APPLICATION
Instrumentation and computer cable for EIA RS-485 data transmission applications.
CONSTRUCTION
1
2
3
7
4
5
6
1.
Conductor
AWG24 (7xAWG32) tinned Cu
2.
Insulation
Material
Diameter over insulation
Colour of insulation
Polyethylene
1.73 ± 0.05 mm
White/blue and blue/white
Filler (2x)
Material
Diameter
Colour
Polypropylene
1.90 mm
White
Foil (Beldfoil®)
Material
Thickness
Aluminium / Polyester
9 / 23 µm
5.
Drainwire
AWG24 (7xAWG32) tinned Cu
6.
Braiding
Material
Coverage
0.122 mm tinned Cu
90%
Sheath
Material
Colour
Nominal thickness
Nominal diameter
FRNC (UV stabilised)
Chrome (like RAL 7037)
0.89 mm
5.90 mm
3.
4.
7.
 Belden Wire & Cable B.V.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
TECHNICAL DATA SHEET
9841NH
REQUIREMENTS AND TEST METHODS
Electrical:
Nominal resistance conductor
Nominal resistance shield
Nominal capacitance conductor to conductor
Nominal capacitance conductor to shield + other cond.
Nominal impedance @ 1 MHz
Nominal velocity of propagation
Nominal delay
Nominal attenuation @ 1 MHz
Testvoltage conductor-conductor
Testvoltage conductor-screen
Voltage rating
Maximum continues current per conductor @ 25 °C
Mechanical and physical:
Flame resistance
Oil resistance
Radiation resistance
Application specification
Halogen content according to IEC754-1
Corrosivity of fire gasses according to IEC754-2
Conductivity
pH value
Temperature range installing
Temperature range operating (moving installation)
Temperature range operating (fixed installation)
Temperature range storage
Minimum bending radius
Maximum pulling tension
code
version
date
page
9841NH
7
2010-02-22
2/2
78.7 Ω/km
11.0 Ω/km
42.0 pF/m
75.5 pF/m
120 Ω
66 %
5.2 ns/m
1.97 dB/100m
2500 VDC, 3 seconds
2500 VDC, 3 seconds
300 V RMS (CM application)
30 V RMS (AWM application)
2.1 A
IEC 60332-3C
ASTMD741
IEC544 (CERN)
BS 7655 section 6.1 table 1, LTS 3
zero
≤ 100 µS/cm
≥ 3.5
-15 to +80 ˚C
-15 to +80 ˚C
-45 to +80 ˚C
-45 to +80 ˚C
10 x cable diameter
328 N
PACKAGING
On non-returnable reels with a nominal length of 305m (-0, +10%) or on non-returnable reels
with a nominal length of 500m (-0, +10%) or on non-returnable reels with a nominal length of
1000m (-0, +10%).
Each reel is labelled with the following data:
Belden Logo. Belden code number. Item description. Length on the reel. Date of manufacture.
CE-marking.
Belden declares this product to be in compliance with the environmental regulations EU RoHS (Directive 2002/95/EC, 27
January 2003); this is valid for all material produced after the RoHS compliant date for this product.
 Belden Wire & Cable B.V.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner