amploc current sensors 805/964-9119 FAX 805/967-8789 AMP50 50 Ampere Rating Box 152, Goleta, CA 93116 e-mail:[email protected] www.amploc.com Hall effect linear sensors. (-40 to +125C) Sensed Current (Amps Fig. peak) 1 50 Sensor Style AMP50 Vs= +5V Vs= +5V ∆Vo at peak rated current * 1.14V Sensitivity mV/A * 23 +Vs 1 Sensor 2 3 Vo Null Offset=Vs/2 Linear to 90A * proportional to Vs Figure 1 +Is AMP50 Magnetic Circuit .83 .36 .51 .16 .36 .29 123 Dimensions: Inches Terminals: .025 sq., 0.1 spacing. Weight: 3 grams. Sense Circuit +Vs Sensed Current 1 2 3 Supply Gnd. Output Caution: Do not reverse supply voltage polarity. ELECTRICAL CHARACTERISTICS + Vo Null Offset= Vs/2 0 -Ip I= Sensed Current (A) +Ip Supply voltage, Vs........................ +4.5 to +10.0Vdc Supply Current................................. 10mA max. Output Current..................................... 2mA max. Offset Voltage, Vo (Sensed Current= 0A.)...Vs/2±2% Output Voltage, Vo is proportional to Vs. Temperature Error Null................... ....................................... .03%/C Gain........................................................ .03%/C Temperature Range..........................-40C to + 125C Response Time.......................................... 3µSec. Linearity (Full Scale).......................................... 1% Accuracy (Full Scale)........................................ ±2% A. C. Hysterisis Error....................................... 0.5%