HY R2500

R1200/R1200F SERIES
REVERSE VOLTAGE - 1200 to 5000 Volts
FORWARD CURRENT - 0.2 /0.5Amperes
HIGH VOLTAGE RECTIGIERS
DO- 41
FEATURES
DO-15
● High voltage
● High current capability
● Low leakage current
● High surge capability
.034(0.9)
DIA
.028(0.7)
1.0(25.4)
MIN.
● Low cost
1.0(25.4)
MIN.
.034(0.9)
.028(0.7)
DIA
.300(7.6)
.230(5.8)
.205(5.2)
MAX
MECHANICAL DATA
.140(3.6)
.104(2.6) DIA.
.107(2.7)
DIA
.080(2.0)
●Case: Molded plastic use UL-94-O regognized
Flame Retardant Epoxy
1.0(25.4)
MIN
1.0(25.4)
MIN.
●Terminal: Axial leads solderable per
MIL-STD202,Method 208
●Polarity: Color band denotes cathode
●Mounting position: Any
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
CHARACTERISTICS
Maximum Peak Reverse Voltage
R1200
R1500
R1800
R2000
R2500
R1200F
R1500F
R1800F
R2000F
R2500F
1200
1500
1800
2000
2500
Maximum Average Rectified Current
@Half-Wave Resistive Load 60HZ TA =50 ℃
500
жR4000
R3000
жR5000
R3000F жR4000F жR5000F
3000
4000
200
5000
UNIT
Vpk
mA
Maximum Forward Peak Surge Current
@8.3ms Superimposed IFM(Surge)
30
Apk
Maximum Reverse Current
@ PRV@25℃ TA IR
5.0
uAdc
Maximum Forward Voltage
@ 25℃TA IF=0.5/0.2 Apk VFM
2
4.5
3
5
_
_
500
500
Vpk
Maximum Reverse Recovery Time ( Note 1)
ns
Operating and storage Temperature
-65 to +150
NOTES:1.Reverse recovery test conditions: IF=0.5A, IR=1A, Irr=0.25A
2.ж Package DO-15
~ 43 ~
℃
RATING AND CHARACTERISTIC CURVES
R1200/R1200F SERIES
FIG.1-REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
TRR
50Ω
10Ω
NONINDUCTIVE NONINDUCTIVE
+0.5A
(-)
(+)
D.U.T
25 VDC
(APPROX)
1Ω
NONINDUCTIVE
(-)
0
PULSE
GENERATOR
(NOTE 2)
-0.25A
(+)
OSCILLOSCOPE
(NOTE 1)
NOTES: 1. Rise Time=7ns max,Input impedance=
1 megohm,22pF
2. Rise Time=10ns max,Source Impedance=
50 oh ms.
-1.0A
1CM
FLG.3 –TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
FIG. 2 – FORWARD CURRENT DERATING CURVE
R1200-2000F
R1200-5000
R2500-5000
10
INSTANTANEOUS FORWARD CURRENT,
AMPERES
0.6
SINGLE PHASE
HALF WAVE
60HZ
RESISTIVE OR
INDUCTIVE LOAD
0.375”LEAD LENGTH
R1200-R2000
0.5
0.4
0.3
R2500-R5000
0.2
0.1
0
25
50
75
100
125
150
175
R2500-5000F
1.0
0.5
TJ = 25°C
0.1
0.01
AMBIENT TEMPERATURE (℃)
1.0
2.0
3.0
4.0
5.0
6.0
7.0
INSTANTANEOUS FORWARD VOLTAGE.VOLTS
FIG.4-PEAK FORWARD SURGE CURRENT
FORWARD SURGE CURRENT,AMPERES pk
(HALF-SINE WAVE)
AVERAGE FORWARD RECTIFIED CURRENT,
AMPERES
SET TIME BASE
FOR 50/1000ns/cm
50
40
30
20
10
0
1
2
4
10
20
NUMBER OF CYCLES AT 60Hz
~ 44 ~
40
100