Series 3
•
•
•
•
Output rated at 3A @ 20-280 VAC
DC control
Zero-crossing (resistive loads) output
Compact design ideal for replacing electromechanical relays
PRODUCT SELECTION
Control Voltage
120 VAC
240 VAC
S312
S3012A
S322
S3022A
3.5-8 VDC
3.5-8 VDC
OUTPUT SPECIFICATIONS (1)
Description
S312
S3012A
S322
S3022A
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Minimum Power Factor (with Maximum Load)
20-140
600
1
200
3
0.15
55
1.5
0.5
20-140
600
4
201
3
0.15
55
1.5
0.5
40-280
600
1
200
3
0.15
55
1.5
0.5
40-280
600
4
200
3
0.15
55
1.5
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Maximum Turn-On Voltage
Minimum Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ 5 VDC
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
3.5-8 VDC
3.5 VDC
1.0 VDC
200 Ohm
20 mA
1/2 Cycle
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
Minimum Insulation Resistance (@ 500 V DC)(2)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
4000 Vrms
109 Ohm
8.0 pF
-30 to 80°C
-30 to 125 °C
0.6 oz (0.8g)
Thermally conductive
Epoxy
GENERAL NOTES
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Dielectric and insulation resistance are measured between input and output
3) Off-State dv/dt test method per EIA/NARM standard RS-443,
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
UL E116949
CSA LR81689
VDE 10114 UG
Rev. 120210