HCX...A6 / HCX(M)...D6 - Series Fully signal conditioned pressure transducer FEATURES · Pressure ranges from ±5 mbar to 5 bar differential, 1 and 2 bar absolute · TTL power supply · 0.5 to 4.5 V output · Inline pinning for easy PCB-mounting · Externally adjustable offset and span SERVICE Non-corrosive, non-ionic working fluids, such as dry air and dry gases. Output current Source Sink Temperature limits Operating Storage Compensated Humidity Proof pressure1 HCXP...M005, HCX...M010 HCXM050 to HCXM350 all HCX... 1cm 1 inch ELECTRICAL CONNECTION SPECIFICATIONS Maximum ratings Excitation voltage Scale: 4.8 V to 15 V 10 mA 10 mA -20°C to 70°C -20°C to 85°C 0°C to 50°C 0 - 95 %RH 350 mbar 1.4 bar 2 x rated pressure January 1998/026 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com HCX...A6 / HCX(M)...D6 - Series Fully signal conditioned pressure transducer PERFORMANCE CHARACTERISTICS Ω, tamb = 25°C) (unless otherwise noted, VS = 5 V, RL > 100 kΩ Characteristics Min. Operating pressure HCXPM005D6... HCXM010D6... HCXPM010D6... HCXM020D6... HCXM050D6... HCXM100D6... HCXM350D6... HCX001...6... HCX002...6... HCX005...6... Zero pressure offset all HCXPM... HCXM010D6/HCXM020D6... all other devices Span5 Full scale output Output at lowest specified pressure HCXPM... only HCXM020D6... Non-linearity and hysteresis (BSL)2 all other devices Thermal effects (0 to 50°C)4 Combined offset and span HCXP...M005D6... HCXM010D6... to HCXM050D6... HCXM100D6... all other devices Output impedance Long term stability3 Power supply rejection Offset Span Power consumption -5 0 -10 0 0 0 0 0 0 0 2.40 0.40 0.45 3.95 Typ. 2.50 0.50 0.5 4.0 4.5 0.5 0.5 0.1 Max. 5 10 10 20 50 100 350 1000 2000 5000 2.60 0.60 0.55 4.05 1.0 0.5 0.20 0.12 0.10 0.05 50 ±0.2 0.05 0.03 50 Unit mbar V %FSO %FSO/°C Ω %FSO %FSO/V mW OUTLINE DRAWING HCX(M)...6H, HCXPM...6H P1: P2: High pressure port for 5 mbar and 10 mbar devices High pressure port for all other devices. Mass: 14 g January 1998/026 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com HCX...A6 / HCX(M)...D6 - Series Fully signal conditioned pressure transducer OUTLINE DRAWING HCX(M)...6V P1: P2: High pressure port for 5 mbar and 10 mbar devices High pressure port for all other devices. Mass: 14 g All dimensions in mm ORDERING INFORMATION Part Number Package version Pressure range Differential / gage devices 0 to ±5 mbar 0 to 10 mbar 0 to ±10 mbar 0 to 20 mbar 0 to 50 mbar 0 to 100 mbar 0 to 350 mbar 0 to 1 bar 0 to 2 bar 0 to 5 bar Absolute devices 0 to 1 bar 0 to 2 bar Side facing ports Top facing ports HCXPM005D6V HCXM010D6V HCXPM010D6V HCXM020D6V HCXM050D6V HCXM100D6V HCXM350D6V HCX001D6V HCX002D6V HCX005D6V HCXPM005D6H HCXM010D6H HCXPM010D6H HCXM020D6H HCXM050D6H HCXM100D6H HCXM350D6H HCX001D6H HCX002D6H HCX005D6H HCX001A6V HCX002A6V HCX001A6H HCX002A6H Specification Notes 1. 2. 3. 4. 5. 6. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full scale pressure). Change after one year or 1 million pressure cycles. Thermal effects tested and guaranteed from 0°C to 50°C relative to 25°C. All specifications shown are relative to 25°C. Span is the algebraic difference between the output at full scale pressure and offset. Offset adjustment possible to lower values only. Do not trim for nominal value minus 150 mV. Span adjustment possible to lower pressure range (higher gain). Do not trim for more than 15% of full scale pressure Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. January 1998/026 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com