HAMAMATSU R3809U-69

NEAR INFRARED MICROCHANNEL PLATEPHOTOMULTIPLIER TUBE WITH COOLER
R3809U-68/-69 WITH C10221
Compact NIR MCP-PMT Series Featuring with Fast Time Response
FEATURES
●High Speed
Rise Time: 170 ps (Typ.)
TTS (Transit Time Spread): 100 ps (FWHM) A
●Compact Profile
Effective Photocathode Area: 2 mm diameter
(Overall length: 72.2 mm, Outer diameter: 45.0 mm)
APPLICATIONS
▲R3809U-68/-69
TPMHF0499
▲C10221
TACCF0194
●Molecular Science
Analysis of Molecular Structure
●Medical Science
Optical Computer Tomography
●Biochemistry
Fast Gene Sequencing
●Material Engineering
Semiconductor Analysis
Crystal Research
Figure 1: Spectral Response
Figure 2: Typical Average Gain
-80 °C
TPMOB0198EA
CATHODE
RADIANT
SENSITIVITY
107
106
101
100
QUANTUM
EFFICIENCY
10-1
10-2
TPMHB0179EA
R3809U-69
R3809U-68
10-3
800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
WAVELENGTH (nm)
CURRENT GAIN
CATHODE RADIANT SENSITIVITY (mA/W)
QUANTUM EFFICIENCY (%)
102
105
104
103
102
-2.0
-2.2
-2.4
-2.6
-2.8
-3.0
-3.2
-3.4
SUPPLY VOLTAGE (kV)
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K.
NIR MCP-PMT R3809U-68/-69 WITH C10221
SPECIFICATIONS
●R3809U-68/-69
GENERAL
Parameter
Spectral Response
Photocathode Material
Window Material
Effective Area of PMT
Stage of MCP B
Operating Ambient Temperature
Storage Temperature
R3809U-68
950 to 1400
InP / InGaAsP
R3809U-69
950 to 1700
InP / InGaAs
Unit
nm
—
—
mm
—
°C
°C
R3809U-69
Unit
V
nA
Borosilicate Glass
2
2
-90 to -70
-90 to +50
MAXIMUM RATING
Parameter
PMT Supply Voltage
Average PMT Anode Current
R3809U-68
-3400
50
CHARACTERISTICS (at -3000 V, -80 °C)
Parameter
Cathode Sensitivity C
Quantum Efficiency
Radiant
Gain
Anode Dark Count D
Voltage Driver Current
Time Response
Rise Time E
Fall Time F
Transit Time Spread A
Min.
0.1
1.0
1 × 105
—
—
—
—
—
R3809U-68
Typ.
1.0
5.2
2 × 105
2 × 104
—
170
450
70
Max.
—
—
—
1 × 105
100
—
—
100
Min.
0.1
1.2
1 × 105
—
—
—
—
—
R3809U-69
Typ.
1.0
6.1
2 × 105
5 × 104
—
170
450
70
Max.
—
—
—
5 × 105
100
—
—
100
Unit
%
mA/W
—
s-1
µA
ps
ps
ps
A Transit-time spread (TTS) is the fluctuation in transit time between individual pulse and specified as an FWHM (full width at half maximum) with the
incident light having a single photoelectron state.
B Two microchannel plates (MCP) are incorporated as a standard but we can provide it with either one or three MCPs as an option depending upon your request.
C At 1300 nm (R3809U-68), at 1500 nm (R3809U-69)
D At 30 minutes after high voltage is applied with shutter closed
E This is the mean time difference between the 10 % and 90 % amplitude points on the output waveform for full cathode illumination.
F This is the mean time difference between the 90 % and 10 % amplitude points on the tailing edge of the output waveform for full cathode illumination.
G IRF stands for Instrument Response Function which is a convolution of the δ pulse function (H(t)) of the measuring system and the excitation function (E(t)) of a laser. The IRF is given by the following formula:
IRF = H(t) × E(t)
We specify the IRF as an FWHM of the time distribution taken by using the measuring system in Figure 6 that is Hamamatsu standard IRF measurement. It can
be temporary estimated by the following equation:
(IRF (FWHM))2 = (TTS)2 + (Tw)2 + (Tj)2
where Tw is the pulse width of the laser used and Tj is the time jitter of all equipments used. An IRF data is provided with the tube purchased as a standard.
CAUTION: R3809U-68/-69 must be operated with C10221
●C10221 (EXCLUSIVE COOLER)
GENERAL
Parameter
Coolant Medium
Temperature Controllable Range
Cool-down Time
Liquid Nitrogen Consumption
Gas Pressure
Dry Nitrogen
Consumption
-HV Connector
Socket Assembly Signal Connector
Load Resistor
Power Consumption
Operating Ambient Temperature
Cooling Chamber
Weight
Controller, etc.
System Configuration
NOTE: PMT is not included in C10221
Description / Value
Liquid Nitrogen (LN2)
0 to -100 (continuously adjustable)
About 2 (-80 °C setting)
Approx. 0.75 (-100 °C setting)
35
47 L (14.7 MPa) / 10 h
SHV-R
SMA-R
Open
15
Less than +30
Approx. 6
Approx. 11
Chamber, Controller, Conductor Cable, Controller Solenoid,
Rubber Tube, Insulated Transfer Hose, LN2 Transfer Head
Unit
—
°C
h
L/h
kPa
—
—
—
—
VA
°C
kg
kg
—
Figure 3: Typical Output Waveform
Figure 4: Block Diagram of Output Waveform Measuring System
TPMHB0747EA
ND FILTER
TRIGGER
OUT
PICOSECOND
LIGHT
PULSER
R3809U-68/-69
WITH C10221
HAMAMATSU C4840
20 (mV/div)
HAMAMATSU
MODEL#PLP-01
WAVELENGTH: 410 nm
PULSE WIDTH
(FWHM)
: 35 ps
HIGH VOLTAGE
POWER SUPPLY
TEKTRONIX
11802
TRIGGER IN
SUPPLY VOLTAGE : -3000 V
RISE TIME
: 185 ps
FALL TIME
: 535 ps
WIDTH
: 330 ps
DIGITAL
50 Ω LOAD
SAMPLING
OSCILLOSCOPE
COMPUTER
0.2 (ns/div)
TPMHC0230EB
Figure 5: Typical Instrument Response Function (IRF) G
Figure 6: Block Diagram of IRF Measuring System
TPMHB0748EA
FWHM: 79 ps
RELATIVE COUNTS
104
103
ND FILTER
HAMAMATSU
PICOSECOND
MODEL#PLP-01
WAVELENGTH: 410 nm LIGHT
PULSER
PULSE WIDTH
(FWHM)
: 35 ps
TRIGGER
OUT
R3809U-68/-69
WITH C10221
HAMAMATSU C4840
HIGH VOLTAGE
POWER SUPPLY
102
HAMAMATSU
C5594
101
AMP
ORTEC 457
DELAY
100
START
TAC
ORTEC 425A
STOP
CFD
TENNELEC TC-454
MCA
COMPUTER
NAIG
TIME (0.2 ns/Div.)
TPMHC0231EB
NIR MCP-PMT R3809U-68/-69 WITH C10221
Figure 7: Dimensional Outlines (Unit: mm)
●R3809U-68/-69
ALUMINUM HOUSING CASE
13.7±0.1
SHV-R CONNECTOR
(-HV INPUT)
4.0±0.3
WINDOW THICKNESS
45.0±0.1
EFFECTIVE
PHOTOCATHODE
AREA: 2 MIN.
3.0±0.2
7.0±0.2
54.5±0.1
17.7±0.2
SMA-R CONNECTOR
(ANODE OUTPUT)
72.2±0.3
TPMHA0516EA
●C10221
• COOLING UNIT
• CONTROLLER
PHOTOCATHODE
6-M3
COOLER CHAMBER
HOLDER
APERTURE
120
60
°
60
°
293
98
111
10.0±0.1
222
DIGITAL DISPLAY & CONTROL
111
MCP-PMT
64.6±1.0
222
12
257
38
240
240
262
317
TACCA0278EA
Figure 8: System Configuration
■OTHER ACCESSORIES REQUIRED
●Liquid nitrogen dewar
Non-pressurized dewar having a capacity of 10 to 50 litters, and the neck outer diameter between 35 and 40 mm.
●High voltage power supply for the photomultiplier
tube (negative high voltage)
Output voltage: more than -3400 V
Output current: more than 0.2 mA
Low ripple, High stability
●Dry nitrogen gas, pressure regulator (secondary pressure 35 kPa), pressure gauge
In order to supply a proper amount of liquid nitrogen to
the cooling unit, an external pressure needs to be added
to the dewar. A pressure regulator capable of reducing a
secondary pressure to 35 kPa is necessary when used
with a dry nitrogen gas container. Connect the 3/8" rubber
tube to the exit of the pressure regulator.
*PRESSURE
REGULATOR
COOLING CHAMBER
SOLENOID
CONTROL
CABLE
HEATER CABLE
CONTROL CABLE
CONTROLLER
AC 100 V to 120 V,
AC 200 V to 240 V
INSULATED
TRANSFER
HOSE
3/8" OD
RUBBER TUBE
SOLENOID VALVE
LN2 TRANSFER HEAD
*DRY NITROGEN
GAS SOURCE
*DEWAR OF LN2
*NOT SUPPLIED.
ALL OTHERS ARE INCLUDED IN C10221.
TACCC0090ED
WEB SITE www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: [email protected]
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected]
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: [email protected]
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: [email protected]
TPMH1293E03
Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: [email protected]
AUG. 2007 IP