Series DO, DMO 1-3.0 Amp • 60 Vdc • DC Output MINI-SIP • Compact for High Density PCB M ount • DC Control, DC Output SPST-NO DC output relays in epoxycoated packages utilize the popular .10" grid lead spacing. They are available with either bipolar transistor output (DO), or the DMO063 with MOSFET output rated at 3A/60 VDC. • Bipolar (DO) or M OSFET (DM O) Output Manufactured in Crydom's ISO 9002 Certified facility for optimum product performance and reliability. • 3-10 Vdc Logic Compatible Input • Crydom's Patented Design LOAD CURRENT (AMPS) CURRENT DERATING CURVES DO061A➃ DO061B➃ DM O063➃ 3.0-9.0 Vdc 1.7-9.0 Vdc 3.0-10.0 Vdc Nominal Input Impedance 270 Ohm 270 Ohm 200 Ohm Typical Input Current @ 5 Vdc 15 mAdc 15 mAdc 20 mAdc MODEL NO. INPUT SPECIFICATIONS ➀ Control Voltage Range 1.0 0.8 0.6 0.4 Must Turn On Voltage 3.0 Vdc 1.7 Vdc 3.0 Vdc 0.2 Must Turn Off Voltage 1.0 Vdc 0.8 Vdc 1.0 Vdc 3-60 Vdc 3-60 Vdc 0-60 Vdc 0 20 40 60 80 OUTPUT SPECIFICATIONS ➀ Operating Voltage Range AMBIENT TEMPERATURE (¼C) DO Max. Load Current vs. Temp. .02-1.0 Adc Load Current Range LOAD CURRENT (AMPS) 3 Max. Surge Current Max.Off-State Leakage @ Rated Voltage 2 0 20 40 60 80 AMBIENT TEMPERATURE (¼C) DMO Max. Load Current vs. Temp. 12.0 Adc(10 ms) 200 µAdc 100 µAdc 1.5 Vdc 0.4 Vdc ➁ Max.Turn-On Time 50 µsec 50 µsec 50 µsec Max. Turn-Off TIme 50 µsec 150 µsec 300 µsec GENERAL SPECIFICATIONS Dielectric Strength ➂ Insulation Resistance (Min.) @ 500 Vdc DO .950 (24.1) .400 (10.2) MAX. DMO .200 (5.1) .500 (12.7) 1 ➂ Max. Capacitance (Input/Output) 4000 Vrms 109 Ohm 2500 Vrms 109 Ohm 8.0 pF 8.0 pF Ambient Operating Temperature Range -30 to 80˚C -30 to 80˚C Ambient Storage Temperature Range -30 to 125˚C -30 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 0.15 oz. (4.3 g) CONTROL LOAD .030 (0.8) 5.0 Adc (1 Sec) Max. On-State Voltage Drop @ Rated Current 1 0-3.0 Adc 2 3 .250 (6.3) 4 .100 (2.5) .500 (12.7) .700 (17.8) FastFax Document No. 104 SERIES DO, DMO Rev. 021202 PAGE 1 OF 1 Encapsulation: GENERAL NOTES .015 (0.4) PIN PIN PIN PIN .015 (0.4) 1: 2: 3: 4: +DC LOAD -DC LOAD +DC CONTROL -DC CONTROL ➀ ➁ ➂ ➃ Thermally Conductive Epoxy ©2002 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25˚C unless otherwise specified. Typical On-State Resistance = .13 Dielectric and insulation resistance are measured between input and output. Inductive loads should be diode suppressed. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506