` AZ692/AZ693 10 AMP MINIATURE POWER RELAY FEATURES Isolation spacing greater than 8mm Dielectric strength 4000 Vrms coil to contact Approvals/Standards include UL, CSA,VDE, IEC, CEE, SEMKO Single pole – Forms A, B and C available 10A switching Life expectancy to 30 million operations Epoxy sealed version for automatic wave soldering and cleaning UL file E44211 ; CSA file LR85091 ; VDE 4120-4940-4002/A1 GENERAL DATA CONTACTS Arrangement SPDT (1 Form C) SPST (1 Form A and 1 Form B) Ratings Resistive load: Max switching power : 300W or 2500VA Max switched current : 10A ; 64A for 2ms Max switched voltage : 150* VDC or 380VAC 10A at 24VDC or 115VAC 0.25HP 120VAC motor load 10A at 250VAC B300 pilot duty UL Rating * If switching voltage is greater than 30VDC, special precautions must be taken. Please consult the factory. Material Silver cadmium oxide Resistance <30 milliohms initially (at rated current, voltage drop method) COIL Power At Pickup Voltage (typical) Standard coil 337mW Sensitive coil 234mW Max Continuous Dissipation 1.9W at 20°C ambient 1.4W at 40°C ambient Temperature Rise Standard 40°C at nominal coil voltage Sensitive 26°C at nominal coil voltage Max Temperature 110°C Life Expectancy Mechanical Electrical Minimum operations 30 million operations 1x105 at 10A, 30VDC or 115VAC 2x105 at 8A, 250VAC Operate Time (typical) 6ms at nominal coil voltage Release Time (typical) 2ms at nominal coil voltage (with no coil suppression) Dielectric Strength (at sea level for 1 min) 4000 Vrms coil to contact 1000 Vrms between open contacts Insulation Resistance 10,000 megohms min at 500VDC, 20°C, 50% RH Dropout Greater than 10% of nominal coil voltage Ambient Temperature Operating Storage At nominal coil voltage Standard -55°C to 70C Sensitive -55°C to 80C Both -55°C to 110C Vibration 0.062” DA at 10 – 55 Hz Shock 20g Enclosure PBT Polyester Terminals Tinned copper alloy, PC Weight 17 grammes NOTES 1. All values at 20°C 2. Relay may pull in with less than ‘Must Operate’ value 3. PCB layout viewed towards terminals 4. Specifications subject to change without notice 5. Unsealed relays should not be dip cleaned Logistic Design (UK) Limited Unit 3 Eagle Centre Way, Sedgwick Road Luton LU4 9US, United Kingdom Tel +44 (0)1582 599 600 Fax +44 (0)1582 599 700 www.zettlerrelay.com [email protected] LDZR201000