ETC S322

Series 3
3 Amp • 120, 240 Vac • AC Output
work (S3 types), Series 3 is an ideal
replacement for power reed relays in
microprocessor or computer-based logic
level systems. Designed for long, reliable service in a multitude of demand• UL, CSA, VDE Approved
ing industrial environments.
Manufactured in Crydom's ISO 9001
These solid state relays combine small Certified facility for optimum product
size and high ratings in a PC-board- performance and reliability.
mounted SPST-NO design. Available
with (S30 types) or without snubber net-
• Compact for High
Density PCB M ount
• Small Footprint
CURRENT DERATING CURVE
Load Current [Amps]
4
MODEL NO.
INPUT SPECIFICATIONS ➀
S312
S3012A
S322
S3022A
Control Voltage Range
3.5-8 Vdc
3.5-8 Vdc
Nominal Input Impedance
200 Ohm
200 Ohm
Typical Input Current @ 5 Vdc
20 mAdc
20 mAdc
3
2
Must Turn On Voltage
3.5 Vdc
3.5 Vdc
1
Must Turn Off Voltage
1.0 Vdc
1.0 Vdc
0
Operating Voltage Range (47-63 Hz)
OUTPUT SPECIFICATIONS ➀
20
40
60
80
Ambient Temperature [˚ûC]
Max Load Current vs. Temperature
S3
Package
.45
.68 (11.4)
(17.3)
1
INPUT
LOAD
2
.80 .60
(20.3) (15.2)
3
+
BOTTOM
VIEW
4
.10
(2.5)
.70
(17.8)
.80
(20.3)
1.20
(30.5)
.10
(2.5)
.15-3.0
INPUT
LOAD
3
+
.025 x .025
TERMINAL PIN
(4 PLACES)
BOTTOM
VIEW
4
.70
(17.8)
.80
(20.3)
1.45
(36.8)
All dimensions are in inches (millimeters)
APPROVALS
UL
E116949
CSA LR81689
VDE 10114 UG
FastFax Document No. 117
SERIES 3
Rev. 042302
PAGE 1 OF 1
.15-3.0
600 Vpk
600 Vpk
Max. Surge Current, (16.6ms)
55 Apk
55 Apk
200 V/µsec
200 V/µsec
➂
1.0 mA
Max.Off-State Leakage @ Rated Voltage
4.0 mA
1.0 mA
4.0 mA
Max. On-State Voltage Drop @ Rated Current
1.5 Vpk
1.5 Vpk
Max.Turn-On Time
1/2 cycle
1/2 cycle
Max. Turn-Off TIme
1/2 cycle
1/2 cycle
0.5
0.5
Dielectric Strength
➁
4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc
➁
109 Ohm
8.0 pF
Max. Capacitance
1
.15-3.0
GENERAL SPECIFICATIONS
S30
Package
2
40-280 Vrms
Transient Over-Voltage
Power Factor (Min.) WIth Max. Load
.70
.87 (17.8)
(22.1)
.60
.80 (15.2)
(20.3)
.15-3.0
Load Current Range (Arms)
Min. Off-State dv/dt @ Max. Rated Voltage
.025 x .025
TERMINAL PIN
(4 PLACES)
20-140 Vrms
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-30 to 125˚C
M ECHANICAL SPECIFICATIONS
0.6 oz. (0.8 g)
Weight: (typical)
Encapsulation:
GENERAL NOTES
➀
➁
➂
Thermally Conductive Epoxy
©2002 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚C unless otherwise specified.
Dielectric and insulation resistance are measured between input and output.
Off-State dv/dt test method per EIA/NARM standard RS-443.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506