HYBRID IC M57147AU-01 IPM POWER SUPPLY UNIT OUTLINE DRAWING Lot No M57147AU-01 XXXX 1 18 36 Pin No 19 1.6 33 MAX 82MAX 0.35 0.2 80.35 2.54 0.55 0.1 2.54 17=43 • Electrical isolation (between input and outputs) ........................................................... 1500Vrms 1minute • Electrical isolation (between each outputs) ........................................................... 1500Vrms 1minute (3.41) APPLICATION Power supply for IPM drive BLOCK DIAGRAM 18 Vin+ 16 12 Vin– 19 Vo1+ 20 Vo1– 24 Vo2+ 25 Vo2– 29 Vo3+ 30 Vo3– 34 Vo4+ 17 11 10 35 Vo4– 1 Vo5+ 2 3 4 5 Control circuit Vo6+ Vo5,6 4.5 1.5 FEATURES • Input ................................................... 140 ~ 380VDC • Output ................................................ +15V, 50mAX3 +15V, 150mAX1 +12V, 400mAX1 +5V, 300mAX1 Dimensions: mm 50 0.7 DESCRIPTION The M57147AU-01 is an insulated DC-DC converter designed to drive the IPM. 6 outputs can obtain from an input of 140 ~ 380VDC. The terminals between inputs and outputs, and each outputs are insulated. HYBRID IC M57147AU-01 IPM POWER SUPPLY UNIT MAXIMUM RATINGS (Ta = 25 °C, unless otherwise noted) Symbol Vin Parameter Ratings 380 50 Conditions – Input voltage Vo1, Vo2, Vo3 IL Output current Topr Operating temperature Storage temperature Tstg Po Viso1 Viso2 150 400 Vo4 Vo5 Total output power Electrical isolation between input and outputs Electrical isolation between each outputs Unit V mA Vo6 No condensation 300 –10 ~ 70 °C No condensation –20 ~ 85 *10.8 °C W 1500 1500 Vrms Vrms – Sine wave voltage, 60Hz, 1 minutes Sine wave voltage, 60Hz, 1 minutes *Refer to Output Power vs.Input Voltage Charactreristics ELECTRICAL CHARACTERISTICS (Vin= 140 ~ 380V, Ta = 25 °C, Unless otherwise noted) Symbol Vin Parameter Input voltage Vo1 Recommended range Io1 = 5 ~ 50mA, Io2 = Io3 = 5mA, Io4 = 25mA Io5 = 200mA, Io6 = 200mA Io2 = 5 ~ 50mA, Io1 = Io3 = 5mA, Io4 = 25mA Vo2 Vo3 Test Conditions Output voltage Io5 = 200mA, Io6 = 200mA Io3 = 5 ~ 50mA, Io1 = Io2 = 5mA, Io4= 25mA Io5 = 200mA, Io6 = 200mA Io4 = 25 ~ 150mA, Io1 = Io2 = Io3 = 5mA Vo4 Io5 = 200mA, Io6 = 200mA Io5 = 30 ~ 400mA, Io1 = Io2 = Io3 = 5mA, Io4 = 25mA Vo5 Io6 = 200mA Io6 = 50 ~ 300mA, Io1 = Io2 = Io3 = 5mA, Io4 = 25mA Vo6 Io5 = 200mA Vo1 voltage change Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA, Limits Min. Typ. Max. 140 – 380 14 15 16 14 15 16 14 15 16 14 15 16 11 12 14 4.75 5.0 5.25 – 0.3 0.5 – 0.3 0.5 – 0.3 0.5 Unit V V Io6 = 300mA Vo2 voltage change Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA, Io6 = 300mA Vo3 voltage change Reg-I Line regulation Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA, Io6 = 300mA V Vo4 voltage change Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA, Io6 = 300mA – 0.3 0.5 – 0.2 0.5 – 0.1 0.2 Vo5 voltage change Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA, Io6 = 300mA Vo6 voltage change Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA, Io6 = 300mA HYBRID IC M57147AU-01 IPM POWER SUPPLY UNIT ELECTRICAL CHARACTERISTICS (Vin= 140 ~ 380V, Ta = 25 °C, unless otherwise noted) Symbol Parameter Test Conditions Limits Min. Typ. Max. – 0.4 1.0 Io2 = 5 ~ 50mA, Io1 = Io3 = 50mA, Io4 = 150mA, Io5 = 400mA, Io6 = 300mA, Vin = 300V Vo3 voltage change – 0.4 1.0 Io3 = 5 ~ 50mA, Io1 = Io2 = 50mA, Io4 = 150mA, Io5 = 400mA, Io6 = 300mA, Vin = 300V – 0.4 1.0 Vo1 voltage change Io1 = 5 ~ 50mA, Io2 = Io3 = 50mA, Io4 = 150mA, Unit Io5 = 400mA, Io6 = 300mA, Vin = 300V Vo2 voltage change Reg-L Load regulation Vo4 voltage change Io4 = 25 ~ 150mA, Io1 = Io2 = Io3 = 50mA,, V – 0.5 1.0 – 1.5 1.8 Vo6 voltage change Io6 = 50 ~ 300mA, Io1 = Io2 = Io3 = 50mA, – 0.1 0.2 Io4 =150mA, Io5 = 400mA, Vin = 300V Vin = 300V, Po = 10.8W 70 77 – Io5 = 400mA, Io6 = 300mA, Vin = 300V Vo5 voltage change Io5 = 30 ~ 400mA, Io1 = Io2 = Io3 =50mA, Io4 =150mA, Io6 = 300mA, Vin = 300V Efficiency % HYBRID IC M57147AU-01 IPM POWER SUPPLY UNIT TYPICAL CHARACTERISTICS VO1+ VUP1 + UP VUPC AC200~240V VO1– VO2+ VIN+ VVP1 + + VP VIN– VO2– VVPC VO3+ VWP1 + WP VWPC VO3– VO5+ UN VO6+ VN LOAD LOAD WN IPM F0 VO 5, V VO4+ M57147AU-01 + EX. VN1 PM15/20CT M060(-3) VO4– AVAILABLE IPM EXAMPLES PM100CVA060 PM150CVA060 PM200CVA060 PM75RVA060 PM10CSJ060 PM15CSJ060 PM20CSJ060 PM30CSJ060 PM30RSF060 PM100CSA060 PM150CSA060 PM200CSA060 PM50CTK060 PM75CTK060 PM50RSA060 PM75RSA060 PM100RSA060 PM150RSA060 PM50RSK060 PM75RSK060 PM30CTJ060 PM30CTJ060-3 PM15CTM060 PM15CTM060-3 PM20CTM060 PM20CTM060-3 IHYBRID IC M57147AU-01 IPM POWER SUPPLY UNIT FOR SAFETY USING Great detail and careful attention are given to the production activity of Hics, such as the development, the quality of production, and in it’s reliability. However the reliability of Hics depends not only on their own factors but also in their condition of usage. When handling Hics, please note the following cautions. CAUTIONS Packing Carrying The materials used in packing Hics can only withstand normal external conditions. When exposed to outside shocks, rain and certain environmental contaminators, the packing materials will deteriorates. Please take care in handling. 1) 2) 3) 4) 5) Don’t stack boxes too high. Avoid placing heavy materials on boxes. Boxes must be positioned correctly during transportation to avoid breakage. Don't throw or drop boxes. Keep boxes dry. Avoid rain or snow. Minimal vibration and shock during transportation is desirable. Storage When storing Hics, please observe the following notices or possible deterioration of their electrical characteristics, risk of solder ability, and external damage may occur. 1) Devices must be stored where fluctuation of temperature and humidity is minimal, and must not be exposed to direct sunlight. Store at the normal temperature of 5 to 30 degrees Celsius with humidity at 40 to 60%. 2) Avoid locations where corrosive gasses are generated or where much dust accumulates. 3) Storage cases must be static proof. 4) Avoid putting weight on boxes. Extended storage When extended storage is necessary, Hics must be kept non-processed. When using Hics which have been stored for more than one year or under severe conditions, be sure to check that the exterior is free from flaw and other damages. Maximum ratings To prevent any electrical damages, use Hics within the maximum ratings. The temperature, current, voltage, etc. must not exceed these conditions. Polarity To protect Hics from destruction and deterioration due to wrong insertion, make sure of polarity in inserting leads into the board holes, conforming to the external view for the terminal arrangement. IHYBRID IC M57147AU-01 IPM POWER SUPPLY UNIT Marketing division, Marketing planning department 6-41 Tsukuba, Isahaya, Nagasaki, 854-0065 Japan Keep safety first in your circuit designs! ·ISAHAYA Electronics Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (1) placement of substitutive, auxiliary, (2) use of non-farmable material or (3) prevention against any malfunction or mishap. Notes r egarding these materials ·These materials are intended as a reference to our customers in the selection of the ISAHAYA products best suited to the customer’s application; they don't convey any license under any intellectual property rights, or any other rights, belonging ISAHAYA or third party. ·ISAHAYA Electronics Corporation assumes no responsibility for any damage, or infringement of any third party's rights , originating in the use of any product data, diagrams, charts or circuit application examples contained in these materials. ·All information contained in these materials, including product data, diagrams and charts, represent information on products at the time of publication of these materials, and are subject to change by ISAHAYA Electronics Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact ISAHAYA Electronics Corporation or an authorized ISAHAYA products distributor for the latest product information before purchasing product listed herein. ·ISAHAYA Electronics Corporation products are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact ISAHAYA electronics corporation or an authorized ISAHAYA products distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use. ·The prior written approval of ISAHAYA Electronics Corporation is necessary to reprint or reproduce in whole or in part these materials. ·If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or re-export contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited. ·Please contact ISAHAYA Electronics Corporation or authorized ISAHAYA products distributor for further details on these materials or the products contained therein. Nov.2002