ETC MPMB62D

MPMB62D-68KX3
256MB PC-2700 DDR DIMM
MPMB62D-68KX3 PC-2700 CL2.5 184pin DDR DIMM
32Mx64 DDR DIMM based on 16Mx8 DDR SDRAMs with SPD
DESCRIPTION
The MPMB62D-68KX3 is 32M bit x 64 Double Data Rate Synchronous Dynamic RAM
high density memory module based on 128Mb DDR SDRAM respectively.
The MPMB62D-68KX3 consists of sixteen CMOS 16M × 8 bit with 4 banks Double
Data Rate Synchronous DRAMs in TinyBGA package and a 2K EEPROM in 8-Pin TSSOP
package mounted on a 184pin glass-epoxy substrate. Two 0.1µF decoupling capacitors are
mounted on the printed circuit board in parallel for each DDR SDRAM.
The MPMB62D-68KX3 is a Dual In- line Memory Module and is intended for mounting
into 184pin edge connector sockets.
Synchronous design allows precise cycle control with the use of system clock. Data I/O
transactions are possible on both edges of every clock cycle. Range of operating frequencies,
programmable latencies and burst lengths allows the same device to be useful for a variety of
high bandwidth, high performance memory system applications.
FEATURES
• Performance range - 166MHz ( DDR333, CL2.5 )
• Double-data-rate architecture; two data transfers per clock cycle
• Bi-directional data strobe (DQS)
• Differential clock inputs (CK and /CK)
• DLL aligns DQ and DQS transition with CK transition
• Auto & self refresh capability (4096 Cycles / 64ms)
• Single 2.5V ±0.2V power supply
• Programmable Read latency 2, 2.5 (clock)
• Programmable Burst length (2, 4, 8)
• Programmable Burst type (Sequential & Interleave)
• Edge aligned data output, center aligned data input
• Serial presence detect with EEPROM
• PCB : Height (1,181 mil), double sided component
Kingmax - Memory Module
1
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
PIN CONFIGURATIONS (Front side/Back side)
Pin
Front
Pin
Front
Pin
Back
Pin
Back
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
VREF
DQ0
VSS
DQ1
DQS0
DQ2
VDD
DQ3
NC
NC
VSS
DQ8
DQ9
DQS1
VDDQ
CK1
/CK1
VSS
DQ10
DQ11
CKE0
VDDQ
DQ16
DQ17
DQS2
VSS
A9
DQ18
A7
VDDQ
DQ19
A5
DQ24
VSS
DQ25
DQS3
A4
VDD
DQ26
DQ27
A2
VSS
A1
*CB0
*CB1
VDD
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
*DQS8
A0
*CB2
VSS
*CB3
BA1
DQ32
VDDQ
DQ33
DQS4
DQ34
VSS
BA0
DQ35
DQ40
VDDQ
/ME
DQ41
/CAS
VSS
DQS5
DQ42
DQ43
VDD
NC
DQ48
DQ49
VSS
/CK2
CK2
VDDQ
DQS6
DQ50
DQ51
VSS
VDDID
DQ56
DQ57
VDD
DQS7
DQ58
DQ59
VSS
WP
SDA
SCL
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
VSS
DQ4
DQ5
VDDQ
DM0
DQ6
DQ7
VSS
NC
NC
*A13
VDDQ
DQ12
DQ13
DM1
VDD
DQ14
DQ15
CKE1
CDDQ
*BA2
DQ20
*A12
VSS
DQ21
A11
DM2
VDD
DQ22
A8
DQ23
VSS
A6
DQ28
DQ29
VDDQ
DM3
A3
DQ30
VSS
DQ31
*CB4
*CB5
VDDQ
CK0
/CK0
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
VSS
*DM8
A10
*CB6
VDDQ
*CB7
VSS
DQ36
DQ37
VDD
DM4
DQ38
DQ39
VSS
DQ44
/RAS
DQ45
CDDQ
/CS0
/CS1
DM5
VSS
DQ46
DQ47
NC
VDDQ
DQ52
DQ53
NC
VDD
DM6
DQ54
DQ55
VDDQ
NC
DQ60
DQ61
VSS
DM7
DQ62
DQ63
VDDQ
SA0
SA1
SA2
VDDSPD
PIN NAME
Pin Name
A0 ~ A11
BA0 , BA1
DQ0 ~ DQ63
DQS0 ~ DQS7
CK0 ~ CK2
/CK0 ~ /CK2
CKE0 , CKE1
/CS0 , /CS1
/RAS
/CAS
/WE
DM0 ~ DM7
VDD
VDDQ
VSS
VREF
VDDSPD
SDA
SCL
SA0 ~ SA2
VDDID
NC
Function
Address input (Multiplexed)
Select bank Address
Data input/output
Data Strobe input/output
Clock input
Clock input
Clock enable input
Chip select input
Row address strobe
Column address strobe
Write enable
Data-in mask
Power supply (2.5V)
Power supply for DQS (2.5V)
Ground
Power supply for reference
Serial EEPROM power
supply (2.5V~6V)
Serial data I/O
Serial clock
Address in EEPROM
VDD identification flag
No connection
* These pins are not used in this module.
Kingmax - Memory Module
2
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
FUNCTIONAL BLOCK DIAGRAM
CLK1
DQS0
DM0
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
DQS1
DM1
DQ8
DQ9
DQ10
DQ11
DQ12
DQ13
DQ14
DQ15
DQS2
DM2
DQ16
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
CLK2
120 W
/CLK1
/CS1
/CS0
22W x 10
22W x 10
22W x 10
/CLK /CS CLK
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
U1
/CLK /CS CLK
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
U2
DQS6
DM6
DQ48
DQ49
DQ50
DQ51
DQ52
DQ53
DQ54
DQ55
U10
/CLK /CS CLK
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
U3
DQS5
DM5
DQ40
DQ41
DQ42
DQ43
DQ44
DQ45
DQ46
DQ47
U9
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
120 W
/CLK2
DQS7
DM7
DQ56
DQ57
DQ58
DQ59
DQ60
DQ61
DQ62
DQ63
U11
22W x 10
22W x 10
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U6
DQ3
DQ4
DQ5
DQ6
DQ7
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U14
DQ3
DQ4
DQ5
DQ6
DQ7
/CLK /CS CLK
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U15
DQ3
DQ4
DQ5
DQ6
DQ7
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
U7
/CLK /CS CLK
22W x 10
DQS
DM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U16
DQ3
DQ4
DQ5
DQ6
DQ7
U8
CLK0
120 W
/CLK0
DQS3
DM3
DQ24
DQ25
DQ26
DQ27
DQ28
DQ29
DQ30
DQ31
22W x 10
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U4
DQ3
DQ4
DQ5
DQ6
DQ7
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U12
DQ3
DQ4
DQ5
DQ6
DQ7
DQS4
DM4
DQ32
DQ33
DQ34
DQ35
DQ36
DQ37
DQ38
DQ39
A0 ~ A11,BA0,BA1
/RAS, /CAS, /WE
CKE0
CKE1
VDD
One 0.1uF capacitor
per each SDRAM
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U5
DQ3
DQ4
DQ5
DQ6
DQ7
22W x 10
To SDRAM U1 ~ U16
VSS
/CLK /CS CLK
DQS
DM
DQ0
DQ1
DQ2
U13
DQ3
DQ4
DQ5
DQ6
DQ7
SDRAM
SDRAM
SDRAM
SDRAM
U1 ~ U16
U1 ~ U16
U1 ~ U8
U9 ~ U16
VDDSPD
Serial PD
SCL
SCL
WP
SDA
A0 A1 A2
SDA
VDD
VREF
One 0.1uF capacitor
per each SDRAM
To SDRAM U1 ~ U8
VSS
SA0 SA1 SA2
Kingmax - Memory Module
3
March 2002
Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
ABSOLUTE MAXIMUM RATIINGS
Parameter
Symbol
Value
Unit
Supply voltage relative to VSS
VDD
-1.0 ~ 3.6
V
I/O pins voltage relative to VSS
VIN, VOUT
-0.5 ~ 3.6
V
TA
0 ~ +70
°C
TSTG
-55 ~ +125
°C
PD
16
W
Operating temperature
Storage temperature
Power dissipation
Note: Permanent device damage may occur if
“ABSOLUTE MAXIMUM RANTINGS” are
exceeded. Functional operation should be restricted to recommended operating condition.
Exposure to higher than recommended voltage for extended periods of time affect device
reliability.
DC OPERATING CONDITIONS AND CHARACTERISTIICS (SSTL_2 In/Out)
Recommended operating conditions (TA = 0 to 70°C, VDD = +2.5V ±0.2V)
Parameter
Symbol
Min
Max
Unit
Note
Supply Voltage
VDD
2.3
2.7
V
I/O Reference voltage
VREF
0.49×VDD
0.51×VDD
V
1
I/O Termination voltage (system)
VTT
VREF-0.04
VREF+0.04
V
2
Input logic high voltage
VIH(DC)
VREF+0.15
VDD +0.3
V
3
Input logic low voltage
VIL(DC)
-0.3
VREF-0.15
V
3
Input voltage level, CK and /CK inputs
VIN(DC)
-0.3
VDD +0.3
V
Input differential voltage, CK and /CK inputs
VID(DC)
0.3
VDD +0.6
V
Output high current (VOUT = 1.95V)
IOH
16.8
-
mA
Output low current (VOUT = 0.35V)
IOL
-16.8
-
mA
Input leakage current
II
-16
16
µA
5
Output leakage current
IOZ
-40
40
µA
6
4
Note : 1. VREF is expected to be equal to 0.5×VDD of the transmitting devices, and must track
variations in the DC level of the same. Peak-to-peak noise on VREF, may not exceed 2% of
the DC value.
2. VTT is not applied directly to the device. VTT is a system supply for signal termination
resistors, is expected to be set equal to VREF, and must track variations in the DC level of
VREF.
3. These parameters should be tested at the pin on actual components. The AC and DC input
specifications are relative to a VREF envelop that has been bandwidth limited to 200MHz.
4. VID is the magnitude of the difference between the input level on CK and the input on /CK.
5. Any input 0V ≤ VIN ≤ VDD , VREF pin 0V ≤ VIN ≤ 1.35V, All other pins not under test = 0 V
6. 0V ≤ VOUT ≤ VDD , DQs are disabled.
Kingmax - Memory Module
4
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
IDD CONDITIONS AND SPECIFICATIONS
Recommended operating conditions unless otherwise noted, TA = 0 to 70°C, VDD = +2.5V ±0.2V
Parameter / Condition
Symbol Max
Unit Note
Operating current - One bank; Active-Precharge;
tRC = tRC(Min); tCK = tCK(Min); DQ, DM and DQS inputs
changing twice per clock cycle; Address and control inputs
changing once per clock cycle
IDD0
1080
mA
Operating current - One bank; Active-Read-Precharge;
Burst = 2; tRC = tRC(Min); tCK = tCK(Min); IOUT = 0 mA;
Address and control inputs changing once per clock cycle
IDD1
1520
mA
Precharge power-down standby current; All banks idle;
Power-down Mode; tCK = tCK(Min); CKE = LOW
IDD2P
520
mA
Idle standby current; /CS = HIGH; All banks idle;
tCK = tCK(Min); CKE = HIGH; Address and control inputs
changing once per clock cycle; VIN = VREF for DQ, DQS and DM
IDD2F
680
mA
Active power-down standby current; One banks active;
Power-down Mode; tCK = tCK(Min); CKE = LOW
IDD3P
560
mA
Active standby current; /CS = HIGH; CKE = HIGH; One bank;
Active-Precharge; tRC = tRAS(Max); tCK = tCK(Min) ; DQ,
DM and DQS inputs changing twice per clock cycle; Address and
other control inputs changing once pre clock cycles
IDD3N
680
mA
Operating current; Burst = 2; Reads; Continuous burst;
One bank active; Address and control inputs changing once per
clock cycle; tCK = tCK(Min); IOUT = 0 mA
IDD4R
1640
mA
Operating current; Burst = 2; Writes; Continuous burst;
One bank active; Address and control inputs changing once per
clock cycle; tCK = tCK(Min); DQ, DM and DQS inputs changing
twice per clock cycle
IDD4W
1520
mA
Auto refresh current; tRC = tRC(Min); distributed refresh
IDD5
1960
mA
Self refresh current; CKE ≤ 0.2V; External clock should be on
IDD6
80
mA
Operating current; Four bank interleaving READs with BL = 4;
Auto Precharge; tRC = tRC(min); tCK = tCK(min); Address and
control inputs change only Active READ or WRITE commands
IDD7
2560
mA
Kingmax - Memory Module
5
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
AC INPUT OPERATING CONDITIONS
Recommended operating conditions (TA = 0 to 70°C, VDD = +2.5V ±0.2V)
Parameter / Condition
Symbol
Min
Max
Input logic high voltage
VIH(AC)
VREF+0.31
-
V
1
Input logic low voltage
VIL(AC)
-
VREF-0.31
V
1
Input differential voltage, CK and /CK inputs
VID(DC)
0.7
VDD +0.6
V
2
Input crossing point voltage, CK and /CK inputs
VIX(DC)
V
3
0.5×VDD -0.2 0.5×VDD +0.2
Unit Note
Note : 1. These parameters should be tested at the pin on actual components. The AC and DC input
specific ations are relative to a VREF envelop that has been bandwidth limited to 200MHz.
2. VID is the magnitude of the difference between the input level on CK and the input on /CK.
3. The value of VIX is expected to be equal 0.5×VDD of the transmitting device and must track
variations in the DC level of the same.
AC OPERATING TEST CONDITIONS (TA = 0 to 70°C, VDD = +2.5V ±0.2V)
Parameter
Value
Input reference voltage for Clock
Input signal maximum peak swing
Input signal minimum slew rate
Input Levels(VIH /VIL )
Input timing measurement reference level
Output timing measurement reference level
Output load condition
0.5×VDD
1.5
1.0
VREF+0.31 / VREF-0.31
VREF
Vtt
See Load Circuit
Unit
V
V
V
V
V
V
Output Load Circuit (SSTL_2)
Kingmax - Memory Module
6
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
AC TIMMING PARAMETERS AND SPECIFICATIONS
(These AC characteristics were tested on the component)
Parameter
Symbol
Min
Row cycle time
tRC
Max
Refresh row cycle time
Row active time
tRFC
tRAS
60
72
42
/RAS to /CAS delay
tRCD
18
ns
tRP
18
ns
5
Row active to Row active delay
tRRD
12
ns
5
Write recovery time
tWR
2.5
tCK
Last data in to Read command
tCDLR
1
tCK
Col. address to Col. address delay
tCCD
1
tCK
Row precharge time
ns
ns
ns
tCH
tCL
tDQSCK
tAC
tDQSQ
tRPRE
7.5
6.0
0.45
0.45
-0.6
-0.7
0.9
12
12
0.55
0.55
+0.6
+0.7
+0.35
1.1
tCK
tCK
ns
ns
ns
tCK
Read Post amble
tRPST
0.4
0.6
tCK
CK to valid DQS-in
tDQSS
0.75
1.25
tCK
DQS-in setup time
tWPRES
0
ns
DQS-in hold time
tWPREH
0.25
tCK
DQS falling edge to CK rising-setup time
tDSS
0.2
tCK
DQS falling edge from CK rising-hold time
tDSH
0.2
tCK
DQS-in high level width
tDQSH
0.35
tCK
DQS-in low level width
tDQSL
0.35
tCK
tDSC
0.9
Address and Control Input setup time
tIS
0.75
ns
6
Address and Control Input hold time
tIH
ns
6
Data-out high impedance time from CK, /CK
tHZ
Data-out low impedance time from CK, /CK
tLZ
tSL(I)
0.75
tACmin
- 400ps
tACmin
- 400ps
0.5
Input Slew Rate (for I/O pins)
tSL(IO)
0.5
Output Slew Rate (x8)
tSL(O)
1.0
4.5
Output Slew Rate Matching Ratio (rise to fall)
tSLMR
0.67
1.5
Clock cycle time
CL = 2.0
CL = 2.5
70K
Unit Note
Clock high level width
Clock low level width
DQS-out access time from CK, /CK
Output data access time from CK, /CK
Data strobe edge to output data edge
Read Preamble
DQS-in cycle time
Input Slew Rate (for input only pins)
Kingmax - Memory Module
tCK
7
1.1
tACmax
- 400ps
tACmax
- 400ps
ns
5
2
tCK
ps
ps
V/ns
6
V/ns
7
V/ns
10
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
Parameter
Symbol
Min
tMRD
12
ns
DQ & DM setup time to DQS
tDS
0.45
ns
7,8,9
DQ & DM hold time to DQS
tDH
0.45
ns
7,8,9
DQ & DM input pulse width
tDIPW
1.75
ns
Power down exit time
tPDEX
10
ns
Exit self refresh to write command
tXSW
95
ns
Exit self refresh to bank active command
tXSA
75
ns
Exit self refresh to read command
tXSR
200
Cycle
Refresh interval time
tREF
15.6
us
1
Output DQS valid window
tQH
ns
5
Clock half period
tHP
Mode register set cycle time
Data hold skew factor
Max
tHPmin
- tQHS
tCLmin
tWPST
4
ns
or tCHmin
tQHS
DQS write post amble time
Unit Note
0.4
0.5
ns
0.6
tCK
3
Note : 1. Maximum burst refresh of 8
2. The specific requirement is that DQS be valid (High or Low) on or before this CK edge. The
case shown (DQS going from High_Z to logic Low) applies when no writes were previously
in progress on the bus. If a previous write was in progress, DQS could be High at this time,
depending on tDQSS.
3. The maximum limit for this parameter is not a device limit. The device will operate with a
great value for this parameter, but system performance (bus turnaround) will degrade
accordingly.
4. A write command can be applie d with tRCD satisfied after this command.
5. For registered DINNs, tCL and tCH are ≥ 45% of the period including both the half period
jitter (tJIT(HP)) of the PLL and the half period jitter due to cross talk (tJIT(crosstalk)) on the
DIMM.
6. Input Setup/Hold Slew Rate Derating
Input Setup/Hold Slew Rate (V/ns)
∆tIS (ps)
∆tIH (ps)
0.5
0
0
0.4
+50
+50
0.3
+100
+100
This derating table is used to increase tIS /tIH in the case where the input slew rate is below
0.5V/ns. Input setup/hold slew rate based on the lesser of AC-AC slew rate and DC-DC
slew rate.
Kingmax - Memory Module
8
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
7. I/O Setup/Hold Slew Rate Derating
I/O Setup/Hold Slew Rate (V/ns)
∆tIS (ps)
∆Tih (ps)
0.5
0
0
0.4
+75
+75
0.3
+150
+150
This derating table is used to increase tDS /tDH in the case where the I/O slew rate is below
0.5V/ns. I/O setup/hold slew rate based on the lesser of AC-AC slew rate and DC-DC slew
rate.
8. I/O Setup/Hold Plateau Derating
I/O Input Level (mV)
±280
∆tIS (ps)
∆tIH (ps)
+50
+50
This derating table is used to increase tDS /tDH in the case where the input level is flat
below VREF ± 310mV for a duration of up to 2ns.
9. I/O Delta Rise/Fall Rate(1/slew-rate) Derating
Delta Rise/Fall Rate (ns/V)
∆tIS (ps)
∆tIH (ps)
0
0
0
±0.25
+50
+50
±0.5
+100
+100
This derating table is used to increase tDS/tDH in the case where the DQ and DQS slew
rates differ. The Delta Rise/Fall Rate is collated as 1/SlewRate1-1/SlewRate2. For example,
if slew rate 1 = 5V/ns and slew rate 2 =.4V/ns then the Delta Rise/Fall Rate =-0/5ns/V.
Input S/H slew rate based on larger of AC-AC delta rise/fall rate and DC-DC delta rise/fall
rate.
10. This parameter is fir system simulation purpose. It is guaranteed by design.
Input/Output CAPACITANCE
(VDD = 2.5V, TA = 25°C, f = 1MHz, VREF = 1.25V ±100mV)
Pin
Symbol
Min
Max
Unit
Input Capacitance: Command and Address
CIN1
65
81
pF
Input Capacitance: /CS0, /CS1
CIN2
42
50
pF
Input Capacitance: CK0, /CK0, CK1, /CK1
CIN3
42
50
pF
Input Capacitance: CKE0, CKE1
CIN4
27
34
pF
Input/Output Capacitance: DQs, DQS
CI/O
10
13
pF
Kingmax - Memory Module
9
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
COMMAND TRUTH TABLE
Register
Register
Refresh
Command
Extended MRS
Mode Register Set
Auto Refresh
Entry
Self Refresh
Exit
Bank Active & Row Address
Read &
Auto Precharge Disable
Column Address Auto Precharge Enable
Write &
Auto Precharge Disable
Column Address Auto Precharge Enable
Burst Stop
Bank Selection
Precharge
All Banks
Active Power Down
CKEn-1 CKEn /CS /RAS /CAS /WE BA0,1 A10/AP A11,A9~A 0
H
X
L
L
L
L
OP code
H
X
L
L
L
L
OP code
H
H
L
L
L
H
X
L
L
H
H
H
L
H
X
H
X
X
X
H
X
L
L
H
H
V
Row address
Column
L
address
H
X
L
H
L
H
V
(A0~A 9)
H
Column
L
address
H
X
L
H
L
L
V
(A0~A 9)
H
H
H
X
X
Entry
H
L
Exit
L
H
Entry
H
L
Exit
L
H
Precharge Power Down Mode
DM
No operation (NOP) : Not defined
L
H
X
L
L
L
H
L
H
L
X
H
L
H
L
X
V
X
X
H
X
V
X
X
H
X
V
X
X
H
X
V
X
V
X
X
H
X
V
X
H
X
H
H
H
H
H
L
X
V
X
L
H
X
Note
1, 2
1, 2
3
3
3
3
4
4
4
4, 6
7
5
X
X
X
X
8
9
9
(V = Valid, X = Don’t Care, H = Logic High, L = Logic Low)
Note : 1. OP Code : Operand Code. A0 ~ A11 & BA0 ~ BA1 : Program keys. (@EMRS/MRS)
2. EMRS/ MRS can be issued only at all banks precharge state.
A new command can be issued 2 clock cycles after EMRS or MRS.
3. Auto refresh functions are same as the CBR refresh of DRAM.
The automatically precharge without row precharge command is meant by "Auto".
Auto/self refresh can be issued only at all banks precharge state.
4. BA0 ~ BA1 : Bank select addresses.
If both BA0 and BA1 are "Low" at read, write, row active and precharge, bank A is selected.
If both BA0 is "High" and BA1 is "Low" at read, write, row active and precharge, bank B is selected.
If both BA0 is "Low" and BA1 is "High" at read, write, row active and precharge, bank C is selected.
If both BA0 and BA1 are "High" at read, write, row active and precharge, bank D is selected.
5. If A10 /AP is "High" at row precharge, BA0 and BA1 are ignored and all banks are selected.
6. During burst write with auto precharge, new read/write command can not be issued.
Another bank read/write command can be issued after the end of burst.
New row active of the associated bank can be issued at tRP after the end of burst.
7. Burst stop command is valid at every burst length.
8. DM sampled at the rising and falling edges of the DQS and Data-in are masked at the both edges
(Write DM latency is 0).
9. This combination is not defined for any function, which means "No Operation (NOP)" in DDR
SDRAM.
Kingmax - Memory Module
10
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
PACKAGE DIMENSIONS
Units: Millimeter
133.35
131.35
128.95
127.35
1.00
2.20
3.00
1.00
2.20
3.00
B
30.00
U1
17.80
U2
U3
U4
U5
U6
U7
4.0 ±0.1
U8
4.0 ±0.1
10.00
2.30
1
92
53
6.35
64.77
A
77.47
73.295
Ø2.5 ±0.1
1.27 ±0.05
49.53
B'
6.35
60.055
93
145
184
R2.0
R2.0
Ø2.5 ±0.1
R2.0
U9
U10
U11
U12
U13
U14
U15
U16
R2.0
3.81 Max.
6.35
2.175
R 0.9
2.90
1.8 ±0.1
1.0 ±0.05
4.0 Min.
2.50
0.20
4.0 Min.
1.27 ±0.1
Detail A
Section B-B'
Tolerance : ±0.15 unless otherwise specified
The used device is 16Mx8 SDRAM TinyBGA
Kingmax - Memory Module
11
March 2002
Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
SERIAL PRESENCE DETECT INFORMATION
Byte #
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Function described
# of bytes written into serial memory at module manufacturer
Total # of bytes of SPD memory device
Fundamental memory type
# of row address on this assembly
# of column address on this assembly
# of module Rows on this assembly
Data width of this assembly
Data width of this assembly
VDDQ and interface standard of this assembly
DDR SDRAM cycle time from clock @CAS latency of 2.5
DDR SDRAM access time from clock @CAS latency of 2.5
DIMM configuration type (Non-parity , Parity , ECC )
Refresh rate & type
Primary DDR SDRAM width
Error checking DDR SDRAM data width
Minimum clock delay for back-to-back random column
address
DDR SDRAM device attributes: Burst lengths supported
DDR SDRAM device attributes: # of banks on each DDR
SDRAM
devicedevice attributes: CAS Latency supported
DDR
SDRAM
DDR SDRAM device attributes: CS Latency
DDR SDRAM device attributes: WE Latency
21
DDR SDRAM module attributes
22
DDR SDRAM device attributes: General
23
24
25
26
27
28
29
30
31
32
33
34
35
36~61
62
63
DDR SDRAM cycle time @CAS latency of 2
DDR SDRAM access time @CAS latency of 2
SDRAM cycle time @CAS latency of 1.5
SDRAM access time @CAS latency of 1.5
Minimum row precharge time (=tRP)
Minimum row active to row active delay (tRRD)
Minimum RAS to CAS delay (=tRCD)
Minimum activate precharge time (=tRAS)
Module Row density
Command and Address signal input setup time
Command and Address signal input hold time
Data signal input setup time
Data signal input hold time
Superset information (maybe used in future)
SPD data revision code
Checksum for bytes 0 ~ 62
Kingmax - Memory Module
12
Function Supported
128 bytes
256 bytes (2K-bit)
SDRAM DDR
12
10
2 Rows
64 bits
SSTL 2.5V
6.0ns
± 0.7ns
Non-parity , ECC
15.6us, support self refresh
×8
N/A
tCCD=1CLK
2,4,8
4 banks
2 &2.5
0 CLK
1 CLK
Hex value
80h
08h
07h
0Ch
0Ah
02h
40h
00h
04h
60h
70h
00h
80h
08h
00h
01h
0Eh
04h
0Ch
01h
02h
Registered address &
Control inputs and On-card
DLL
20h
+/- 0.2 voltage tolerance
00h
7.5ns
± 0.7ns
18ns
12ns
18ns
42ns
128MB
0.75ns
0.75ns
0.45ns
0.45ns
Initial release
75h
70h
00h
00h
48h
30h
48h
2Ah
20h
75h
75h
45h
45h
00h
00h
E8h
March 2002 Rev: 1.1
MPMB62D-68KX3
256MB PC-2700 DDR DIMM
SERIAL PRESENCE DETECT INFORMATION
64
65
66
67
68~71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95~98
99~125
126
127
Manufacturer JEDEC ID code
Manufacturer JEDEC ID code
Manufacturer JEDEC ID code
Manufacturer JEDEC ID code
Manufacturer JEDEC ID code
Manufacturing location
Manufacturer part # (Memory module)
Manufacturer part # (184 pin DIMM)
Manufacturer part # (DDR 333)
Manufacturer part # (Module density: 256MB)
Manufacturer part # (Module density: 256MB)
Manufacturer part # (Vdd = 2.5V)
Manufacturer part # (DDR SDRAM)
Manufacturer part #
Manufacturer part # (DDR SDRAM type: 16Mb × 8)
Manufacturer part # (DDR SDRAM type: 16Mb × 8)
Manufacturer part # (Kingmax logo)
Manufacturer part # (Kingmax logo)
Manufacturer part # (CL=2.5)
Manufacturer part #
Manufacturer part # (option for die source)
Manufacturer part # (option for module version)
Manufacturer part # (option for die version)
Manufacturer part # (reserve)
Manufacturer revision code (reserve)
Manufacturer revision code (reserve)
Manufacturing date (Work Year) - BCD
Manufacturing date (Work Week) - BCD (reserve)
Assemble serial # -BCD (reserve)
Manufacturer specific data (may be used in future)
Intel specification for frequency
Intel specification details for 100MHz support
128+ Unused storage locations
Kingmax - Memory Module
13
kingmax
kingmax
kingmax
kingmax
Hsin Chu (A)
M
P
M
B
6
2
D
“-“
6
8
K
X
3
“-“
*
*
*
2002
Undefined
7Fh
7Fh
7Fh
25h
00h
41h
4Dh
50h
4Dh
42h
36h
32h
44h
2Dh
36h
38h
4Bh
58h
33h
2Dh
*
*
*
00h
00h
00h
02h
00h
00h
00h