CUI VADS-5524

•
VADS-5512 Single/Double Output with Battery Charger
Features
·Low cost
·High reliability
·105°C output capacitor
·Universal AC input range
·High efficiency, low temperature rise
·Soft-start circuit, limiting AC surge current
·Short circuit, overload, battery protected
·Compact size, light weight
·100% full load burn-in test
·Built in EMI filter, low ripple noise
·Battery low / Battery polarity protections
CH1
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Over voltage protection
Temperature coefficient
Set up, rise, hold up time
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
Notes:
CH2
12V
5V
±1%
±3%
3A
3A
0-4A
0-4A
150mVp-p
100mVp-p
±0.5%
±0.5%
±0.5%
±0.5%
51W
74%
±10%
fixed
88~264VAC 47~63Hz; 124~370VDC
1.6A/115V 1A/230V
cold start 20A/115V 40A/230V
<1mA/240VAC
105%~150% / 230 VAC,
Hiccup mode, recovers automatically after fault condition is removed
CH1: 115%~135% type: pulse by pulse
±0.03% / ºC (0~50ºC)
1.6s, 50ms, 16ms/115VAC 800ms, 50ms, 60ms / 230VAC
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
6.26x3.82x1.50 inches (159x97x38 mm) Case: 901
1.26 lb. (0.57 Kgs)
UL1950, TUV EN60950 approved
CISPR22 (EN55022) CLASS B, EN61000-3-2,3; EN61000-4-2,3,4,5,6,8,11; ENV50204
1. All parameters are specified at 230VAC input, rated load, 25°C, 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load
6. Each output provides up to maximum current, but total load can not exceed maximum output power
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258
•
VADS-55-12 Single/Double Output with Battery Charger
Block Diagram
Output Derating
Static Characteristics
Dimensions (mm)
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258