ICS SF0240BA01987S

240 MHz Filter
14 MHz Bandwidth
Part Number
SF0240BA01987S
Micro Networks Corp., 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.icst.com
TYPICAL PERFORMANCE
Horizontal: 10 MHz/div
Vertical (from top): Magnitude 10 dB/div
Magnitude
1 dB/div
Phase
10 deg/div
SPECIFICATION
NOTE – All electrical specifications apply over the whole of the operating temperature range.
Parameter
Center Frequency (Fc)
Insertion Loss at Fc
Amplitude Ripple 1
Amplitude Ripple in any 3.5 MHz interval 1
Rejection (256.5 MHz – 258 MHz) 2
Ultimate Rejection (150 MHz – 224 MHz and
258 MHz – 330 MHz) 2
Phase Linearity 3
Group Delay Ripple 1
Average Delay 1
Triple Travel Suppression
Return Loss at Input and Output 3 4
Input Power
Source and Load Impedance
Operating Temperature Range
Notes:
Min
38
Typ
240
7.7
0.5
0.35
41
40
43
30
9.5
4
40
0.785
40
12
Max
11
1.4
1.0
dB
15
100
1.0
15
50
-40
Units
MHz
dB
dB p-p
dB p-p
dB
+80
deg p-p
ns p-p
µs
dB
dB
dBm
Ω
°C
1. Defined over the pass-band frequency range Fc ± 7 MHz (i.e. 233 MHz to 247 MHz).
2. Attenuation levels (dB) are referenced to the level at Fc.
3. Defined over 90% of the pass-band frequency range (i.e. 233.7 MHz to 246.3 MHz).
4. When matched using external components in MNC test fixture.
Micro Networks Corporation
Worldwide Headquarters: 324 Clark Street Worcester, MA 01606. tel: 508-852-5400 fax: 508-852-8456
www.icst.com
Rev 1.4 30-Apr-04
Page 1 of 2
QF12/2
240 MHz Filter
14 MHz Bandwidth
Part Number
SF0240BA01987S
Micro Networks Corp., 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.icst.com
PACKAGE OUTLINE
Units:
mm
Pin Configuration:
Input:
Input Return
Output:
Output Return
Ground:
10
12
4
6
1,2,3,5,7,8,9,11
MATCHING CIRCUIT
Ls1
Ls2
1
6
Cp1
Cp2
10
Typical component values:
Ls1 = 18 nH
Cp1 = 33 pF
5
Ls2 = 18 nH
Cp2 = 31 pF
Notes:
1. Component values may change depending on board layout. Component values shown are those used in
the Micro Networks test fixture.
2. Recommended maximum component tolerances – inductors 2%, capacitors 1%. Minimum inductor Q=45.
ISO 9001
Registered
Micro Networks Corporation
Worldwide Headquarters: 324 Clark Street Worcester, MA 01606. tel: 508-852-5400 fax: 508-852-8456
www.icst.com
Rev 1.4 30-Apr-04
Page 2 of 2
QF12/2