ETC AL103

AL103
Revision 1.0
8 PORT LOW COST 10/100 SWITCH
•
•
•
•
•
•
•
•
•
•
•
Supports 8 10/100 Mbit/s MII ports
Capable of trunking up to 800 Mbit/s link
Trunk fail-over feature
Full- and half-duplex mode operation
Speed auto-negotiation through MDIO
Built-in storage of 1K MAC addresses
Design to utilize low-cost SGRAM
Serial EEPROM interface for low-cost
system configuration
Automatic source address learning
Secure mode traffic filtering
Broadcast storm control
•
•
•
•
•
•
•
•
Port monitoring support
IEEE 802.3x flow control for full-duplex
operation
Optional backpressure flow control support for half-duplex operation
Supports store-and-forward mode
switching
VLAN support
AL102A pin compatible
3.3V operation
Packaged in 256-pin PQFP
Product Description
The AL103 is an eight-port 10/100 Mbit/s dual speed Ethernet switch. A low-cost Fast Ethernet
switch can be implemented using the AL103 with low-cost SGRAM. The AL103 also supports
VLAN and multiple port aggregation trunks.
10/100 MAC
Switch
Controller
Buffer
Manager
10/100 MAC
10/100 MAC
High Speed
Switch Fabric
10/100 MAC
10/100 MAC
Address
Control
Address
Table
10/100 MAC
EEPROM
Interface
10/100 MAC
10/100 MAC
Figure 1
System Block Diagram
Reference Only / Allayer Communications
AL103 Revision 1.0
This document contains proprietary information which shall not be reproduced, transferred
to other documents, or used for any other purpose without the prior written consent of Allayer
Communications.
Disclaimer
Allayer Communications reserves the right to make changes, without notice, in the
product(s) described or information contained herein in order to improve the design and/or
performance. Allayer Communications assumes no responsibility or liability for the use of any
of these products, conveys no license or title under any patent or copyright to these products, and
makes no representations or warranties that these products are free from patent or copyright
infringement unless otherwise specified.
Life Support Applications
Allayer Communications products are not designed for use in life support appliances, systems,
or devices where malfunctions can be reasonably expected to result in personal injury.
9/00
Reference Only / Allayer Communications
2
Table of Contents
1.
AL103 Overview ..................................................................................................... 5
2.
Pin Descriptions....................................................................................................... 7
3.
Functional Description........................................................................................... 16
3.1
Data Reception............................................................................................... 16
3.1.1
Illegal Frame Length.............................................................................. 16
3.1.2
Long Frames .......................................................................................... 16
3.1.3
False Carrier Events ............................................................................... 16
3.1.4
Frame Filtering....................................................................................... 16
3.2
Frame Forwarding.......................................................................................... 17
3.2.1
Broadcast Storm Control........................................................................ 17
3.2.2
Frame Transmission............................................................................... 18
3.2.3
Frame Generation................................................................................... 18
3.3
Half Duplex Mode Operation ........................................................................ 18
3.4
Secure Mode Operation ................................................................................. 18
3.5
Address Learning ........................................................................................... 19
3.5.1
Address Aging........................................................................................ 19
3.6
VLAN Support............................................................................................... 19
3.7
Port Aggregation (Trunking).......................................................................... 21
3.7.1
Load Balancing ...................................................................................... 21
3.7.2
Trunk Fail Over...................................................................................... 21
3.7.3
Trunk Port Assignment .......................................................................... 22
3.7.4
Port Based Trunk Load Balancing ......................................................... 22
3.7.5
MAC Based Load Balancing ................................................................. 24
3.8
Flow Control .................................................................................................. 25
3.8.1
Half Duplex Flow Control (Backpressure) ............................................ 25
3.8.2
Full Duplex Flow Control (802.3x) ....................................................... 26
3.9
Queue Management ....................................................................................... 26
3.10
Uplink Port..................................................................................................... 27
3.11
Port Monitoring.............................................................................................. 27
3.12
Media Independent Interface (MII) ............................................................... 28
3.13
PHY Management.......................................................................................... 28
3.13.1
PHY Management MDIO ...................................................................... 28
Reference Only / Allayer Communications
AL103 Revision 1.0
3.13.2
PHY Management Master Mode ........................................................... 28
3.13.3
PHY Management Slave Mode.............................................................. 28
3.13.4
Non Auto-negotiation Mode .................................................................. 29
3.13.5
Other PHY Options................................................................................ 29
3.14
3.14.1
System Initialization .............................................................................. 29
3.14.2
Start and Stop Bit ................................................................................... 30
3.14.3
Write Cycle Operation ........................................................................... 30
3.14.4
Read Cycle Operation ............................................................................ 31
3.14.5
Reprogramming the EEPROM Configuration....................................... 31
3.14.6
EEPROM Map ....................................................................................... 32
3.15
9/00
EEPROM Interface ........................................................................................ 29
SGRAM Interface .......................................................................................... 36
4.
Register Description .............................................................................................. 36
5.
Timing Requirements............................................................................................. 51
6.
Electrical Specifications ........................................................................................ 59
7.
AL103 Mechanical Data........................................................................................ 60
8.
Appendix I (VLAN Mapping Worksheet) ............................................................. 61
9.
Appendix II (Port to Trunk Port Assignment Work Sheet) ................................... 62
10.
Appendix III (Suggested Memory Components)................................................... 63
Reference Only / Allayer Communications
4
AL103 Revision 1.0
1. AL103 Overview
The AL103 provides eight 10/100 Mbit/s Ethernet ports. Each port supports both 10 and 100
Mbit/s data rate. The operation mode is auto-negotiated by the PHY. All ports are full-duplex
capable. The device also supports VLAN for workgroup and segment switching applications.
The AL103 also supports trunking applications. The chip provides two optional load-balancing
schemes, explicit and dynamic. With trunking, it is possible to group up to four full-duplex links
together to form a single 800 Mbit/s link.
Data received from the MAC interface is stored in the external memory buffer. The AL103 utilizes
cost effective SGRAM to provide 8-Mbit or 16-Mbit of buffer memory.
During transmission, the data is obtained from the buffer memory and routed to the destination
port’s output buffer. If a collision occurs in half-duplex operation, the MAC control will back off
and retransmit in accordance to the IEEE 802.3 specification.
The AL103 provides two flow control methods. For half-duplex operations, an optional jamming
based flow control (known as backpressure) is available to prevent loss of data. With this method of
flow control, the switch will generate a jam signal when the receive buffer is full and the sending
station will not start to transmit until the line is clear. In the full-duplex mode, the AL103 utilizes
IEEE 802.3x as the flow control mechanism.
All ports support multiple MAC addresses. The switch chip supports 1K MAC addresses internally.
These MAC addresses are shared among all eight ports.
The initialization and configuration of the switch is programmed by an external EEPROM. Field
reconfiguration can be achieved by using a parallel interface to reprogram the EEPROM.
The AL103 also supports port based VLAN. The VLAN register set is used to configure the
destination ports for multicast and broadcast frames.
The device also provides two levels of security for intrusion protection. Security can be
implemented on a per port basis.
The AL103 operates only in the store and forward mode. The entire frame is checked for error and
any frames with errors are automatically filtered and will not be forwarded to the destination port.
The AL103 also features port monitoring and broadcast storm throttling.
9/00
Reference Only / Allayer Communications
5
AL103 Revision 1.0
NC
PBANC_8
NC
EECLK
EEDIO
PBCS#
PBCAS#
PBWE#
GND
SYSCLK
Vcc
PBRAS#
PBA9_10
PBA0
PBA1
PBA2
PBA3
Vcc
PBA4
PBA5
PBA6
PBA7
PBA8_9
PBD0
GND
PBD1
PBD2
PBD3
PBD4
PBD5
PBD6
PBD7
Vcc
PBD16
PBD17
PBD18
PBD19
PBD20
PBD21
GND
PBD22
PBD23
PBD8
PBD9
PBD10
PBD11
PBD12
PBD13
GND
PBD14
PBD15
GND
PBD24
PBD25
Vcc
PBD26
PBD27
PBD28
PBD29
PBD30
PBD31
PBCLKI
NC
NC
Pin Diagram
193
195
200
205
210
215
220
225
230
235
240
NC
NC
M0CRS
GND
M0COL
GND
M0TXD3
M0TXD2
M0TXD1
Vcc
M0TXD0
M0TXEN
M0TXCLK
M0RXER
M0RXCLK
M0RXDV
M0RXD0
M0RXD1
M0RXD2
GND
M0RXD3
GND
GND
GND
M1CRS
Vcc
M1COL
Vcc
M1TXD3
M1TXD2
M1TXD1
Vcc
M1TXD0
M1TXEN
M1TXCLK
M1RXER
M1RXCLK
M1RXDV
M1RXD0
M1RXD1
M1RXD2
GND
M1RXD3
GND
Vcc
M2CRS
GND
M2COL
GND
M2TXD3
M2TXD2
M2TXD1
Vcc
M2TXD0
M2TXEN
M2TXCLK
M2RXER
M2RXCLK
M2RXDV
M2RXD0
M2RXD1
NC
NC
NC
245
250
1
190
5
Pin 1 I.D.
185
10
180
15
175
20
170
25
165
30
160
35
155
40
150
45
145
50
140
55
135
125
120
115
110
105
100
95
90
85
80
75
70
60
130
NC
NC
Vcc
GND
M7RXD3
GND
M7RXD2
M7RXD1
M7RXD0
M7RXDV
M7RXCLK
M7RXER
M7TXCLK
M7TXEN
M7TXD0
Vcc
M7TXD1
M7TXD2
M7TXD3
Vcc
M7COL
Vcc
M7CRS
Vcc
GND
GND
M6RXD3
GND
M6RXD2
M6RXD1
M6RXD0
M6RXDV
M6RXCLK
M6RXER
M6TXCLK
M6TXEN
M6TXD0
Vcc
M6TXD1
M6TXD2
M6TXD3
Vcc
M6COL
Vcc
M6CRS
Vcc
GND
M5RXD3
GND
M5RXD2
M5RXD1
M5RXD0
M5RXDV
M5RXCLK
M5RXER
M5TXCLK
M5TXEN
M5TXD0
VccM
M5TXD1
M5TXD2
M5TXD3
NC
NC
129
Figure 2
9/00
Vcc
M4TXD0
M4TXEN
M4TXCLK
M4RXER
M4RXCLK
M4RXDV
M4RXD0
M4RXD1
M4RXD2
GND
M4RXD3
GND
Vcc
GND
M5CRS
Vcc
M5COL
Vcc
NC
NC
NC
NC
M2RXD2
GND
M2RXD3
GND
Vcc
Vcc
M3CRS
GND
M3COL
GND
M3TXD3
M3TXD2
M3TXD1
GND
M3TXD0
M3TXEN
M3TXCLK
M3RXER
M3RXCLK
M3RXDV
M3RXD0
M3RXD1
M3RXD2
Vcc
M3RXD3
Vcc
MDC
MDIO
DEVID0
DEVID1
RESET#
TESTMODE
EPBYPASS
GND
M4CRS
GND
M4COL
GND
M4TXD3
M4TXD2
M4TXD1
65
AL103 Pin Diagram (Top View)
Reference Only / Allayer Communications
6
AL103 Revision 1.0
2. Pin Descriptions
Table 1: MII Interface Port 0
PIN
NAME
PIN
NUMBER
M0TXD3
M0TXD2
M0TXD1
M0TXD0
7
8
9
11
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M0TXEN
12
O
Transmit Enable.
Synchronous to the transmit clock.
M0TXCLK
13
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M0RXD3
M0RXD2
M0RXD1
M0RXD0
21
19
18
17
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M0RXDV
16
I
Receive Data Valid.
M0RXCLK
15
I
Receive Clock.
M0RXER
14
I
Receive Data Error.
M0CRS
3
I
Carrier Sense.
M0COL
5
I
Collision Detect.
I/O
DESCRIPTION
Table 2: MII Interface Port 1
9/00
PIN
NAME
PIN
NUMBER
M1TXD3
M1TXD2
M1TXD1
M1TXD0
29
30
31
33
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M1TXEN
34
O
Transmit Enable.
Synchronous to the transmit clock.
M1TXCLK
35
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
I/O
DESCRIPTION
Reference Only / Allayer Communications
7
AL103 Revision 1.0
Table 2: MII Interface Port 1 (Continued)
M1RXD3
M1RXD2
M1RXD1
M1RXD0
43
41
40
39
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M1RXDV
38
I
Receive Data Valid.
M1RXCLK
37
I
Receive Clock.
M1RXER
36
I
Receive Data Error.
M1CRS
25
I
Carrier Sense.
M1COL
27
I
Collision Detect.
Table 3: MII Interface Port 2
9/00
PIN
NAME
PIN
NUMBER
M2TXD3
M2TXD2
M2TXD1
M2TXD0
50
51
52
54
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M2TXEN
55
O
Transmit Enable.
Synchronous to the transmit clock.
M2TXCLK
56
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M2RXD3
M2RXD2
M2RXD1
M2RXD0
69
67
61
60
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M2RXDV
59
I
Receive Data Valid.
M2RXCLK
58
I
Receive Clock.
M2RXER
57
I
Receive Data Error.
M2CRS
46
I
Carrier Sense.
M2COL
48
I
Collision Detect.
I/O
DESCRIPTION
Reference Only / Allayer Communications
8
AL103 Revision 1.0
Table 4: MII Interface Port 3
PIN
NAME
PIN
NUMBER
M3TXD3
M3TXD2
M3TXD1
M3TXD0
77
78
79
81
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M3TXEN
82
O
Transmit Enable.
Synchronous to the transmit clock.
M3TXCLK
83
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M3RXD3
M3RXD2
M3RXD1
M3RXD0
91
89
88
87
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M3RXDV
86
I
Receive Data Valid.
M3RXCLK
85
I
Receive Clock.
M3RXER
84
I
Receive Data Error.
M3CRS
73
I
Carrier Sense.
M3COL
75
I
Collision Detect.
I/O
DESCRIPTION
Table 5: MII Interface Port 4
9/00
PIN
NAME
PIN
NUMBER
M4TXD3
M4TXD2
M4TXD1
M4TXD0
105
106
107
109
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M4TXEN
110
O
Transmit Enable.
Synchronous to the transmit clock.
M4TXCLK
111
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M4RXD3
M4RXD2
M4RXD1
M4RXD0
119
117
116
115
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M4RXDV
114
I
Receive Data Valid.
I/O
DESCRIPTION
Reference Only / Allayer Communications
9
AL103 Revision 1.0
Table 5: MII Interface Port 4 (Continued)
M4RXCLK
113
I
Receive Clock.
M4RXER
112
I
Receive Data Error.
M4CRS
101
I
Carrier Sense.
M4COL
103
I
Collision Detect.
Table 6: MII Interface Port 5
PIN
NAME
PIN
NUMBER
M5TXD3
M5TXD2
M5TXD1
M5TXD0
131
132
133
135
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M5TXEN
136
O
Transmit Enable.
Synchronous to the transmit clock.
M5TXCLK
137
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M5RXD3
M5RXD2
M5RXD1
M5RXD0
145
143
142
141
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M5RXDV
140
I
Receive Data Valid.
M5RXCLK
139
I
Receive Clock.
M5RXER
138
I
Receive Data Error.
M5CRS
123
I
Carrier Sense.
M5COL
125
I
Collision Detect.
I/O
DESCRIPTION
Table 7: MII Interface Port 6
9/00
PIN
NAME
PIN
NUMBER
M6TXD3
M6TXD2
M6TXD1
M6TXD0
152
153
154
156
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M6TXEN
157
O
Transmit Enable.
Synchronous to the transmit clock.
I/O
DESCRIPTION
Reference Only / Allayer Communications
10
AL103 Revision 1.0
Table 7: MII Interface Port 6 (Continued)
M6TXCLK
158
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M6RXD3
M6RXD2
M6RXD1
M6RXD0
166
164
163
162
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M6RXDV
161
I
Receive Data Valid.
M6RXCLK
160
I
Receive Clock.
M6RXER
159
I
Receive Data Error.
M6CRS
148
I
Carrier Sense.
M6COL
150
I
Collision Detect.
Table 8: MII Interface Port 7
9/00
PIN
NAME
PIN
NUMBER
M7TXD3
M7TXD2
M7TXD1
M7TXD0
174
175
176
178
O
Transmit Data - NRZ data to be transmitted to transceiver.
Signal TX_EN and TXD0 through TX_D3 are clocked out by
the rising edge of TX_CLK.
M7TXEN
179
O
Transmit Enable.
Synchronous to the transmit clock.
M7TXCLK
180
I
Transmit Clock Input.
25 MHz for 100 Mbit/s and 2.5 MHz for 10 Mbit/s.
M7RXD3
M7RXD2
M7RXD1
M7RXD0
188
186
185
184
I
Receive Data - NRZ data from the transceiver.
For MII interface, signal RX_DV, RX_ER and RX_D0 through
RX_D3 are sampled by the rising edge of RX_CLK.
M7RXDV
183
I
Receive Data Valid.
M7RXCLK
182
I
Receive Clock.
M7RXER
181
I
Receive Data Error.
M7CRS
170
I
Carrier Sense.
M7COL
172
I
Collision Detect.
I/O
DESCRIPTION
Reference Only / Allayer Communications
11
AL103 Revision 1.0
Table 9: SGRAM Interface
9/00
PIN
NAME
PIN
NUMBER
PBD31
PBD30
PBD29
PBD28
PBD27
PBD26
PBD25
PBD24
PBD23
PBD22
PBD21
PBD20
PBD19
PBD18
PBD17
PBD16
PBD15
PBD14
PBD13
PBD12
PBD11
PBD10
PBD9
PBD8
PBD7
PBD6
PBD5
PBD4
PBD3
PBD2
PBD1
PBD0
196
197
198
199
200
201
203
204
215
216
218
219
220
221
222
223
206
207
209
210
211
212
213
214
225
226
227
228
229
230
231
233
PBA9_10
I/O
DESCRIPTION
I/O
SGRAM Data Bus.
244
O
SGRAM Address. For 16 Mbit/s SGRAM, this pin is PBA10 and
for 8 Mbit/s SGRAM this pin is PBA 9.
PBA8_9
234
O
SGRAM Address. For 16 Mbit/s SGRAM, this pin is PBA9 and
for 8 Mbit/s SGRAM this pin is PBA 8.
PBANC_8
255
O
SGRAM Address. For 16 Mbit/s SGRAM, this pin is PBA8 and
for 8 Mbit/s SGRAM when this pin is not connected.
Reference Only / Allayer Communications
12
AL103 Revision 1.0
Table 9: SGRAM Interface (Continued)
PBA7
PBA6
PBA5
PBA4
PBA3
PBA2
PBA1
PBA0
235
236
237
238
240
241
242
243
O
SGRAM address line PBA0- PBA8 are sampled during the
ACTIVE command (row address) and READ/WRITE command
(column address with PBA8 defining auto precharge).
PBCS#
251
O
Chip Select. Enables and disables the command decoder of
the SGRAM.
PBRAS#
245
O
SGRAM Row Address Strobe.
PBCAS#
250
O
SGRAM Column Address Strobe.
PBWE#
249
O
Write Enable.
PBCLKI
195
O
System Clock Output to Drive the SGRAM.
Table 10: EEPROM Interface
PIN
NAME
PIN
NUMBER
I/O
DESCRIPTION
EEDIO
252
I/O
EEPROM Serial Data Input and Output.
EECLK
253
O
EEPROM Serial Clock.
Table 11: MII PHY Management Interface
9/00
PIN
NAME
PIN
NUMBER
I/O
MDC
93
O
PHY Management Clock.
MDIO
94
I/O
PHY Management Data Input and Output.
DESCRIPTION
Reference Only / Allayer Communications
13
AL103 Revision 1.0
Table 12: Miscellaneous Pins
PIN NAME
PIN NUMBER
I/O
DESCRIPTION
DEVID0
DEVID1
95
96
I
Device ID Number. For AL103,
both pins should be connected to
ground.
RESET#
97
I
Reset
TESTMODE
98
I
Test Mode Pin. This pin should be
grounded for normal operation.
EPBYPASS
99
I
This pin bypasses the EEPROM
setup. This pin should be tied to
ground.
SYSCLK
247
I
80 MHz System Clock.
NC
1, 2, 62, 63, 64, 65, 66, 127, 128,
129, 130, 191, 192, 193, 194, 254,
256
--
No Connect.
Table 13: Power Interface
9/00
PIN NAME
PIN NUMBER
DESCRIPTION
GND
4, 6, 20, 22, 23, 24, 42, 44, 47, 49, 68, 70,
74, 76, 80, 100, 102, 104, 118, 120, 122,
144, 146, 165, 167, 168, 187, 189, 205,
208, 217, 232, 248
Ground
Vcc (3.3V)
10, 26, 28, 32, 45, 53, 71, 72, 90, 92, 108,
121, 124, 126, 147, 149, 151, 155, 169,
171, 173, 177, 190, 202, 224, 239, 246
3.3V Supply Voltage.
VccM
134
Supply Voltage for MII Interface.
VccM = 5V (5V MII interface)
VccM = 3.3V (3.3V MII interface)
Reference Only / Allayer Communications
14
AL103 Revision 1.0
MXTXD3
MXTXD2
MXTXD1
MXTXD0
MXTXEN
MXTXCLK
MXRXD3
MXRXD2
MXRXD1
MXRXD0
MXRXDV
MXRXCLK
MXRXER
MXCRS
MXCOL
32
PBD[n]
9
PBA[n]
PBBA
PBCS
PBRAS
PBCAS
PBWE
PBDSF
PBDQM
PBCLK
10/100 MAC
Switch
Controller
10/100 MAC
10/100 MAC
10/100 MAC
10/100 MAC
10/100 MAC
High Speed
Switch Fabric
Address
Control
10/100 MAC
10/100 MAC
Address
Table
Buffer
Manager
PHY
Management
MDIO
MDC
Management
Information
EEPROM
Interface
EEDIO
EECLK
RESET
Figure 3
9/00
AL103 Interface Block Diagram
Reference Only / Allayer Communications
15
AL103 Revision 1.0
3. Functional Description
3.1 Data Reception
The port will go into the receive-state when RX_DV in the MII interface is asserted. The MII
(Media Independent Interface) presents the received data in four-bit nibbles that are synchronous to
the receive clock (25 MHz for 100 Mbit/s or 2.5 MHz for 10 Mbit/s). The AL103 will then attempt
to detect the occurrence of the SFD (Start Frame Delimiter) pattern “10101011.” All preamble data
prior to SFD are discarded. Once SFD is detected from the MII interface, the frame data is
forwarded and stored in the buffer of the switch.
3.1.1 Illegal Frame Length
During the receiving process, the AL103 MAC will monitor the length of the received frame. Legal
Ethernet frames should have a length of no less than 64 bytes and no more than 1536 bytes. Any
frames with illegal frame length are discarded.
3.1.2 Long Frames
The AL103 can handle frame size up to 1536 bytes. All frames longer than 1536 bytes will be
discarded. If the port continues to receive data after the 1536th byte, the port’s data will be filtered.
If the port is in half-duplex mode, the port will no longer be able to transmit or receive data during
the long frame reception.
3.1.3 False Carrier Events
If CRS (Carrier Sense) signal in the MII interface is asserted but the receive RX_DV (Receive Data
Valid) signal is not asserted within 16BT (Bit Period), the port is considered to have a false carrier
event.
3.1.4 Frame Filtering
The AL103 will make filtering and forwarding decisions for each frame received based on its frame
routing table, VLAN Mapping, port state, and the system configuration.
Under the following conditions, received frames are filtered:
9/00
•
The AL103 will check all received frames for errors such as symbol error, FCS
error, short event, runt, long event, etc. Frames with any kind of error will not be
forwarded to their destination port.
•
Any frame heading to its own source port will be filtered.
•
Frames heading to a disabled receiving port will be filtered.
•
If the input buffer of the port is full, the incoming frame will be discarded. It is
recommended that the flow control be used to prevent any loss of data. If the flow
control option is enabled, this event will not occur. The remote station will
transmit frame when the input buffer becomes available.
•
If the frame has any security violation and the security option is enabled at the
receiving port.
Reference Only / Allayer Communications
16
AL103 Revision 1.0
3.2 Frame Forwarding
After a frame is received, both source address (SA) and destination address (DA) are retrieved. The
SA is used to update the port’s address table and the DA is used to determine the frames destination
port.
The Address Lookup Engine will attempt to match the destination address with the addresses stored
in the address table. If there is a match found, a link between the source port and the destination
port is then established.
If the first bit of the destination address is “0,” the frame is regarded as an unicast frame. The
destination address is passed to the Address Lookup Engine, which returns a matched destination
port number to identify which port the frame should be forwarded to. If the destination port is
within the same VLAN of the receiving port, the frame will be forwarded. If the destination port
does not belong to the VLANs specified at the receiving ports, the frame will be discarded. The
event will be recorded as a VLAN boundary violation.
There are two ways that the AL103 handles frames with unknown destinations. The forwarding
decision is controlled by the Flood Control option (System Configuration Register 00). If Flood
Control is disabled, the frame will be forwarded to all ports (except the receiving port) within the
same VLANs of the receiving port. If the Flood Control option is enabled, the AL103 will forward
the frame only to the uplink port specified at the receiving port.
Note: The AL103 defines a port as either a single port or a trunk.
If the port monitoring function is enabled, the frame forwarding decision is also subject to the port
monitoring configurations.
If the first bit of the destination address is a “1,” the frame will be handled as a multicast or
broadcast frame. The AL103 does not differentiate multicast frames from broadcast frames except
for the reserved bridge management group address, as specified in table 3.5 of IEEE 802.1d
standard. The destination ports of the broadcast frame are all ports within the same VLAN except
the source port itself.
3.2.1 Broadcast Storm Control
One of the unique features provided by the AL103 is Broadcast Storm Control. This option allows
the user to limit the number of broadcast frames into the switch. This option can be implemented on
a per port basis. A threshold number of broadcast frames can be programmed in System Register II
(register 01).
When Storm Control is enabled and the number of cumulated non-unicast frames is over the
programmed threshold, the broadcast frame is discarded.
If Storm Control is disabled, or the number of non-unicast frames received is not over the
programmed threshold, the AL103 will forward the frame to all ports (except the receiving port)
specified within the VLANs at the receiving port.
If Broadcast-Storm-drop (BConly_SC) is enabled in System Register III (register 02), the AL103
will only drop broadcast frames but not the multicast frames.
9/00
Reference Only / Allayer Communications
17
AL103 Revision 1.0
3.2.2 Frame Transmission
The AL103 transmits all frames in accordance to IEEE 802.3 standard. The AL103 will send the
frames with a guaranteed minimum IPG (Inter Packet/Frame Gap) of 96BT even if the received
frames have an IPG less than the minimum requirement. The AL103 also supports transmission of
frames with an IPG of 64BT (optional). This option can be selected in System Register III, Bit 8,
Register 02.
3.2.3 Frame Generation
During a transmit process the frame data is read from the memory buffer and forwarded to the
destination port’s PHY device in di-bits. Seven bytes of preamble signal (10101010) will be
generated first before the SFD (10101011). Frame data is sent after the SFD along with four-bytes
of FCS at the end.
3.3 Half Duplex Mode Operation
For half-duplex operation, the MAC logic will abort the transmit-process if collision is detected.
Re-transmission of the frame is scheduled in accordance to IEEE 802.3’s truncated binary
exponential back-off algorithm. If the transmit process has encountered 16 consecutive collisions,
an excessive collision error is reported and AL103 will not try to re-transmit the frame unless the
retry-on-excessive-collision (REC) option in System Register III (register 02) is enabled. When
REC is enabled, the number of collisions are reset to zero and transmission is started as soon as 96
bit time of inter packet gap is passed after the last collision. If a collision is detected after 512 BT of
the transmission, a late collision error will be reported but the frame will still be retransmitted after
proper back-off time.
The AL103 also provides an option for an aggressive back-off in the System Configuration Register
II (SuperMAC). This option allows the MAC to back-off only three slots. This will create a more
aggressive channel capture behavior than the standard IEEE back-off algorithm.
3.4 Secure Mode Operation
The AL103 provides security support on a per port basis. Whenever the secure mode is enabled, the
port will stop learning new addresses. The address table of each port will remain unchanged. In this
mode of operation, the address lookup table will freeze and no additional new address will be
learned.
The AL103 provides two levels of security protection. The most severe intrusion protection is
disabling a port if intrusion is experienced. The security management (SecMgmt bit in register 01)
will disable a port if a frame with unlearned source address (SA) is received from a secured port
(security violation). An alternative is to enable security at the local port level without the security
management. When the AL103 is configured this way, the device will only discard frames that have
security violations, which prevents intruders from accessing the network.
9/00
Reference Only / Allayer Communications
18
AL103 Revision 1.0
3.5 Address Learning
The Table Lookup Engine provides the switching information required to route data frames. The
address lookup table is set-up through auto address learning (dynamic) or manual entry (static). The
static addresses are assigned to the address table by the EEPROM. All static address entries will not
be aged or updated by the AL103.
After a frame is received by the AL103, the embedded (SA) and destination address (DA) are
retrieved. The source address retrieved from the received frame is automatically stored in a SA
buffer. The AL103 will then check for error and security violations, and perform a SA search. If
there is no error or security violation, the AL103 will store the source address in the address lookup
table. If the SA has been previously stored in another port’s SA table, the AL103 will delete the SA
from the previously stored location.
The Individual MAC Address is a 48-bit unique MAC address to be programmed or learned. Bit 0
of a SA will be masked, i.e. no multicast SA.
The AL103 provides an on-chip 1K MAC Address-to-PortID/TrunkID table for the frame
destination lookup operations.
The AL103 address table contains both static addresses input by the EEPROM and dynamically
learned address. It learns the individual MAC addresses from frame received with no errors from
the local ports.
For received frames that contain a source address learned in another port’s address table, that hasn’t
been aged out, perform the following based on the switches; if the security option is selected for the
port, the AL103 considers this a security violation; if port is a non-protected port, the AL103 will
delete the SA from the previous port’s address table and update it to the current port’s address table.
However, if the SA is a static address entry, the address will not be updated.
3.5.1 Address Aging
A port’s MAC address register is cleared on power-up, or hardware reset. If the SA aging option is
enabled, the dynamically learned SA will be cleared if it is not refreshed within the programmed
time.
3.6 VLAN Support
Each port of the AL103 can be assigned to one or multiple VLANs. Frames from the source port
will only be forwarded to destination ports within the same VLAN domain. A broadcast/multicast
frame will be forwarded to all ports within the VLAN(s) except the source port itself. A unicast
frame will be forwarded to the destination port only if the destination port is in the same VLAN as
the source port. Otherwise, the frame will be treated as a frame with unknown DA. If the
destination port belongs to the another VLAN, the frame will be discarded and the event will be
recorded as a VLAN boundary violation.
Each port can be assigned with a dedicated uplink port. Unicast frames with unknown destination
addresses will be forwarded to the uplink port of the source port. An uplink port can be either a
single port or a trunk.
The AL103 provides one VLAN register per ports (register 1E to 2C) for mapping to 8-ports (8bits). Each register contains an 8-bit map to indicate the VLAN group for the port.
9/00
Reference Only / Allayer Communications
19
AL103 Revision 1.0
The VLAN registers hold a broadcast destination mask for each source port. The value “1” will
indicate the broadcast frames will be routed from the source port to the specified port. Note that the
source port bit must be set to “0” within the source port VLAN, because broadcast frames are not
routed to the source port.
For setting up VLAN for trunking, please see the following section on trunking for detail.
VLAN Set Up Example
A VLAN set up worksheet is provided in Appendix I. You can complete the VLAN map easily by
simply marking the ports you wish to send broadcast frame to.
For example, let’s assume we want to set up two VLAN groups in an 8-port switch:
Group 1 consists of: 0, 1, 2, 5, and 6.
Group 2 consists of: 2, 3, 4, and 7.
The completed VLAN bit maps are shown in Table 14.
9/00
PORT
BIT
PORT 0/REG. 1E
PORT 1/REG. 20
PORT 2/REG. 22
PORT 3/REG. 24
PORT 4/REG. 26
PORT 5/REG. 28
PORT 6/REG. 2A
PORT 7/REG. 2C
Table 14: VLAN Map for an 8 Port Switch
7
7
0
0
1
1
1
0
0
0
6
6
1
1
1
0
0
1
0
0
5
5
1
1
1
0
0
0
1
0
4
4
0
0
1
1
0
0
0
1
3
3
0
0
1
0
1
0
0
1
2
2
1
1
0
1
1
1
1
1
1
1
1
0
1
0
0
1
1
0
0
0
0
1
1
0
0
1
1
0
Reference Only / Allayer Communications
20
AL103 Revision 1.0
3.7 Port Aggregation (Trunking)
The AL103 supports trunking/port aggregation. Port aggregation and trunking is essentially a
method to treat multiple physical links as a single logical link. The benefit of trunking is the ability
to group multiple lower speed links into one higher speed link. For example, four full-duplex 100
Mbps links can be used as one single 800-Mbps link. This is very useful for switch to switch,
switch to server, and switch to router applications.
The AL103 considers a trunk as a single port entity regardless of the trunk composition. Two to
four ports can be grouped together as a single trunk link. The grouping of the ports in the trunk
must be from the top four ports or the bottom four ports of the device, i.e. port 0 to 3 or port 4 to 7.
In a multiple link trunk, the links within the trunk should have a balanced amount of traffic in order
to achieve maximum efficiency. One of the requirements for transmission is that the frames being
transmitted must be in order. Therefore, some sort of load balancing among the links of the trunk
must be deployed. The AL103 offers two methods of load balancing which can be selected in the
System Configuration Register I (register 00).
3.7.1 Load Balancing
The two load-balancing methods that AL103 uses to support trunking are port based and MAC
address based. Port based load balancing method is an explicit port assignment scheme. It requires
each individual port be assigned to a specific link (trunk port) in the trunk. If the port is not
assigned, the frame might be routed to the trunk randomly which may cause the frames to go out of
order. The port based load balancing trunk can be assigned as a 2-, 3-, or 4-port trunk.
During transmission of the frame, it will be routed from the source port to the assigned trunk port.
When a frame is received from any one of the trunk ports, it will be routed to the destination port
within the VLAN. In essence, the AL103 treats a trunk as any single port within the same VLAN. If
the ports traffic is evenly distributed among all the trunk ports, load balancing is achieved and the
aggregate bandwidth of the trunk can be as high as 800 Mbit/s (full-duplex).
The alternative is the MAC address based load balancing. When the AL103 receives a frame with a
trunk destination, it will automatically forward the frame to a port in the trunk based on the source,
destination, or the combination of the source and destination MAC address. The MAC address load
balancing decision is based on a proprietary algorithm. The MAC address based load-balancing
trunk also can be assigned as a 2-, 3-, or 4-port trunk.
3.7.2 Trunk Fail Over
If a link is lost in one of the trunk ports, frame loss will occur. The trunk fail-over feature in the
AL103 can prevent frame loss caused by link failure in a trunk port. When the trunk fail-over option
is enabled in register 2D, bit 9 (L2Fail), the AL103 will automatically shift the load from the port
with the lost link to the next available port. This option is available for MAC address based loading
trunk only. Once the port with a lost link recovers and links up, the AL103 will return to the original
trunk setting.
9/00
Reference Only / Allayer Communications
21
AL103 Revision 1.0
3.7.3 Trunk Port Assignment
The maximum number of trunks for the AL103 is two. The Port Configuration I registers provide
the ability to designate a port to be a member of a trunk. The trunk can consist of up to four trunk
ports. A trunk group must consist of either the top four ports or the bottom four ports, for example a
trunk can consist of port 0 through port 3 or port 4 through port 7. Each trunk port’s number is in
sequence of 00, 01, 10, and 11 corresponding to the order of port of the devices. For example, port
1 and 5 are 01 (See Figure 4).
AL103
Ports
0
1
2
3
Trunk Port 0
Figure 4
4
5
6
7
Trunk Port 1
Trunk Port Numbering
3.7.4 Port Based Trunk Load Balancing
For port-based load balancing, a trunk port must be assigned to each port for all defined trunks. The
port assignment is done by programming Port to Trunk Port Registers (2E to 35). A port assignment
worksheet is provided at the back of the data sheet. It is recommended that ports be evenly
distributed among all trunk ports to prevent overloading any single trunk port.
Port Based Load Balancing Set up Example
Note: Register bits are reference by X.Y, where “X” is the register number and “Y” is the bit
number. Appendix I and II provide a worksheet for port to trunk port and VLAN assignment.
The example is designing an 8-port switch with a 3-port based loading trunk. The desired trunk
ports are 5, 6, and 7. We want to assign port 0 to trunk port 5, port 1 and 3 to trunk port 6, and port
2 and 4 to trunk port 7.
1. The Port Configuration I register bits 15.9, 16.9, and 17.9 are set to 1. This assigns
ports 5, 6, and 7 as a trunk port.
2. Assign port 0 to trunk port 5, port 1 and 3 to trunk port 6, and port 2 and 4 to trunk
port 7. Therefore, set port to trunk port register bits.
2E.2= 0, 2E.3 =1
2F.2= 1, 2F.3 =0
30.2= 1, 30.3 =1
31.2= 1, 31.3 =0
32.2= 1, 32.3 =1
9/00
Reference Only / Allayer Communications
22
AL103 Revision 1.0
3. Trunk ports should be assigned with their own port number in the port to trunk
Port register. The port to trunk-port bits are as follows:
33.2= 0, 33.3 =1
34.2= 1. 34.3 =0
35.2= 1, 35.3 =1
Set the remaining bits to all zeros in port to trunk port registers.
4. Assigning VLAN. The VLAN map should be assigned as shown.
All bits are set to “1” while the bits 1E.6 and 1E.7 are set to “0” because port 0 is assigned to port 5.
All the other ports are set up similarly. Bits 15 through 8 are reserved and should be set to ‘0’ for all
VLAN mapping registers.
9/00
PORT
BIT
PORT 0/REG. 1E
PORT 1/REG. 20
PORT 2/REG. 22
PORT 3/REG. 24
PORT 4/REG. 26
PORT 5/REG. 28
PORT 6/REG. 2A
PORT 7/REG. 2C
Table 15: VLAN Mapping for Port Based Load Balancing Trunk
7
7
0
0
1
0
1
0
0
0
6
6
0
1
0
1
0
0
0
0
5
5
1
0
0
0
0
0
0
0
4
4
1
1
1
1
0
1
1
1
3
3
1
1
1
0
1
1
1
1
2
2
1
1
0
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
0
0
0
1
1
1
1
1
1
1
Reference Only / Allayer Communications
23
AL103 Revision 1.0
3.7.5 MAC Based Load Balancing
For MAC address based load balancing, there is no need to assign a port to a trunk port. The AL103
dynamically assigns MAC addresses to the trunk port. MAC address based trunks can consist of
two, three, or four trunk ports. The bits are chosen for their randomness. The statistically random
bits will ensure good load balancing among all trunk-ports.
The following is a procedure to set up the MAC based load trunk.
1. Select MAC address load trunking by setting bit 00.3 to “1.”
2. Select the trunk ports using Port Configuration Register I bit 9.
3. Assign the ports and the trunk port to the same VLAN using register 1E to 2C.
4. When the number of trunk ports is four, the following steps are not required. If the
number of trunk ports are two or three, set register bit 2D.8 (L2MAP) to “1.”
5. Set the TrunkMap1 or TrunkMap0 in register bits 7 through 0. These bits indicate
the mapping of trunk ports. For example, if ports 0 and 1 are used as trunk ports,
then set the bits 2D.0 and 2D.1 to “1.” If ports 5 and 7 are used as trunk ports, set
bits 2D.5 and 2D.7. The trunk port mapping and the trunk member bits set in Port
Configuration I register must match.
6. Finally, select the algorithm for MAC based loading. Set register 2D.10 to “1” for
source address only, and “0” for the combination of source and destination
addresses.
The port VLAN grouping should include all the trunk ports. Since the AL103 will assign the port
by MAC addresses, frames from any single port may be routed to any trunk ports.
MAC Based Load Balancing Example
The desired trunk port is 4, 5, 6, and 7. Therefore, the port configuration register bits 15.9, 17.9,
19.9, and 1B.9 are set to “1.” Select MAC address loading by setting bit 00.3 to “1.”
9/00
Reference Only / Allayer Communications
24
AL103 Revision 1.0
PORT
BIT
PORT 0/REG. 1D
PORT 1/REG. 1F
PORT 2/REG. 21
PORT 3/REG. 23
PORT 4/REG. 25
PORT 5/REG. 27
PORT 6/REG. 29
PORT 7/REG. 2B
Table 16: VLAN Mapping for MAC Based Loading Trunk
7
7
1
1
1
1
0
0
0
0
6
6
1
1
1
1
0
0
0
0
5
5
1
1
1
1
0
0
0
0
4
4
1
1
1
1
0
0
0
0
3
3
1
1
1
0
1
1
1
1
2
2
1
1
0
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
0
0
0
1
1
1
1
1
1
1
Note: All bits are set to “1” except the ports themselves.
3.8 Flow Control
The AL103 can operate at two different modes, half- and full-duplex. Each port can operate at
either full- or half-duplex and can be configured to have flow control enabled or no flow control
independently on a per port basis.
3.8.1 Half Duplex Flow Control (Backpressure)
If the half-duplex flow control option is elected, backpressure will be used for flow control.
Whenever the receive frame buffer of a port is full, the MAC of the port will start sending a JAM
signal through the port. The remote station after sensing the JAM signal will defer transmission.
Backpressure flow control is applied to ensure that there is no dropped frame. The AL103 supports
two types of backpressure, collision based and carrier based.
Carrier based backpressure is generated by the AL103, when the switch port’s frame buffer is full.
The AL103 will cease to jam the line when the port has buffer space available for frame reception.
The IPG of the jamming signal can be selected from 48BT, 56BT, 65BT, 72BT, and 96BT. This can
be selected in register 02 bits 3 and 2. The BpIPGSelEn bit must be set to 1 to select backpressure
IPG less than 96BT.
Collision based backpressure is generated by the AL103, only when the switch port receives a
frame. The AL103 will cease to jam the line, when the line is idle.
The carrier based backpressure has several advantages over collision based backpressure such as:
9/00
Reference Only / Allayer Communications
25
AL103 Revision 1.0
•
Collision based backpressure can cause a late collision.
•
After 16 consecutive collisions, the MAC could drop frames. The AL103 has an
option not to drop frame after 16 collisions. However, the end terminal may still
drop frames.
Therefore, we recommend the use of carrier based backpressure as the preferred method for halfduplex flow control. In this mode of operation, we also recommend that the IPG of the JAM signal
should be set at less than 96BT. This is because if the IPG is at 96 BT, the far end terminal might
still be able to transmit the frame and cause a collision. The excessive collision could cause frames
to be dropped.
The AL103 also supports collision-based backpressure for customers that prefer collision-based
backpressure.
3.8.2 Full Duplex Flow Control (802.3x)
In the full-duplex mode, the AL103 will transmit and receive the frame in accordance to 802.3x.
Note that the transmission channel and the receiving channel operate independently.
In the incoming direction, whenever the receive frame buffer of a port is full, the MAC of the port
will send out a PAUSE frame with its delay value set to maximum. The PAUSE frame will deter any
incoming frame from flowing into the port. After the receive frame buffer is reduced below the
backpressure watermark level (register 04, bit 11:10), the MAC of the port will then send out a
PAUSE frame with the delay value set to zero to resume receiving the incoming frame flow.
In the outgoing direction, whenever a incoming PAUSE frame with a non-zero delay value is
received through a port, the MAC of the port will stop the next frame transmission after the ongoing
frame transmission is finished. It will start its pause timer and resume frame transmission either
after the pause timer expired or when a PAUSE frame with a zero delay value is received.
When the 802.3x flow control option is elected, the device will program the appropriate bit in the
auto-negotiation capability field. When the AL103 is used in the full-duplex mode, it is
recommended that flow control should be turned on which prevents the buffer from overflow and
loss of frames. If the connected device has no 802.3x capability, then the recommended link setting
is half-duplex.
3.9 Queue Management
The AL103 ports have an advanced queue management algorithm for optimal switching
performance. All frames received by AL103 are stored into the shared memory. If the frame is
unicast type, the location of the frame in the buffer is then passed to the destination output queue
manager. It is up to the Destination Output Queue Manger to extract the frame from the buffer and
transmit. If the output queue manager receives more frames than it can send out, it simply stores the
locations of the frames and transmits them after transmitting the current frame.
There are two ways to manage the output queues. One method is that all eight output queues will
share the frame buffer to the shared memory limit, without limit to each individual queue. When
this method is chosen by setting bit 00.15 to “0,” shared buffer memory is allocated to the incoming
frame from any port as long as free buffer is available. When extreme cases of congestion are
experienced, such as traffic merging into a single port or speed mismatch for a long period of time,
a single output queue may occupy the entire shared buffer causing other ports to drop frames. In
9/00
Reference Only / Allayer Communications
26
AL103 Revision 1.0
this case, the flow control option is recommended so when the frame buffer is full, incoming frames
will be backpressured. To prevent buffer starvation, half of the memory is reserved and allocated to
each port while the other half is shared.
The other option is to limit the number of frames that each output queue can store. This option is
selected by setting bit 00.15 to “1.” An output queue watermark can be set in System Configuration
Register I (Register 00, Bits 7:6) to keep the balance between utilization and fairness of buffer
sharing. This method prevents other ports from suffering performance reduction due to a single port
experiencing an extreme congestion. If severe congestion is experienced in a single port, only that
port will suffer from frame loss because the buffer is limited to its dedicated portion. Other ports
will not experience any frame loss due to congestion problem in other ports since all other ports
retain their own allocated buffer space.
When an output queue or multicast queue experiences a buffer full condition, the AL103 will
backpressure the incoming frames if flow control is enabled. A watermark for buffer full condition
can be selected in register 04.
3.10 Uplink Port
The uplink port provides a means to connect the switch with a repeater hub, a workgroup switch, a
router, or any type of interconnecting device compliance with IEEE 802.3 standards.
If flood control is enabled, the AL103 will send all frames with unmatched DA and multicast/
broadcast frames to the uplink port. It is very important that each port is assigned to an uplink port
via the Port Configuration Register (0D to1C), or data frames might be lost. The uplink port should
be configured to be within the same VLAN of the source port. If the uplink port is not a member of
the VLANs, the broadcast or multicast frames will not be forwarded to its designated uplink port.
Multiple VLANs can share the same uplink port.
The AL103 will direct the following frames to the uplink port:
•
Frames with a unicast destination address that doesn’t match with any MAC
address stored in the switch.
•
Frames with a broadcast/multicast destination address if the uplink port is in the
same VLAN.
Note: When configuring an uplink port, the uplink port should designate itself as the uplink port.
3.11 Port Monitoring
The AL103 supports port monitoring. This feature provides complete network monitoring
capability at 100 Mbit/s. A copy of egress (TX) data and ingress (RX) data of the monitored port is
sent to their respective snooping ports.
The monitored port is selected by register 30. The AL103 allows transmit and receive data to be
monitored by different snooping ports. The snooping ports are also selected by register 30.
9/00
Reference Only / Allayer Communications
27
AL103 Revision 1.0
3.12 Media Independent Interface (MII)
The MAC of each port of the AL103 is connected to the PHY through the standard MII interface.
For receiving frames, the received data (RXD[3:0]) is sampled at the rising edge of the receive
clock (RX_CLK). Assertion of the receive data valid (RX_DV) signal will cause the MAC to look
for start of SFD. For transmission, the transmit data enable (TX_EN) signal is asserted when the
first preamble nibble is sent on the transmit data (TXD[3:0]) lines. The transmit data is clocked out
by the rising edge of the transmit clock (TX_CLK).
Prior to any transaction, the AL103 will output 32-bits of “1” as a preamble signal and then after
the preamble, a “01” signal is used to indicate the start of the frame.
3.13 PHY Management
The AL103 supports transceiver management through the serial MDIO and MDC signal lines. The
device provides two modes of management, master and slave mode. In the master mode of
operation, the AL103 controls the operation modes of the link but in the slave mode the PHY
controls the operating mode.
3.13.1 PHY Management MDIO
For a write operation, the device will send a “01” to signal a write operation. Following the “01”
write signal their will be the 5-bit ID address of the PHY device and the 5-bit register address. A
“10” turn around signal is then used to avoid contention during a read transaction. After the turn
around, the 16-bit of data will be written into the register and then after the completion of the write
transaction, the line will be put in a high impedance state.
For a read operation, the AL103 will output a”0” to indicate a read operation after the start of the
frame indicator. Following the “10” read signal will be the 5-bit ID address of the PHY device and
the 5-bit register address. Then, the AL103 will cease driving the MDIO line, and wait for one bit
time. During this time, the MDIO should be in a high impedance state. The device will then
synchronize with the next bit of “0” driven by the PHY device, and continue to read 16-bit of data
from the register. The detail timing requirements on PHY management signals are described in the
section “Timing Requirement.”
3.13.2 PHY Management Master Mode
In the master mode, the AL103 will continuously poll the status of the PHY devices through the
serial management interface. The device will also configure the PHY capability fields to ensure
proper operation of the link.
The configuration of the link is automatic. The link capability is programmed by the AL103
through the port configuration register. The AL103 reads from the standard IEEE PHY registers to
determine the auto-negotiated operating speed and mode. If there is a need to manually set the
operation mode because of flow control and cabling issues the AL103 can set the port operation
mode through the MDIO interface (see EEPROM section for programming the AL103).
3.13.3 PHY Management Slave Mode
In the slave mode, the PHY controls the programming of the operating mode. The AL103 will
continuously poll the status of the PHY devices through the serial management interface to
determine the operation mode of the link.
9/00
Reference Only / Allayer Communications
28
AL103 Revision 1.0
This mode of PHY management is very useful for unmanaged switches. The operating mode of the
link can be changed by programming the mode pin of the PHY through a jumper.
The AL103 also supports 100Base-TX transceivers without a MDIO interface or MII to MII
interface. When MDIO is disabled, the AL103 will operate in the operation mode specified in the
port configuration register (register 0D to 1C).
3.13.4 Non Auto-negotiation Mode
The AL103 can also turn off the auto-negotiation capability of the PHY. When auto-negotiation is
turned off, the AL103 is in the slave mode and the transceiver will determine the link’s operating
mode.
3.13.5 Other PHY Options
Some Legacy Fast Ethernet devices and other low cost devices have no auto-negotiation capability.
In those cases when the transceiver will not be able to perform auto-negotiation, the switch
transceiver will typically do a parallel detection and update the information in the transceiver’s
register. Unfortunately, such register addresses are vendor specific. The AL103 provides a register
(register 05) to specify the register address of the PHY for the AL103 to read. The AL103 will read
from that register and configure the port operation accordingly.
Register 05 also provides some additional flexibility’s for some of the PHYs in the market. In
general, the system designer should set the ID of the PHY devices as 0 for port 0, 1 for port 1, and 7
for port 7. Certain PHYs utilize PHY address 00000 as a broadcast address. Bit 1 of the register 05
allows the AL103 to start with PHY address 01000. This provision allows the engineers to work
around the PHY’s that have problems handling address 00000.
Quad PHYs may have 2-port ordering in the chip pinout, both clockwise and counter clockwise.
Register 05 bit 2, programs the AL103 port order to go in either direction. This provision enables
engineers to easily implement designs with any PHY.
There is also a slow MDIO clock (17 KHz) available for PHY that is not capable of handling a high
speed MDIO clock.
If for some reason, the transceiver is connected to a device and that device fails to auto-negotiate,
the AL103 will default the data rate and duplex mode to the default setting in the port configuration
register.
3.14 EEPROM Interface
The AL103 provides three functions with the EEPROM interface: system initialization, obtaining
system status, and reconfiguring the system in real time. The AL103 uses the 24C02 serial
EEPROM device (2048 bits organized as 256 bits x 8).
3.14.1 System Initialization
The EEPROM interface is provided so that the manufacturer can provide a pre-configured system
to their customers which allows customers to change or reconfigure their system and retain their
preferences. The EEPROM contains configuration and initialization information, which will be
accessed at power up or reset.
9/00
Reference Only / Allayer Communications
29
AL103 Revision 1.0
If the reset pin is held low, the AL103’s EEPROM interface will go into a high impedance state.
This feature is very useful for reprogramming the EEPROM during installation or reconfiguration.
The EEPROM can be reprogrammed by an external parallel port. For reprogramming using a
parallel port, a signal is used to hold the RESET pin low. The EEPROM interface will then be in the
high-impedance state. An external device can then program the EEPROM through the EEDIO and
the EECLK pins. The EEPROM address should be set to 000.
3.14.2 Start and Stop Bit
The write cycle is started by a start bit and ended by a stop bit. A start bit is a transition from high to
low of EEDIO when EEC is high. The operation terminates when EEDIO goes from low to high
when EEC is high. Following a start condition, the writing device must output the address of the
EEPROM. The most significant four bit of the EEPROM address is the device type identifier which
has an address of 1010. The EEPROM device address should be set to 000.
EECLK
EEDIO
Data or
Address
Valid
START
BIT
Figure 5
Data
Change
STOP BIT
EEPROM Start and Stop Bit
3.14.3 Write Cycle Operation
The EECLK is an output from the AL103 while EEDIO is a bi-directional signal. When accessing
the EEPROM, the reset pin has to be held low or initialization of the AL103 must be finished before
a writing operation can begin. A typical write operation is shown in Figure 6.
Start
S
Device
Address
A A
Stop
A
8-Bit Word Address
Acknowledge
Figure 6
9/00
Acknowledge
8-Bit Data n
S
Acknowledge
EEPROM Write Cycle
Reference Only / Allayer Communications
30
AL103 Revision 1.0
3.14.4 Read Cycle Operation
Read operations are initiated in the same manner as write operations, with the exception that the R/
W bit of the EEPROM address is set to a “1.”
Start
S
Device
Address
A A
Start
A
8-Bit Word Address
S
Device
Address
A A
Stop
A
8-Bit Data n
S
EEDIO
Acknowledge
Figure 7
Acknowledge
Acknowledge
No Acknowledge
EEPROM Read Cycle
3.14.5 Reprogramming the EEPROM Configuration
There are two ways that the system can be reconfigured. Figure 8 shows an application using the
parallel interface to reprogram the EEPROM. In this application, the parallel port holds the reset
pins low, which forces the EEDIO pins to go into high impedance. Once the pins are in high
impedance, the EEPROM can now be programmed by the parallel port. Once the parallel port
releases the reset pins, the devices will start to download the EEPROM data and reconfigure the
devices.
An alternate way of reconfiguring the system is to directly change the register settings of the
AL103. After initialization, the EEPROM interface can act as a virtual EEPROM. In order for this
method to work, the EEPROM’s device address must be 000, while the AL103’s address will be
100. The customer can now program the AL103 as an EEPROM. The read and write timing is the
same as an EEPROM.
Because you read as well as write to the AL103, the registers status can be read from the AL103.
This will serve as a very useful tool for diagnostic of an unmanaged switch.
9/00
Reference Only / Allayer Communications
31
AL103 Revision 1.0
Reset
Parallel Port
AL103
EECLK
EEPROM
EEDIO
Figure 8
EEPROM Parallel Port
3.14.6 EEPROM Map
Table 17 shows the EEPROM address map cross-referenced to the register/bit set of the AL103.
Addresses 00 through 6D are for configuring the device. They are downloaded by the AL103 after
reset or power up. Since the AL103 registers are 16-bit wide, it takes two EEPROM addresses for
each AL103 register. Even numbered EEPROM addresses corresponds to the upper byte of the
AL103 registers while the odd numbered EEPROM addresses corresponds to the lower byte of the
AL103 registers.
Address 06 and 07 should be programmed as 0000 0001 and 0001 0100. The address 6F indicates
the last address entry. If no static address is used in the switch, the address 6F should be
programmed. Addresses 70 to FF are used for programming the static address entry.
The following format is an example of Static Entry 1, Address 70-7F.
Table 17: Static Address Entry Format for EEPROM
EEPROM
ADDRESS
BIT
7
6
5
70
Reserved (Must be all zero)
71
Reserved
72
MAC Address [47:40]
73
MAC Address [39:32]
74
MAC Address[31:24]
75
MAC Address[23:16]
76
MAC Address[15:8]
77
MAC Address[7:0]
4
3
2
1
0
Port ID 000XXX or Trunk ID 100YYY
Note: XXX represents port ID and YYY represents Trunk ID.
9/00
Reference Only / Allayer Communications
32
AL103 Revision 1.0
Table 18: AL103 EEPROM Mapping
EEPROM PHYSICAL
ADDRESS
9/00
DESCRIPTION
00-01
System Configuration I
02-03
System Configuration II
04-05
System Configuration III
06-07
Reserved (Value must be 0000 0001 0100)
08-09
Reserved
0A-0B
Vendor Specific PHY
0C-0D
Port Monitoring Configuration
0E-0F
Reserved
10-11
Reserved
12-13
Reserved
14-15
Reserved
16-17
Reserved
18-19
Reserved
1A-1B
Port 0 Configuration I
1C-1D
Port 0 Configuration II
1E-1F
Port 1 Configuration I
20-21
Port 1 Configuration II
22-23
Port 2 Configuration I
24-25
Port 2 Configuration II
26-27
Port 3 Configuration I
28-29
Port 3 Configuration II
2A-2B
Port 4 Configuration I
2C-2D
Port 4 Configuration II
2E-2F
Port 5 Configuration I
30-31
Port 5 Configuration II
32-33
Port 6 Configuration I
34-35
Port 6 Configuration II
36-37
Port 7 Configuration I
Reference Only / Allayer Communications
33
AL103 Revision 1.0
Table 18: AL103 EEPROM Mapping (Continued)
38-39
Port 7 Configuration II
3A-3B
Reserved (Must be all zero)
3C-3D
Port 0 VLAN Map
3E-3F
Reserved (Must be all zero)
40-41
Port 1 VLAN Map
42-43
Reserved (Must be all zero)
44-45
Port 2 VLAN Map
46-47
Reserved (Must be all zero)
48-49
Port 3 VLAN Map
4A-4B
Reserved (Must be all zero)
4C-4D
Port 4 VLAN Map
4E-4F
Reserved (Must be all zero)
50-51
Port 5 VLAN Map
52-53
Reserved (Must be all zero)
54-55
Port 6 VLAN Map
56-57
Reserved (Must be all zero)
58-59
Port 7 VLAN Map
5A-5B
Miscellaneous Register
5C-5D
Checksum
5E-5F
Port 0 to Trunk Port Assignment
60-61
Port 1 to Trunk Port Assignment
62-63
Port 2 to Trunk Port Assignment
64-65
Port 3 to Trunk Port Assignment
66-67
Port 4 to Trunk Port Assignment
68-69
Port 5 to Trunk Port Assignment
6A-6B
Port 6 to Trunk Port Assignment
6C-6D
Port 7 to Trunk Port Assignment
6E
Reserved
6F
Last Static Entry EEPROM Address
(Value must be 6F for no Static Entry)
70-77
9/00
Static Entry 1
Reference Only / Allayer Communications
34
AL103 Revision 1.0
Table 18: AL103 EEPROM Mapping (Continued)
9/00
78-7F
Static Entry 2
80-87
Static Entry 3
88-8F
Static Entry 4
90-97
Static Entry 5
98-9F
Static Entry 6
A0-A7
Static Entry 7
A8-AF
Static Entry 8
B0-B7
Static Entry 9
B8-BF
Static Entry 10
C0-C7
Static Entry 11
C8-CF
Static Entry 12
D0-D7
Static Entry 13
D8-DF
Static Entry 14
E0-E7
Static Entry 15
E8-EF
Static Entry 16
F0-F7
Static Entry 17
F8-FF
Static Entry 18
Reference Only / Allayer Communications
35
AL103 Revision 1.0
3.15 SGRAM Interface
All ports of the AL103 work in Store-And-Forward mode so that all ports can support both 10
Mbps and 100 Mbps data speed. The AL103 utilizes a central memory buffer pool, which is shared
by all ports within the same device. After a frame is received, it is passed across the SGRAM
interface and stored in the buffer. During transmit, the frame is retrieved from the buffer pool and
forwarded to the destination port.
The AL103 is designed to use 8 Mbit SGRAM or 16 Mbit SGRAM to achieve low cost and high
performance.
The SGRAM is accessed in Page Burst Access Mode for very high-speed access. This burst mode
is repeatedly sent to the same column. If burst mode reaches the end of the column address, it then
wraps around to the first column address (=0) and continues to count until interrupted by the new
read/write, pre-charge, or a burst stop command.
The AL103 will initialize the SGRAM automatically and pre-charges all banks and inserts eight
auto–refresh commands. It will also program the mode registers for the AL103’s read and write
operations.
SGRAM essentially is a SDRAM. Dynamic memories must be refreshed periodically to prevent
data loss. The SGRAM uses refresh address counters to refresh automatically. The SGRAM autorefresh command generates a pre-charge command internally in the SGRAM. The AL103 will
insert an auto-refresh command once every 15 microseconds.
4. Register Description
Table 19: Register Tables Summary
REGISTER ID
REVERSE
EEPROM
ADDRESS
00
System Configuration I
00,01
01
System Configuration II
02,03
02
System Configuration III
04,05
03
Reserved
06,07
04
Testing Register
08,09
05
Vendor Specific PHY Status
0A,0B
Reserved
0C-19
0D
Port 0 Configuration I
1A,1B
0E
Port 0 Configuration II
1C,1D
0F
Port 1 Configuration I
1E,1F
10
Port 1 Configuration II
20,21
06-0C
9/00
REGISTER DESCRIPTION
Reference Only / Allayer Communications
36
AL103 Revision 1.0
Table 19: Register Tables Summary (Continued)
9/00
11
Port 2 Configuration I
22,23
12
Port 2 Configuration II
24,25
13
Port 3 Configuration I
26,27
14
Port 3 Configuration II
28,29
15
Port 4 Configuration I
2A,2B
16
Port 4 Configuration II
2C,2D
17
Port 5 Configuration I
2E,2F
18
Port 5 Configuration II
30,31
19
Port 6 Configuration I
32,33
1A
Port 6 Configuration II
34,35
1B
Port 7 Configuration I
36,37
1C
Port 7 Configuration II
38,39
1D
Reserved
3A,3B
1E
Port 0 VLAN Map
3C,3D
1F
Reserved
3E,3F
20
Port 1 VLAN Map
40,41
21
Reserved
42,43
22
Port 2 VLAN Map
44,45
23
Reserved
46,47
24
Port 3 VLAN Map
48,49
25
Reserved
4A,4B
26
Port 4 VLAN Map
4C,4D
27
Reserved
4E,4F
28
Port 5 VLAN Map
50,51
29
Reserved
52,53
2A
Port 6 VLAN Map
54,55
2B
Reserved
56,57
2C
Port 7 VLAN Map
58,59
2D
Miscellaneous Register
5A,5B
2E
Port 0 to Trunk Port Assignment
5C,5D
Reference Only / Allayer Communications
37
AL103 Revision 1.0
Table 19: Register Tables Summary (Continued)
2F
Port 1 to Trunk Port Assignment
5E,5F
30
Port 2 to Trunk Port Assignment
60,61
31
Port 3 to Trunk Port Assignment
62,63
32
Port 4 to Trunk Port Assignment
64,65
33
Port 5 to Trunk Port Assignment
66,67
34
Port 6 to Trunk Port Assignment
68,69
35
Port 7 to Trunk Port Assignment
6A,6B
Reserved
6C-71
39
System Status Register
72,73
3A
Port 0 Operation Status
74,75
3B
Port 1 Operation Status
76,77
3C
Port 2 Operation Status
78,79
3D
Port 3 Operation Status
7A,7B
3E
Port 4 Operation Status
7C,7D
3F
Port 5 Operation Status
7E,7F
40
Port 6 Operation Status
80,81
41
Port 7 Operation Status
82,83
42
Indirect Resource Access Command
84,85
43
Indirect Resource Access Data I
86,87
44
Indirect Resource Access Data II
88,89
45
Indirect Resource Access Data III
8A,8B
46
Indirect Resource Access Data IV
8C,8D
47
Check Sum
8E,8F
36-38
9/00
Reference Only / Allayer Communications
38
AL103 Revision 1.0
System Configuration Register I (Register 00)
System Configuration Registers 01 ~ 03 are global system configuration registers. Any options
selected in these registers affects the overall system operation.
Table 20: System Configuration Register I (Register 00)
9/00
BIT
NAME
DESCRIPTION
15
OutQMgmt
Output Queue Management Method.
0: Output queue is not limited until the frame buffer is full.
1: Output queue is limited to the output queue watermark specified in
register 00 bits [7:6].
14
FloodCtl
Flood Control. Control for the forwarding of unicast frames with
unknown destination received from the non-uplink ports.
0: Enable. Frames received with unknown unicast destination MAC
address will be forwarded to all the ports (excluding the receiving port)
within the VLANs specified at the receiving port.
1: Disable. Frames received with unknown unicast destination MAC
address will be forwarded to the uplink port specified for the receiving
port.
13
SecMgmt
Security Enforcement.
0: Auto security off. The security violation at a secured port will not
change its port state.
1: Auto security on. The security violation at a secured port will cause
the port into DISABLE state.
12
AgeEn
11~10
Reserved
9
PInMon
Port Incoming Frame Flow Monitoring Enable Control.
0: Disable
1: Enable
8
POutMon
Port Outgoing Frame Flow Monitoring Enable Control.
0: Disable
1: Enable
7~6
OutQWM
Output Queue Watermark. Watermark selection for output queues
and multicast queue full conditions.
16 Mbit/s SGRAM
00:128; 01:512; 10:768; 11:Test Mode.
8 Mbit/s SGRAM
00:64; 01:256; 10:384; 11:Test Mode.
5~4
Reserved
Set value to 00.
Switch Table Entry Aging Control.
0: Disable. The table aging process will be stopped.
1: Enable. The table aging process will be running to age every
dynamically learned table entry.
Reserved (Must set to 0000).
Reference Only / Allayer Communications
39
AL103 Revision 1.0
Table 20: System Configuration Register I (Register 00) (Continued)
3
L2Trunk
Layer 2 Trunk Loading Method.
0: Port based loading. Trunking decisions will be based on Trunk Port
Assignment Registers.
1: MAC address based loading. Trunking decisions will be based on
source port MAC addresses.
2
TimeoutEN
1~0
Reserved
Frame Time Out Enable.
0: Device will not timeout frames based on MaxDelay.
1: Device will timeout frames.
Reserved (Must set to 00).
Table 21: System Configuration Register II (Register 01)
9/00
BIT
NAME
DESCRIPTION
15~8
MaxAge
Maximum Age For Dynamically Learned MAC Entries.
0000 0000: 1 sec. to 1111 1111: 256 sec.
7~6
MaxDelay
Maximum Frame Transition Delay Through The Switch.
00: 1 second.
01: 2 seconds.
10: 3 seconds.
11: 4 seconds.
5~4
MaxStorm
Maximum Number of Broadcast Frames That Can Be Accumulated In
Each Input Frame Buffer.
00: 16 frames.
01: 32 frames.
10: 48 frames.
11: 64 frames.
3
SuperMAC
0: Disable. Device will perform the IEEE standard exponential back-off
algorithm when a collision occurs.
1: Enable. When collisions occur, the AL103 will back off up to 3 slots.
2
REC
1~0
L2TbitSel
Retry on Excessive Collision.
0: Normal collision handling.
1: Retry transmission after 16 consecutive collisions.
Select the Bits Position for MAC Address To Trunk Assignment.
00: Source MAC address [1:0].
01: Source MAC address [3:2].
10: Source MAC address [5:4].
11: Source MAC address [7:6].
Reference Only / Allayer Communications
40
AL103 Revision 1.0
Table 22: System Configuration Register III (Register 02)
9/00
BIT
NAME
DESCRIPTION
15
Reserved
14
DISPHYReset
13
Skip_Reg6
12~11
Reserved
10
AgeRes
9
BpIPGSelEn
8
IPG64
7~6
Reserved
5
SG16M
SGRAM Select.
0: 8 Mbit SGRAM
1: 16 Mbit SGRAM
4
BPCOL
Backpressure Control.
0: Carrier based.
1: Collision based.
3~2
BpIPGSel
Backpressure IPG Select.
00: 48BT; 01: 56BT; 10: 65BT; 11: 72BT.
1
Reserved
Reserved
0
BCdrop_SC
Reserved (Must set to 0).
PHY Reset Option.
0: Reset PHY on link down.
1: Don’t reset PHY on link down.
Enable skip register 6 read during auto-negotiation for Seeq PHY.
0: Don’t skip.
1: Skip
Reserved (Must set to 0).
Age Resolution.
0: Normal aging.
1: Slow down aging.
Backpressure IPG Select Enable.
0: Backpressure IPG = 96BT.
1: According to BpIPGSel value.
IPG Control.
0: IPG = 96BT
1: IPG = 64BT
Reserved
0: Flow control multicast.
1: Flow control multicast/broadcast.
Reference Only / Allayer Communications
41
AL103 Revision 1.0
Reserved Register (Register 03)
This register is reserved for Allayers use. The bits should be set as 0000 0001 0001 0100.
Testing Register (Register 04)
Most of the bits in this register are reserved for factory testing except for the WmarkSel bits. These
bits set the level of buffer to trigger backpressure to eliminate buffer overflow.
Table 23: Testing Register (Register 04)
BIT
NAME
DESCRIPTION
15~12
Reserved
Reserved
11~10
WmarkSel
Backpressure Watermark Select.
00: Backpressure if available block count < 4.
01: Backpressure if available block count < 8.
10: Backpressure if available block count < 16.
11: Backpressure if available block count < 28 (8 Mbit/s SGRAM).
11: Backpressure if available block count < 60 (16 Mbit/s SGRAM).
Each block is 2K byte.
9~0
Reserved
Reserved
Vendor Specific PHY Register (Register 05)
This register is used to program vendor-specific PHY options. It is also used for programming the
Vendor Specific PHY register location and bit location of the operation status.
Table 24: Vendor Specific PHY Register (Register 05)
9/00
BIT
NAME
DESCRIPTION
15
PHYAD
Setting this bit to “1” will program the MDIO PHY address to 16 to 23.
14
MclkSpd
Setting this bit to “1” will reduce the MDIO clock speed to 17 KHz.
13
PortOrder
Setting this bit to “1” will reverse the PHY ID/port number of the switch.
12~8
PHYOpReg
7~4
PHYSpBit
3~0
PHYDxMode
PHY’s Operation Status Register Number.
PHY’s Data Rate Status Register Bit Number.
PHY’s Operating Duplex Mode Status Register Bit Number.
Reference Only / Allayer Communications
42
AL103 Revision 1.0
Table 25: Port Monitoring Configuration (Register 06)
BIT
NAME
DESCRIPTION
15
Reserved
14~10
MdPID
Monitored Port ID.
9~5
MgIPID
Snooping Port ID for Incoming Frame Flow.
4~0
MgOPID
Snooping Port ID for Outgoing Frame Flow.
Reserved
Reserved Registers (Registers 07 to 0C)
These registers are reserved and must be set to zero.
Port Configuration Registers (Registers 0D to 1C)
Registers 0D to 1C are for local port configuration. There are two port configurations per port. Port
0 port configuration uses register 0D and 0E, Port 1 register 0F and 10, etc.
Table 26: Port Configuration Register I
9/00
BIT
NAME
DESCRIPTION
15~10
UpLinkID
Uplink ID Associated with the Port.
0XXYYY: Port ID with XX as the device ID and YYY as the port ID.
100XXN: Trunk ID with XX as the device ID and N as the trunk ID.
Others: Reserved
9
Tmember
Trunk Member Port.
0: Individual port.
1: Member of trunk port.
8
Reserved
Reserved (Set to 0).
7
StormCTL
Broadcast Storm Control Enable.
0: Storm control disable. The broadcast frame will not be throttled.
1: Storm control enable. If the accumulated number of broadcast
frames in the input buffer of the port is over the threshold specified in
the system configuration register, new incoming broadcast frames will
be discarded until the number has been reduced below the threshold.
6
Security
Intrusion Protection. Security control for the frames received from nonuplink ports.
0: Security off. The forwarding decision made about frames received
from the port will not involve the source MAC address checking.
1: Security on. The frames received from the port with unknown
source MAC address or with source MAC address learned previously
from another port will be discarded.
5
Reserved
Reserved (Set to 0).
Reference Only / Allayer Communications
43
AL103 Revision 1.0
Table 26: Port Configuration Register I (Continued)
4
LrnDis
Learning Disable.
0: Source address from this port will be learned.
1: Source address from this port will not be learned.
3~2
Reserved
Must set to 11.
1~0
Reserved
Reserved (Set to 0).
Table 27: Port Configuration Register II
9/00
BIT
NAME
DESCRIPTION
15~14
Reserved
Reserved
13
Reserved
Reserved (Set to 0).
12
SkipANDone
Ignore Auto-Negotiation Complete and Wait for Link Up.
11
FlowCtrlFdEn
Flow Control Full-duplex Enable.
10
FlowCtrlHdEn
Flow Control Half-duplex Enable.
9~6
MDIOCfg[3:0]
MDIO Configuration.
0001: Master mode PHY management.
0010: Slave mode PHY management.
0111: Force mode.
5
MDIODis
4
LinkUp
3
PrtMode100F
Force 100 Full-duplex Mode.
2
PrtMode100H
Force 100 Half-duplex Mode.
1
PrtMode10F
Force 10 Full-duplex Mode.
0
PrtMode10H
Force 10 Half-duplex Mode.
MDIO Disable.
0: MDIO is enabled.
1: MIDO is disabled.
This bit is not relevant when MDIO is enabled. When MDIO is
disabled, this bit forces the port into link up or link down state.
Reference Only / Allayer Communications
44
AL103 Revision 1.0
Port VLAN Map Registers (Registers 1E to 2C)
These registers provide the VLAN map for each port. Registers 1D, 1F, 21, 23, 25, 27, 29, and 2B
are reserved. The values for these reserved registers should be all zero.
A VLAN worksheet is provided in Appendix I.
Table 28: Port VLAN Map Registers (Registers 1E to 2C)
9/00
BIT
NAME
DESCRIPTION
15~8
Reserved
7
Port7VLAN
Port VLAN Corresponding to the Port 7.
0: Non-member port.
1: Member port.
6
Port6VLAN
Port VLAN Corresponding to the Port 6.
0: Non-member port.
1: Member port.
5
Port5VLAN
Port VLAN Corresponding to the Port 5.
0: Non-member port.
1: Member port.
4
Port4VLAN
Port VLAN Corresponding to the Port 4.
0: Non-member port.
1: Member port.
3
Port3VLAN
Port VLAN Corresponding to the Port 3.
0: Non-member port.
1: Member port.
2
Port2VLAN
Port VLAN Corresponding to the Port 2.
0: Non-member port.
1: Member port.
1
Port1VLAN
Port VLAN Corresponding to the Port 1.
0: Non-member port.
1: Member port.
0
Port0VLAN
Port VLAN Corresponding to the Port 0.
0: Non-member port.
1: Member port.
Should be set to 0.
Reference Only / Allayer Communications
45
AL103 Revision 1.0
Table 29: Miscellaneous Register (Register 2D)
BIT
NAME
DESCRIPTION
15~11
Reserved
Set value to 0.
10
L2DASA
Select the Algorithm for MAC Based Loading.
0: SA only.
1: SA and DA.
9
L2Fail
8
L2MAP
7~4
TrunkMap1
MAC Based Trunk Port Mapping for Trunk 1.
0: Non-trunk port.
1: Trunk port.
3~0
TrunkMap0
MAC Based Trunk Port Mapping for Trunk 0.
0: Non-trunk port.
1: Trunk port.
Trunk Link Fail Over.
0: Don’t fail-over when a trunk port fails.
1: Allow link fail-over for trunking.
Enable 2 or 3 Port MAC Based Trunking Option.
0: Disable
1: Enable
Port Trunk Port Assignment Registers (Registers 2E to 35)
The Port to Trunk Port assignment register assigns a port to a trunk for port-based load balancing
trunking. Please see example in the trunking section.
A port to trunk port work sheet is provided in Appendix II.
Table 30: Port Trunk Port Assignment Registers (Registers 2E to 35)
9/00
BIT
NAME
DESCRIPTION
15~4
Reserved
3~2
Trunk1
Trunk Port of Trunk 1.
00: Port 4
01: Port 5
10: Port 6
11: Port 7
1~0
Trunk0
Trunk Port of Trunk 0.
00: Port 0
01: Port 1
10: Port 2
11: Port 3
Should be set to 0.
Reference Only / Allayer Communications
46
AL103 Revision 1.0
Table 31: System Status Register (Register 39)
BIT
NAME
DESCRIPTION
15
EPTimeOut
14
Sgraminitdone
SGRAM Initialization Done.
0: SGRAM initialization is not done.
1: SGRAM initialization is done.
13
Sraminitdone
SRAM Initialization Done.
0: SRAM initialization is not done.
1: SRAM initialization is done.
12
Reginitdone
Register Initialization Done.
0: AL103 register initialization is not done.
1: AL103 register initialization is done.
11~8
TrafCnt
7~4
Reserved
Reserved
3~0
Version ID
0101: AL103
EEPROM Time Out.
0: EEPROM initialized the device.
1: EEPROM is not found. Default configuration.
Traffic Counter.
0000: Minimum traffic.
1111: Maximum traffic.
Port Operation Status Registers (Register 3A to 41)
Registers 3A to 41 are status indication on a per port basis. These are read only register. Port 0 port
status is in register 3A; Port 1 register 3B…and port 7 register 41.
Table 32: Port Operation Status Registers (Register 3A to 41)
9/00
BIT
NAME
DESCRIPTION
15
LinkFail
Port Link Status.
0: Normal
1: Fail
14
PHYError
Port PHY Status.
0: Normal
1: Error
13
Sviolation
Port Security Violation.
0: Normal
1: Violation
Reference Only / Allayer Communications
47
AL103 Revision 1.0
Table 32: Port Operation Status Registers (Register 3A to 41) (Continued)
9/00
12
FlowCtrl
Flow Control.
If port mode ([1:0]) is 2’b01 or 2’b11:
0: Pause disable.
1: Pause enable.
If port mode ([1:0]) is 2’b00 or 2’b10:
0: Backpressure based on CRS.
1: Backpressure based on collision.
11
Stormed
Port Broadcast Storm Status.
0: Normal
1: Stormed
10
InBFull
9
TblUNAVL
Table Entry Unavailability for MAC Learning.
0: Normal.
1: Unavailability experienced.
8
Jabbered
Port Jabber Status.
0: Normal
1: Jabber experienced.
7
LateCOL
Port Late Collision Status.
0: Normal
1: Late collision experienced.
6
TxPaused
Port Transmit Pause Status.
0: No transmit pause experienced.
1: Transmit pause experienced.
5
CRSLoss
Port Carrier Sense Loss During Transmission Status.
0: No carrier sense loss experienced.
1: Carrier sense loss experienced.
4
FalseCRS
False Carrier Status.
3
Underflow
Transmit Queue Underflow Status.
0: Normal
1: Underflow experienced.
2
TimeOut
Frame Time Out.
0: Normal
1: Frame time out experienced.
1~0
PortMode
Port Operating Mode.
00: 10 Mb half-duplex.
01: 10 Mb full-duplex.
10: 100 Mb half-duplex.
11: 100 Mb full-duplex.
Port Input Buffer Full Status.
0: Normal
1: Input buffer full experienced.
Reference Only / Allayer Communications
48
AL103 Revision 1.0
Indirect Resource Access Command Register (Register 42)
Indirect resource access command allows the management (Reverse EEPROM Method) to access
other resources other than the AL103 register values. PHY registers, both internal and external
MAC address tables, and SGRAM contents can be accessed using this command.
Table 33: Indirect Resource Access Command Register (Register 42)
9/00
BIT
NAME
DESCRIPTION
15
CmdDone
Command Done.
0: Execute new command.
1: Command done.
Clear this bit to execute a new command. When finished with the
command, the AL103 will set the bit back to “1.”
14
Operation
Read/Write Operation Command.
0: Read operation.
1: Write operation.
13~11
ResType
Type of Accessed Resource.
000: PHY registers.
001: EEPROM
010: SGRAM
011: MAC address table 1;
Read: MAC table address read.
Write: MAC address learn.
100: MAC address table 2;
Read: MAC address search.
Write: MAC address delete.
101-111: Reserved
10
ExtRD
10~0
ResAddr
External MAC Address Table Read.
If ResType = 011 and Operation = 0
0: On-chip address table read.
1: Off-chip address table read.
The Address of the Entry Within the Accessed Resource.
Reference Only / Allayer Communications
49
AL103 Revision 1.0
Indirect Resource Access Data Registers
Indirect Resource Access Data I through IV is used with indirect resource access command.
Table 34: Indirect Resource Access Data I Register (Register 43)
BIT
NAME
DESCRIPTION
15~0
IRAData
Indirect Resource Access Data 1.
Table 35: Indirect Resource Access Data II Register (Register 44)
BIT
NAME
DESCRIPTION
15~0
IRAData
Indirect Resource Access Data 2.
Table 36: Indirect Resource Access Data III Register (Register 45)
BIT
NAME
DESCRIPTION
15~0
IRAData
Indirect Resource Access Data 3.
Table 37: Indirect Resource Access Data IV Register (Register 46)
BIT
NAME
DESCRIPTION
15~0
IRAData
Indirect Resource Access Data 4.
Table 38: Check Sum (Register 47)
9/00
BIT
NAME
DESCRIPTION
15~8
CheckSum
7~0
Reserved
Check Sum Value of AL103 Register Contents.
Reference Only / Allayer Communications
50
AL103 Revision 1.0
5. Timing Requirements
Table 39: MII Transmit Timing
SYMBOL
DESCRIPTION
MIN
TYP
MAX
UNIT
ttdv
TXCLK to TXD valid time.
4
-
12
ns
ttxev
TXCLK to TXEN valid time.
4
-
12
ns
TXCLK
ttxev
ttxev
TXEN
ttdv
TXD
Figure 9
DATA
DATA
DATA
DATA
DATA
DATA
MII Transmit Timing
Table 40: MII Receive Timing
SYMBOL
DESCRIPTION
MIN
TYP
MAX
UNIT
trxds
RX_DV, RXD, RX_ER, setup
time.
10
-
-
ns
trxdh
RX_DV, RXD, RX_ER hold time.
5
-
-
ns
RXCLK
trxdh
RXEN
trxds trxdh
RXD
Figure 10
9/00
DATA
DATA
DATA
DATA
DATA
DATA
MII Receive Timing
Reference Only / Allayer Communications
51
AL103 Revision 1.0
Table 41: PHY Management (MDIO) Read Timing
SYMBOL
DESCRIPTION
MIN
TYP
MAX
UNIT
tch
MDC high time.
420
425
430
ns
tcl
MDC low time.
420
425
430
ns
tmc
MDC period.
840
850
860
ns
tms
MDIO setup time.
10
-
15
ns
tmh
MDIO hold time.
10
-
-
ns
MDC
tcl
tch
tmc
tms
tmh
MDIO
Figure 11
9/00
PHY Management Read Timing
Reference Only / Allayer Communications
52
AL103 Revision 1.0
Table 42: PHY Management (MDIO) Write Timing
SYMBOL
DESCRIPTION
MIN
TYP
MAX
UNIT
tch
MDC high time.
420
425
430
ns
tcl
MDC low time.
420
425
430
ns
tmc
MDC period.
840
850
860
ns
MDIO output delay.
40
-
52
ns
td
MDC
tcl
tch
tmc
td
MDIO
Figure 12
PHY Management Write Timing
Table 43: SGRAM Refresh Timing
SYMBOL
9/00
DESCRIPTION
MIN
TYP
MAX
UNIT
tAH
Access hold time.
1
-
-
ns
tAS
Access setup time.
3
-
-
ns
tCH
PBCS#, PBRAS#, PBWE# hold time.
1
-
-
ns
tCHI
Clock high level width.
3.5
-
-
ns
tCK
System clock cycle time.
10
-
-
ns
tCKH
CKE hold time.
1
-
-
ns
tCKS
CKE setup time.
3
-
-
ns
3.5
-
-
ns
tCL
Clock low level width.
tCS
PBCS#, PBRAS#, PBWE# setup time.
3
-
-
ns
tRP
Precharge command period.
30
-
-
ns
tRC
Auto-refresh to auto-refresh period.
90
-
-
ns
Reference Only / Allayer Communications
53
AL103 Revision 1.0
PBCLK
tCK
tCHI
tCL
tCKS tCKH
CKE
tCS
Command
tCH
Precharge
Auto
Refresh
NOP
NOP
Auto
Refresh
NOP
BANK
ROW
BANK
tRC
tRP
Address
Active
tRC
Don't Care
Figure 13
9/00
SGRAM Refresh Timing
Reference Only / Allayer Communications
54
AL103 Revision 1.0
Table 44: SGRAM Read Timing
SYMBOL
DESCRIPTION
MIN
TYP
MAX
UNIT
tAC
Access time.
-
-
10
ns
tAH
Access hold time.
2
-
-
ns
tAS
Access setup time.
2.5
-
-
ns
tCH
PBCS#, PBRAS#, PBWE# hold
time.
1
-
-
ns
tCHI
Clock high level width.
3
-
-
ns
tCK
System clock cycle time.
13
-
-
ns
tCKH
CKE hold time.
2
-
-
ns
tCKS
CKE setup time.
3
-
-
ns
tCL
Clock low level width.
3
-
-
ns
tCS
PBCS#, PBRAS#, PBWE#
setup time.
2.5
-
-
ns
tHZ
Data out high impedance time.
-
-
8
ns
tLZ
Data out low impedance time.
2
-
-
ns
tOH
Data out hold time.
2
-
-
ns
tRAS
Active to precharge command
period.
48
-
-
ns
tRCD
Active to read delay.
24
-
-
ns
Note: This timing requirement is for a SGRAM running at CAS Latency 2. Typically
a -8 speed grade SGRAM needs to be used.
9/00
Reference Only / Allayer Communications
55
AL103 Revision 1.0
tCK
tCL
tCHI
PBCLK
tCKH
tCKS
CKE
tCS tCH
Command
Active
A0-A7
ROW
A8
ROW
tAS
PBBA
NOP
READ
NOP
NOP
NOP
NOP
NOP
BURST
TERM.
NOP
column m
tAH
BANK 0
BANK 0
tAC
tAC
tOH
Dout
m
PBD
Dout
m+1
Dout
m+2
Dout
m-1
Dout
m
Dout
m+1
tLZ
CAS Latency
tRCD (Bank 0)
256 location within the same row
tHZ
tRAS (Bank 0)
Figure 14
9/00
SGRAM Read Timing
Reference Only / Allayer Communications
56
AL103 Revision 1.0
Table 45: SGRAM Write Timing
SYMBOL
DESCRIPTION
MIN
TYP
MAX
UNIT
tAH
Access hold time.
2
-
-
ns
tAS
Access setup time.
2.5
-
-
ns
tCH
PBCS#, PBRAS#, PBWE# hold
time.
1
-
-
ns
tCHI
Clock high level width.
3
-
-
ns
tCK
System clock cycle time.
13
-
-
ns
tCKH
CKE hold time.
2
-
-
ns
tCKS
CKE setup time.
3
-
-
ns
tCL
Clock low level width.
3
-
-
ns
tCS
PBCS#, PBRAS#, PBWE#
setup time.
2.5
-
-
ns
tDH
Data in hold time.
1
-
-
ns
tDS
Data in setup time.
2.5
-
-
ns
tRAS
Active to precharge command
period.
48
-
100,000
ns
tRCD
Active to read delay.
24
-
-
ns
Note: This timing requirement is for a SGRAM running at CAS Latency 2. Typically
a -8 speed grade SGRAM needs to be used.
9/00
Reference Only / Allayer Communications
57
AL103 Revision 1.0
tCK
tCHI
PBCLK
tCKS
tCKH
tCL
CKE
tCS tCH
Command
Active
A0-A7
ROW
A8
ROW
tAS
PBBA
NOP
write
NOP
NOP
NOP
NOP
NOP
tAH
BANK 0
PBD
BANK 0
tDH
Din m
Din
m+1
Din
m+2
Din
m+3
Din
m-1
Din m
Don't Care
tRCD (Bank 0)
256 location within the same row
tRAS (Bank 0)
9/00
BURST
TERM.
column m
tDS
Figure 15
NOP
Undefined
SGRAM Write Timing
Reference Only / Allayer Communications
58
AL103 Revision 1.0
6. Electrical Specifications
Note: Operation at absolute maximum ratings for an extended period of time could
cause permanent damage to the device.
Table 46: Maximum Ratings
DC Supply Voltage (Vcc)
-0.3V ~ + 3.6V
DC Input Voltage
-0.3 ~ Vcc + 0.3V
DC Output Voltage
-0.3 ~ Vcc + 0.3V
DC Supply Voltage to MII
-0.6V to 6.0V
DC Input Voltage to MII
-0.6 to Vcc5 + 0.3V
DC Output Voltage to MII
-0.6 to Vcc5 + 0.3V
Storage Temperature
-55 oC to +150 oC
Table 47: Recommended Operation Conditions
Supply Voltage
3.3V ± 0.3V
Operating Temperature
0 oC to 70 oC
Power Dissipation
1.7 W (typical)
Table 48: DC Electrical Characteristics
PARAMETER
9/00
DESCRIPTION
MIN
TYP
MAX
UNIT
Voh
Output voltage-high, Ioh=4mA
2.4
-
-
V
Vol
Output voltage-low, Ioh=4mA
-
-
0.4
V
Ioz
High impedance state output
current
-10
-
10
uA
Iih
Input current-high
(With no pull-up or pull-down)
-10
-
10
uA
Iil
Input current-low
(With no pull-up or pull-down)
-10
-
10
uA
Vih
Input high voltage
0.7*Vcc
-
-
V
Vil
Input low voltage
-
-
0.3*Vcc
V
Icc
Supply current
-
-
-
mA
Reference Only / Allayer Communications
59
AL103 Revision 1.0
7. AL103 Mechanical Data
256 PQFP Package
25.2
0.18 ± 0.04
0.40
28.00 ± 0.10
30.6 ± 0.15
3.23 ± 0.07
4.07 max.
0.60 ± 0.10
0.35 ± 0.10
1.30 ± 0.10
0.25 min.
Figure 16
9/00
0.25
AL103 Mechanical Dimensions
Reference Only / Allayer Communications
60
AL103 Revision 1.0
9/00
5
4
4
3
3
2
2
1
1
0
0
Reference Only / Allayer Communications
PORT 7/REG. 2C
5
PORT 6/REG. 2A
6
PORT 5/REG. 28
6
PORT 4/REG. 26
7
PORT 3/REG. 24
7
PORT 2/REG. 22
BIT
PORT 1/REG. 20
PORT
PORT 0/REG. 1E
8. Appendix I (VLAN Mapping Worksheet)
61
AL103 Revision 1.0
TRUNK
1
BITS
3, 2
TRUNK
0
BITS
1, 0
9/00
01
4
00
3
11
2
10
1
01
0
00
Reference Only / Allayer Communications
PORT 7/REG. 35
5
PORT 6/REG. 34
10
PORT 5/REG. 33
6
PORT 4/REG. 32
11
PORT 3/REG. 31
7
PORT 2/REG. 30
BIT/
VALUE
PORT 1/REG. 2F
TRUNK
/ PORT
PORT 0/REG. 2E
9. Appendix II (Port to Trunk Port Assignment Work Sheet)
62
AL103 Revision 1.0
10. Appendix III (Suggested Memory Components)
Note: This is only a partial list of memory components that can be used in Allure
devices.
The AL103 uses Frame Buffer SGRAM chips that require 32-bit wide SGRAM or SDRAM, that is
80 MHz or faster with CAS latency 2.
The following lists some of the memory that can be used in the AL103.
9/00
DEVICE
FREQ.
8 Mbit SGRAM
AL103
80 MHz
MoSys - MG802C256Q-10
Etron - EM635327Q-8
16 Mbit SGRAM
MoSys - MG802C512L-8
Etron - EM636327Q-8
Winbond - W971632AF-7
Oki - MS82V16520-7
Reference Only / Allayer Communications
63
AL103 Revision 1.0
Rev. History (Prelim. 1.1 to 1.1a)
1. Reformatted and edited document.
2. Added AL103 overview.
3. Added memory information in appendix III.
4. Added new PHY management timing diagrams.
5. Added new RMII and MII timing diagrams.
Rev. History (Prelim. 1.1a to 1.2)
1. Changed bits 11~15 to reserved in the Miscellaneous Register, Table 29.
2. Revised Queue Management (3.9) section.
Prelim. 1.2 to Rev. 1.0
1. Fully released document.
9/00
Reference Only / Allayer Communications
64
Index
A
Address Aging 19
Address Learning 19
AL103 Interface Block Diagram 15
AL103 Overview 5
AL103 Pin Diagram (Top View) 6
Appendix I (VLAN Mapping Worksheet) 61
Appendix II (Port to Trunk Port Assignment Work Sheet) 62
Appendix III (Suggested Memory Components) 63
B
Broadcast Storm Control 17
MII Interface Port 3 9
MII Interface Port 4 9
MII Interface Port 5 10
MII Interface Port 6 10
MII Interface Port 7 11
MII PHY Management Interface 13
MII Receive Timing 51
MII Transmit Timing 51
Miscellaneous Pins 14
Miscellaneous Register (Register 2D) 46
N
Non Auto-negotiation Mode 29
C
Check Sum (Register 47) 50
O
Other PHY Options 29
D
Data Reception 16
DC Electrical Characteristics 59
P
PHY Management 28
PHY Management (MDIO) Read Timing 52
PHY Management (MDIO) Write Timing 53
PHY Management Master Mode 28
PHY Management MDIO 28
PHY Management Slave Mode 28
Pin Descriptions 7
Port Aggregation 21
Port Based Trunk Load Balancing 22
Port Configuration Register II 44
Port Configuration Registers (Registers 0D to 1C) 43
Port Monitoring 27
Port Monitoring Configuration (Register 06) 43
Port Operation Status Registers (Register 3A to 41) 47
Port Trunk Port Assignment Registers (Registers 2E to 35) 46
Port VLAN Map Registers (Registers 1E to 2C) 45
Power Interface 14
Product Description 1
E
EEPROM Interface 13, 29
EEPROM Map 32
EEPROM Read Cycle 31
EEPROM Start and Stop Bit 30
EEPROM Write Cycle 30
F
False Carrier Events 16
Flow Control 25
Frame Filtering 16
Frame Forwarding 17
Frame Generation 18
Frame Transmission 18
Full Duplex Flow Control (802.3X) 26
Functional Description 16
H
Half Duplex Flow Control (Backpressure) 25
Half Duplex Mode Operation 18
I
Illegal Frame Length 16
Indirect Resource Access Command Register (Register 42) 49
Indirect Resource Access Data I Register (Register 43) 50
Indirect Resource Access Data II Register (Register 44) 50
Indirect Resource Access Data III Register (Register 45) 50
Indirect Resource Access Data IV Register (Register 46) 50
L
Load Balancing 21
Long Frames 16
M
MAC Based Load Balancing Set Up 24
Maximum Ratings 59
Media Independent Interface (MII) 28
MII Interface Port 0 7
MII Interface Port 1 7
MII Interface Port 2 8
Q
Queue Management 26
R
Recommended Operation Conditions 59
Register Tables Summary 36
Reprogramming the EEPROM Configuration 31
Reserved Register (Register 03) 42
Reserved Registers (Registers 07 to 0C) 43
S
Secure Mode Operation 18
SGRAM Interface 12, 36
SGRAM Read Timing 55
SGRAM Refresh Timing 53
SGRAM Write Timing 57
Static Address Entry Format for EEPROM 32
System Block Diagram 1
System Configuration Register I (Register 00) 39
System Configuration Register II (Register 01) 40
System Configuration Register III (Register 02) 41
System Initialization 29
Reference Only / Allayer Communications
AL103 Revision 1.0
System Status Register (Register 39) 47
T
Testing Register (Register 04) 42
Trunk Fail Over 21
Trunk Port Assignment 22
Trunk Port Numbering 22
U
Uplink Port 27
V
Vendor Specific PHY register (Register 05) 42
VLAN Map for an 8 Port Switch 20
VLAN Mapping for Port Based Load Balancing Trunk 23
VLAN Support 19
9/00
Reference Only / Allayer Communications
66