ISAHAYA M57147AU-01

HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
OUTLINE DRAWING
Lot No
M57147AU-01
XXXX
1
18
36
Pin No
19
1.6
33 MAX
82MAX
0.35 0.2
80.35
2.54
0.55 0.1
2.54 17=43
• Electrical isolation (between input and outputs)
........................................................... 1500Vrms 1minute
• Electrical isolation (between each outputs)
........................................................... 1500Vrms 1minute
(3.41)
APPLICATION
Power supply for IPM drive
BLOCK DIAGRAM
18
Vin+
16
12
Vin–
19
Vo1+
20
Vo1–
24
Vo2+
25
Vo2–
29
Vo3+
30
Vo3–
34
Vo4+
17
11
10
35
Vo4–
1
Vo5+
2
3
4
5
Control circuit
Vo6+
Vo5,6
4.5 1.5
FEATURES
• Input ................................................... 140 ~ 380VDC
• Output ................................................ +15V, 50mAX3
+15V, 150mAX1
+12V, 400mAX1
+5V, 300mAX1
Dimensions: mm
50 0.7
DESCRIPTION
The M57147AU-01 is an insulated DC-DC converter designed to drive the IPM. 6 outputs can obtain from an input
of 140 ~ 380VDC.
The terminals between inputs and outputs, and each outputs
are insulated.
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
MAXIMUM RATINGS (Ta = 25 °C, unless otherwise noted)
Symbol
Vin
Parameter
Ratings
380
50
Conditions
–
Input voltage
Vo1, Vo2, Vo3
IL
Output current
Topr
Operating temperature
Storage temperature
Tstg
Po
Viso1
Viso2
150
400
Vo4
Vo5
Total output power
Electrical isolation between input and outputs
Electrical isolation between each outputs
Unit
V
mA
Vo6
No condensation
300
–10 ~ 70
°C
No condensation
–20 ~ 85
*10.8
°C
W
1500
1500
Vrms
Vrms
–
Sine wave voltage, 60Hz, 1 minutes
Sine wave voltage, 60Hz, 1 minutes
*Refer to Output Power vs.Input Voltage Charactreristics
ELECTRICAL CHARACTERISTICS (Vin= 140 ~ 380V, Ta = 25 °C, Unless otherwise noted)
Symbol
Vin
Parameter
Input voltage
Vo1
Recommended range
Io1 = 5 ~ 50mA, Io2 = Io3 = 5mA, Io4 = 25mA
Io5 = 200mA, Io6 = 200mA
Io2 = 5 ~ 50mA, Io1 = Io3 = 5mA, Io4 = 25mA
Vo2
Vo3
Test Conditions
Output voltage
Io5 = 200mA, Io6 = 200mA
Io3 = 5 ~ 50mA, Io1 = Io2 = 5mA, Io4= 25mA
Io5 = 200mA, Io6 = 200mA
Io4 = 25 ~ 150mA, Io1 = Io2 = Io3 = 5mA
Vo4
Io5 = 200mA, Io6 = 200mA
Io5 = 30 ~ 400mA, Io1 = Io2 = Io3 = 5mA, Io4 = 25mA
Vo5
Io6 = 200mA
Io6 = 50 ~ 300mA, Io1 = Io2 = Io3 = 5mA, Io4 = 25mA
Vo6
Io5 = 200mA
Vo1 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Limits
Min.
Typ.
Max.
140
–
380
14
15
16
14
15
16
14
15
16
14
15
16
11
12
14
4.75
5.0
5.25
–
0.3
0.5
–
0.3
0.5
–
0.3
0.5
Unit
V
V
Io6 = 300mA
Vo2 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo3 voltage change
Reg-I
Line regulation
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
V
Vo4 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
–
0.3
0.5
–
0.2
0.5
–
0.1
0.2
Vo5 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo6 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
ELECTRICAL CHARACTERISTICS (Vin= 140 ~ 380V, Ta = 25 °C, unless otherwise noted)
Symbol
Parameter
Test Conditions
Limits
Min.
Typ.
Max.
–
0.4
1.0
Io2 = 5 ~ 50mA, Io1 = Io3 = 50mA, Io4 = 150mA,
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo3 voltage change
–
0.4
1.0
Io3 = 5 ~ 50mA, Io1 = Io2 = 50mA, Io4 = 150mA,
Io5 = 400mA, Io6 = 300mA, Vin = 300V
–
0.4
1.0
Vo1 voltage change
Io1 = 5 ~ 50mA, Io2 = Io3 = 50mA, Io4 = 150mA,
Unit
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo2 voltage change
Reg-L
Load regulation
Vo4 voltage change
Io4 = 25 ~ 150mA, Io1 = Io2 = Io3 = 50mA,,
V
–
0.5
1.0
–
1.5
1.8
Vo6 voltage change
Io6 = 50 ~ 300mA, Io1 = Io2 = Io3 = 50mA,
–
0.1
0.2
Io4 =150mA, Io5 = 400mA, Vin = 300V
Vin = 300V, Po = 10.8W
70
77
–
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo5 voltage change
Io5 = 30 ~ 400mA, Io1 = Io2 = Io3 =50mA,
Io4 =150mA, Io6 = 300mA, Vin = 300V
Efficiency
%
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
TYPICAL CHARACTERISTICS
VO1+
VUP1
+
UP
VUPC
AC200~240V
VO1–
VO2+
VIN+
VVP1
+
+
VP
VIN–
VO2–
VVPC
VO3+
VWP1
+
WP
VWPC
VO3–
VO5+
UN
VO6+
VN
LOAD
LOAD
WN
IPM
F0
VO 5, V
VO4+
M57147AU-01
+
EX.
VN1 PM15/20CT
M060(-3)
VO4–
AVAILABLE IPM EXAMPLES
PM100CVA060
PM150CVA060
PM200CVA060
PM75RVA060
PM10CSJ060
PM15CSJ060
PM20CSJ060
PM30CSJ060
PM30RSF060
PM100CSA060
PM150CSA060
PM200CSA060
PM50CTK060
PM75CTK060
PM50RSA060
PM75RSA060
PM100RSA060
PM150RSA060
PM50RSK060
PM75RSK060
PM30CTJ060
PM30CTJ060-3
PM15CTM060
PM15CTM060-3
PM20CTM060
PM20CTM060-3
IHYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
FOR SAFETY USING
Great detail and careful attention are given to the production activity of Hics, such as the development, the quality of production,
and in it’s reliability. However the reliability of Hics depends not only on their own factors but also in their condition of usage.
When handling Hics, please note the following cautions.
CAUTIONS
Packing
Carrying
The materials used in packing Hics can only withstand normal external conditions.
When exposed to outside shocks, rain and certain environmental contaminators, the packing materials
will deteriorates. Please take care in handling.
1)
2)
3)
4)
5)
Don’t stack boxes too high. Avoid placing heavy materials on boxes.
Boxes must be positioned correctly during transportation to avoid breakage.
Don't throw or drop boxes.
Keep boxes dry. Avoid rain or snow.
Minimal vibration and shock during transportation is desirable.
Storage
When storing Hics, please observe the following notices or possible deterioration of their electrical
characteristics, risk of solder ability, and external damage may occur.
1) Devices must be stored where fluctuation of temperature and humidity is minimal, and must not
be exposed to direct sunlight. Store at the normal temperature of 5 to 30 degrees Celsius with
humidity at 40 to 60%.
2) Avoid locations where corrosive gasses are generated or where much dust accumulates.
3) Storage cases must be static proof.
4) Avoid putting weight on boxes.
Extended storage
When extended storage is necessary, Hics must be kept non-processed. When using Hics which
have been stored for more than one year or under severe conditions, be sure to check that the exterior
is free from flaw and other damages.
Maximum ratings
To prevent any electrical damages, use Hics within the maximum ratings. The temperature, current,
voltage, etc. must not exceed these conditions.
Polarity
To protect Hics from destruction and deterioration due to wrong insertion, make sure of polarity in
inserting leads into the board holes, conforming to the external view for the terminal arrangement.
IHYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
Marketing division, Marketing planning department
6-41 Tsukuba, Isahaya, Nagasaki, 854-0065 Japan
Keep safety first in your circuit designs!
·ISAHAYA Electronics Corporation puts the maximum effort into making semiconductor products better and more reliable, but
there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or
property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures
such as (1) placement of substitutive, auxiliary, (2) use of non-farmable material or (3) prevention against any malfunction or
mishap.
Notes r egarding these materials
·These materials are intended as a reference to our customers in the selection of the ISAHAYA products best suited to the
customer’s application; they don't convey any license under any intellectual property rights, or any other rights, belonging
ISAHAYA or third party.
·ISAHAYA Electronics Corporation assumes no responsibility for any damage, or infringement of any third party's rights ,
originating in the use of any product data, diagrams, charts or circuit application examples contained in these materials.
·All information contained in these materials, including product data, diagrams and charts, represent information on products
at the time of publication of these materials, and are subject to change by ISAHAYA Electronics Corporation without notice
due to product improvements or other reasons. It is therefore recommended that customers contact ISAHAYA Electronics
Corporation or an authorized ISAHAYA products distributor for the latest product information before purchasing product listed
herein.
·ISAHAYA Electronics Corporation products are not designed or manufactured for use in a device or system that is used
under circumstances in which human life is potentially at stake. Please contact ISAHAYA electronics corporation or an
authorized ISAHAYA products distributor when considering the use of a product contained herein for any specific purposes,
such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
·The prior written approval of ISAHAYA Electronics Corporation is necessary to reprint or reproduce in whole or in part these
materials.
·If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a
license from the Japanese government and cannot be imported into a country other than the approved destination. Any
diversion or re-export contrary to the export control laws and regulations of Japan and/or the country of destination is
prohibited.
·Please contact ISAHAYA Electronics Corporation or authorized ISAHAYA products distributor for further details on these
materials or the products contained therein.
Nov.2002