/22V
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise
customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for
customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s
published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258
•
VAD-55A Metal Enclosed Switching Power Supply
Block Diagram
Output Derating
Static Characteristics
Dimensions (mm)
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005