ETC SCP-5144

tSENSITRON
SCP-5144
SEMICONDUCTOR
TECHNICAL DATA
PART NUMBER: SCP-5144, ENG. -
3-Phase Bridge -- IGBT Module
600V, 100A
Features:
• Multiple Layer, Moisture and Contamination Resistant
Construction
• Increased Creepage and Clearance Distances for High Altitude
Operation
• Operation at Temperature Extremes
• Internal Layout with Minimized Stray Inductances
• High Frequency Switching
All ratings are at T A = 25oC unless otherwise specified.
Maximum Ratings
Symbol
Vces
Ic
Icpulse
VGE
Hipot
Tj
Diode
IF
IFM
Test Conditions
Tj = 150C
Tc = 25C / 80C
Tc = 25C / 80C
F= 10kHz, D=.05, Vce = 300V
1500Vrms, 50Hz / 60Hz, 1 min.
Tc = 25C / 80C
Tc = 25C / 80C
F= 10kHz, D=.05
Value
600
100 / 70
200 / 140
Units
+ / - 20
V
A
A
10
V
uA
-55 to 150
°C
100 / 70
200 / 140
A
A
Electrical Characteristics
All ratings are at TA = 25oC unless otherwise specified.
Symbol
Test Conditions
Min.
Typ.
Max.
Units
V(BR)ces
Vge = 0V,
600
V
VCE(sat)
Vge = 15V, Ic = 100A
2.0
V
VGE(th)
Ic = 1mA, Vge = Vce
5.5
V
ICES
Vce = 600V, Vge = 0V
mA
IGES
Vce = 0V , Vge = 20V
250
nA
Ciss
Vce = 25V
5
nF
Vge
=
0V
Coss
1.5
nF
f = 1MHz
Crss
.4
nF
td(on)
Vc = 300V
50
ns
tr
Ic = 100A
20
ns
Vge = + / - 15V
td(off)
150
ns
Rg = 2.7 Ohm
tf
30
ns
Diode
VF
trr
IF = 100A, F= 10kHz, D=.05
Vr = 300V
1.6
200
V
ns
• 221 West Industry Court 3 Deer Park, NY 11729-4681 3 Phone (631) 586 7600 Fax (631) 242 9798 •
• World Wide Web - http://www.sensitron.com • E-Mail Address - [email protected] •
SCP-5144
SENSITRON
TECHNICAL DATA
PART NUMBER: SCP-5144, ENG. MECHANICAL DIMENSIONS: In Inches / mm
SCHEMATIC
(+)
G1
G3
G5
E1
E3
E5
(~ )1
( ~)2
G2
G4
G6
E2
E4
E6
(~)3
(-)
• 221 West Industry Court 3 Deer Park, NY 11729-4681 3 Phone (631) 586 7600 Fax (631) 242 9798 •
• World Wide Web - http://www.sensitron.com • E-Mail Address - [email protected] •
SENSITRON
SEMICONDUCTOR
TECHNICAL DATA
DISCLAIMER:
1- The information given herein, including the specifications and dimensions, is subject to change without prior notice to improve product
characteristics. Before ordering, purchasers are advised to contact the Sensitron Semiconductor sales department for the latest version
of the datasheet(s).
2- In cases where extremely high reliability is required (such as use in nuclear power control, aerospace and aviation, traffic equipment,
medical equipment, and safety equipment), safety should be ensured by using semiconductor devices that feature assured safety or by
means of users’ fail-safe precautions or other arrangement.
3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during
operation of the user’s units according to the datasheet(s). Sensitron Semiconductor assumes no responsibility for any intellectual
property claims or any other problems that may result from applications of information, products or circuits described in the datasheets.
4- In no event shall Sensitron Semiconductor be liable for any failure in a semiconductor device or any secondary damage resulting from
use at a value exceeding the absolute maximum rating.
5- No license is granted by the datasheet(s) under any patents or other rights of any third party or Sensitron Semiconductor.
6- The datasheet(s) may not be reproduced or duplicated, in any form, in whole or part, without the expressed written permission of
Sensitron Semiconductor.
7- The products (technologies) described in the datasheet(s) are not to be provided to any party whose purpose in their application will
hinder maintenance of international peace and safety nor are they to be applied to that purpose by their direct purchasers or any third
party. When exporting these products (technologies), the necessary procedures are to be taken in accordance with related laws and
regulations.
• 221 West Industry Court Deer Park, NY 11729-4681 (631) 586-7600 FAX (631) 242-9798 •
• World Wide Web - http://www.sensitron.com • E-Mail Address - [email protected]