ISSI IS24C02B-2GI

ISSI
®
IS24C01B IS24C02B
1K-bit/2K-bit
2-WIRE SERIAL CMOS EEPROM
APRIL 2006
FEATURES
DESCRIPTION
• Two-Wire Serial Interface, I2CTM compatible
–Bi-directional data transfer protocol
• Wide Voltage Operation
–Vcc = 1.8V to 5.5V
• 400 KHz (2.5V) and 1 MHz (5.0V) compatibility
• Low Power CMOS Technology
–Standby Current less than 6 µA (5.0V)
–Read Current less than 2 mA (5.0V)
–Write Current less than 3 mA (5.0V)
• Hardware Data Protection
–Write Protect Pin
• Sequential Read Feature
• Filtered Inputs for Noise Suppression
• Self time write cycle with auto clear
5 ms max. @ 2.5V
• Organization:
–IS24C01B 128x8 (128 bytes)
–IS24C02B 256x8 (256 bytes)
• 8 Byte Page Write Buffer
• High Reliability
–Endurance: 1,000,000 Cycles
–Data Retention: 100 Years
• Industrial and Automotive temperature ranges
• 8-pin PDIP, 8-pin SOIC, 8-pad DFN, and 8-pin
TSSOP packages
• Lead-free available
The IS24C01B and IS24C02B are electrically
erasable PROM devices that use the standard 2wire interface for communications. The IS24C01B
and IS24C02B contain a memory array of 1K-bits
(128 x 8) and 2K-bits (256 x 8), respectively. Each
device is organized into 8 byte pages for page
write mode.
This EEPROM operates in a wide voltage range of
1.8V to 5.5V to be compatible with most application
voltages. ISSI designed this device family to be a
practical, low-power 2-wire EEPROM solution.
The devices are available in 8-pin PDIP, 8-pin
SOIC, 8-pad DFN, and 8-pin TSSOP packages.
The IS24C01B/02B maintains compatibility with
the popular 2-wire bus protocol, so it is easy to
use in applications implementing this bus type.
The simple bus consists of the Serial Clock wire
(SCL) and the Serial Data wire (SDA). Using the
bus, a Master device such as a microcontroller is
usually connected to one or more Slave devices
such as this device. The bit stream over the SDA
line includes a series of bytes, which identifies a
particular Slave device, an instruction, an address
within that Slave device, and a series of data, if
appropriate. The IS24C01B/02B has a
Write Protect pin (WP) to allow blocking of any
write instruction transmitted over the bus.
Copyright © 2006 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time
without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to
obtain the latest version of this device specification before relying on any published information and before placing orders for products.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
1
IS24C01B
ISSI
IS24C02B
®
FUNCTIONAL BLOCK DIAGRAM
HIGH VOLTAGE
GENERATOR,
TIMING & CONTROL
8
SDA
5
SCL
6
WP
7
CONTROL
LOGIC
SLAVE ADDRESS
REGISTER &
COMPARATOR
A0
1
A1
2
A2
3
GND
4
EEPROM
ARRAY
WORD ADDRESS
COUNTER
ACK
nMOS
2
X
DECODER
Vcc
Y
DECODER
Clock
DI/O
>
DATA
REGISTER
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
®
PIN CONFIGURATION
8-pad DFN
8-Pin DIP, SOIC, TSSOP
A0
1
8
VCC
A1
2
7
WP
A2
3
6
SCL
GND
4
5
SDA
A0 1
8 VCC
A1 2
7 WP
A2 3
6 SCL
GND 4
5 SDA
(Top View)
PIN DESCRIPTIONS
A0-A2
Address Inputs
SDA
Serial Address/Data I/O
SCL
Serial Clock Input
WP
Write Protect Input
Vcc
Power Supply
GND
Ground
SCL
This input clock pin is used to synchronize the data transfer
to and from the device.
SDA
The SDA is a Bi-directional pin used to transfer addresses and
data into and out of the device. The SDA pin is an open drain
output and can be wire-Or'ed with other open drain or open
collector outputs. The SDA bus requires a pullup resistor to
Vcc.
A0, A1, A2
The A0, A1 and A2 are the device address inputs. The
IS24C01B/02B uses the A0, A1, and A2 for hardware addressing
and a total of 8 devices may be used on a single bus system.
When the A0, A1, or A2 inputs are left floating, the input
internally defaults to zero.
WP
WP is the Write Protect pin. If the WP pin is tied to VCC on the
EEPROM, the entire array becomes Write Protected (Read
only). When WP is tied to GND or left floating normal read/
write operations are allowed to the device.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
3
IS24C01B
ISSI
IS24C02B
®
DEVICE OPERATION
Stop Condition
IS24C01B/02B features serial communication and supports
a bi-directional 2-wire bus transmission protocol called I2CTM.
The Stop condition is defined as a Low to High transition
of SDA when SCL is High. All operations must end with
a Stop condition.
2-WIRE BUS
Acknowledge (ACK)
The two-wire bus is defined as a Serial Data line (SDA), and
a Serial Clock line (SCL). The protocol defines any device that
sends data onto the SDA bus as a transmitter, and the
receiving devices as receivers. The bus is controlled by
Master device that generates the SCL, controls the bus
access, and generates the Stop and Start conditions. The
IS24C01B/02B is the Slave device on the bus.
The Bus Protocol:
– Data transfer may be initiated only when the bus is not busy
– During a data transfer, the SDA line must remain stable
whenever the SCL line is high. Any changes in the SDA
line while the SCL line is high will be interpreted as a Start
or Stop condition.
The state of the SDA line represents valid data after a Start
condition. The SDA line must be stable for the duration of the
High period of the clock signal. The data on the SDA line may
be changed during the Low period of the clock signal. There
is one clock pulse per bit of data. Each data transfer is
initiated with a Start condition and terminated with a Stop
condition.
After a successful data transfer, each receiving device is
required to generate an ACK. The Acknowledging device
pulls down the SDA line.
Reset
The IS24C01B/02B contains a reset function in case
the 2-wire bus transmission is accidentally interrupted
(eg. a power loss), or needs to be terminated midstream. The reset is caused when the Master device
creates a Start condition. To do this, it may be
necessary for the Master device to monitor the SDA
line while cycling the SCL up to nine times. (For each
clock signal transition to High, the Master checks for a
High level on SDA.)
Standby Mode
Power consumption is reduced in standby mode. The
IS24C01B/02B will enter standby mode: a) At Power-up,
and remain in it until SCL or SDA toggles; b) Following
the Stop signal if a no write operation is initiated; or c)
Following any internal write operation.
Start Condition
The Start condition precedes all commands to the device and
is defined as a High to Low transition of SDA when SCL is High.
The EEPROM monitors the SDA and SCL lines and will not
respond until the Start condition is met.
4
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
DEVICE ADDRESSING
WRITE OPERATION
The Master begins a transmission by sending a Start
condition. The Master then sends the address of the
particular Slave devices it is requesting. The Slave device
(Fig. 5) address is 8 bits.
Byte Write
The four most significant bits of the Slave device address
are fixed as 1010 for the IS24C01B/02B.
The next three bits of the Slave address are specific for
each of the EEPROM. The bit values enable access to
multiple memory blocks or multiple devices.
The IS24C01B/02B uses the three bits A0, A1, and A2 in
a comparison with the hard-wired input values on the A0,
A1, and A2 pins. Up to eight units may share the 2-wire
bus.
The last bit of the Slave address specifies whether a Read
or Write operation is to be performed. When this bit is set
to 1, a Read operation is selected, and when set to 0, a Write
operation is selected.
After the Master transmits the Start condition and Slave
address byte (Fig. 5), the appropriate 2-wire Slave
(eg.IS24C02B) will respond with ACK on the SDA line. The
Slave will pull down the SDA on the ninth clock cycle,
signaling that it received the eight bits of data. The selected
EEPROM then prepares for a Read or Write operation by
monitoring the bus.
®
In the Byte Write mode, the Master device sends the Start
condition and the Slave address information (with the R/W
set to Zero) to the Slave device. After the Slave generates
an ACK, the Master sends the byte address that is to be
written into the address pointer of the IS24C01B/02B. After
receiving another ACK from the Slave, the Master device
transmits the data byte to be written into the address
memory location. The IS24C01B/02B acknowledges once
more and the Master generates the Stop condition, at
which time the device begins its internal programming
cycle. While this internal cycle is in progress, the device
will not respond to any request from the Master device.
Page Write
The IS24C01B/02B is capable of 8-byte Page-Write
operation. A Page-Write is initiated in the same manner as
a Byte Write, but instead of terminating the internal Write
cycle after the first data word is transferred, the Master
device can transmit up to 7 more bytes. After the receipt of
each data word, the EEPROM responds immediately with an
ACK on SDA line, and the three lower order data word
address bits are internally incremented by one, while the
higher order bits of the data word address remain constant.
If a byte address is incremented from the last byte of a
page, it returns to the first byte of that page. If the Master
device should transmit more than 8 bytes prior to issuing the
Stop condition, the address counter will “roll over,” and the
previously written data will be overwritten. Once all 8 bytes
are received and the Stop condition has been sent by the
Master, the internal programming cycle begins. At this point,
all received data is written to the IS24C01B/02B in a single
Write cycle. All inputs are disabled until completion of the
internal Write cycle.
Acknowledge (ACK) Polling
The disabling of the inputs can be used to take advantage of
the typical Write cycle time. Once the Stop condition is
issued to indicate the end of the host's Write operation, the
IS24C01B/02B initiates the internal Write cycle. ACK polling
can be initiated immediately. This involves issuing the
Start condition followed by the Slave address for a Write
operation. If the EEPROM is still busy with the Write
operation, no ACK will be returned. If the IS24C01B/02B
has completed the Write operation, an ACK will be returned
and the host can then proceed with the next Read or Write
operation.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
5
IS24C01B
ISSI
IS24C02B
®
READ OPERATION
Random Address Read
Read operations are initiated in the same manner as Write
operations, except that the (R/W) bit of the Slave address
is set to “1”. There are three Read operation options:
current address read, random address read and sequential
read.
Selective Read operations allow the Master device to
select at random any memory location for a Read
operation. The Master device first performs a 'dummy'
Write operation by sending the Start condition, Slave
address and byte address of the location it wishes to read.
After the IS24C01B/02B acknowledges the byte address,
the Master device resends the Start condition and the
Slave address, this time with the R/W bit set to one. The
EEPROM then responds with its ACK and sends the data
requested. The Master device does not send an ACK but
will generate a Stop condition. (Refer to Figure 9. Random
Address Read Diagram.)
Current Address Read
The IS24C01B/02B contains an internal address counter
which maintains the address of the last byte accessed,
incremented by one. For example, if the previous operation
is either a Read or Write operation addressed to the
address location n, the internal address counter would
increment to address location n+1. When the EEPROM
receives the Slave Addressing Byte with a Read operation
(R/W bit set to “1”), it will respond an ACK and transmit the
8-bit data byte stored at address location n+1. The Master
should not acknowledge the transfer but should generate
a Stop condition so the IS24C01B/02B discontinues
transmission. If 'n' is the last byte of the memory, the data
from location '0' will be transmitted. (Refer to Figure 8.
Current Address Read Diagram.)
Sequential Read
Sequential Reads can be initiated as either a Current
Address Read or Random Address Read. After the
IS24C01B/02B sends the initial byte sequence, the Master
device now responds with an ACK, indicating it requires
additional data from the IS24C01B/02B. The EEPROM
continues to output data for each ACK received. The
Master device terminates the sequential Read operation
by pulling SDA High (no ACK) indicating the last data word
to be read, followed by a Stop condition.
The data output is sequential, with the data from address
n followed by the data from address n+1,n+2 ... etc. The
address counter increments by one automatically, allowing
the entire memory contents to be serially read during
sequential Read operation. When the memory address
boundary of 127 or 255 (depending on the device) is
reached, the address counter “rolls over” to address 0, and
the device continues to output data. (Refer to Figure 10.
Sequential Read Diagram).
6
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
®
FIGURE 1. TYPICAL SYSTEM BUS CONFIGURATION
Vcc
SDA
SCL
Master
Transmitter/
Receiver
IS24Cxx
FIGURE 2. OUTPUT ACKNOWLEDGE
SCL from
Master
1
8
9
Data Output
from
Transmitter
tAA
Data Output
from
Receiver
tAA
ACK
STOP
Condition
SCL
START
Condition
FIGURE 3. START AND STOP CONDITIONS
SDA
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
7
IS24C01B
ISSI
IS24C02B
®
FIGURE 4. DATA VALIDITY PROTOCOL
Data Change
SCL
Data Stable
Data Stable
SDA
FIGURE 5. SLAVE ADDRESS
BIT
7
6
5
4
3
2
1
0
1
0
1
0
A2
A1
A0
R/W
FIGURE 6. BYTE WRITE
SDA
Bus
Activity
S
T
A
R
T
Device
Address
W
R
I
T
E
M
S
B
Data
Byte Address
A
C
K
*
S
T
O
P
A
C
K
A
C
K
L
M
S
S
B
B
R/W
* = Don't care bit for IS24C01B
8
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
®
FIGURE 7. PAGE WRITE
SDA
Bus
Activity
S
T
A
R
T
W
R
I
T
E
Device
Address
M
S
B
Data (n)
Byte Address (n)
A
C
K
Data (n+1)
A
C
K
*
A
C
K
S
T
O
P
Data (n+7)
A
C
K
A
C
K
L
S
B
R/W
* = Don't care bit for IS24C01B
FIGURE 8. CURRENT ADDRESS READ
S
T
A
R
T
R
E
A
D
Device
Address
SDA
Bus
Activity
S
T
O
P
Data
A
C
K
M
S
B
L
S
B
N
O
A
C
K
R/W
FIGURE 9. RANDOM ADDRESS READ
S
T
A
R
T
Device
Address
SDA
Bus
Activity
W
R
I
T
E
Byte
Address (n)
A
C
K
M
S
B
S
T
A
R
T
*
Device
Address
A
C
K
L
S
B
R/W
R
E
A
D
S
T
O
P
Data n
A
C
K
N
O
A
C
K
DUMMY WRITE
* = Don't care bit for IS24C01B
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
9
IS24C01B
ISSI
IS24C02B
®
FIGURE 10. SEQUENTIAL READ
Device
Address
SDA
Bus
Activity
R
E
A
D
Data Byte n
A
C
K
Data Byte n+1
A
C
K
Data Byte n+2
A
C
K
S
T
O
P
Data Byte n+X
A
C
K
N
O
R/W
10
A
C
K
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
®
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
VS
VP
TBIAS
TSTG
IOUT
Parameter
Supply Voltage
Voltage on Any Pin
Temperature Under Bias
Storage Temperature
Output Current
Value
–0.5 to +6.5
–0.5 to Vcc + 0.5
–55 to +125
–65 to +150
5
Unit
V
V
°C
°C
mA
Notes:
1. Stress greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation of the
device at these or any other conditions above those indicated in the operational sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect reliability.
OPERATING RANGE
(IS24C01B-2 & IS24C02B-2)
Range
Industrial
Ambient Temperature
–40°C to +85°C
VCC
1.8V to 5.5V
Note:
ISSI offers Industrial grade for Commercial applications (0oC to +70oC).
OPERATING RANGE
(IS24C01B-3 & IS24C02B-3)
Range
Automotive
Ambient Temperature
–40°C to +125°C
VCC
2.5V to 5.5V
CAPACITANCE(1,2)
Symbol
CIN
COUT
Parameter
Input Capacitance
Output Capacitance
Conditions
VIN = 0V
VOUT = 0V
Max.
6
8
Unit
pF
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: TA = 25°C, f = 1 MHz, Vcc = 5.0V.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
11
IS24C01B
ISSI
IS24C02B
®
AC WAVEFORMS
Figure 11. Bus Timing
tR
tF
tHIGH
tLOW
tSU:STO
SCL
tSU:STA
tBUF
tHD:DAT
tHD:STA
tSU:DAT
SDAIN
tAA
tDH
SDAOUT
tSU:WP
tHD:WP
WP
Figure 12. Write Cycle Timing
SCL
SDA
8th BIT
ACK
tWR
WORD n
STOP
Condition
12
START
Condition
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
®
DC ELECTRICAL CHARACTERISTICS
Industrial (TA = -40oC to +85oC), Automotive (TA = -40oC to +125oC)
Symbol
VOL1
VOL2
VIH
V IL
I LI
ILO
Parameter
Output Low Voltage
Output Low Voltage
Input High Voltage
Input Low Voltage
Input Leakage Current
Output Leakage Current
Test Conditions
VCC = 1.8V, IOL = 0.15 mA
VCC = 2.5V, IOL = 3 mA
Min.
Max.
—
0.2
—
0.4
VCC X 0.7 VCC + 0.5
–1.0
VCC X 0.3
—
3
—
3
VIN = VCC max.
Unit
V
V
V
V
µA
µA
Notes: VIL min and VIH max are reference only and are not tested.
POWER SUPPLY CHARACTERISTICS
Industrial (TA = -40oC to +85oC), Automotive (TA = -40oC to +125oC)
Symbol
ICC1
ICC2
ISB1
ISB2
Parameter
Vcc Operating Current
Vcc Operating Current
Standby Current
Standby Current
Test Conditions
Read at 400 KHz (Vcc = 5V)
Write at 400 KHz (Vcc = 5V)
Vcc = 1.8V
Vcc = 2.5V
ISB3
Standby Current
Vcc = 5.0V
Min.
—
—
—
—
Max.
2.0
3.0
1
2
Unit
mA
mA
µA
µA
—
6
µA
AC ELECTRICAL CHARACTERISTICS
Industrial (TA = -40oC to +85oC)
Symbol
fSCL
T
tLow
tHigh
tBUF
tSU:STA
tSU:STO
tHD:STA
tHD:STO
tSU:DAT
tHD:DAT
tSU:WP
tHD:WP
tDH
tAA
tR
tF
tWR
1.8V ≤ Vcc < 2.5V
Parameter
Min.
Max.
SCL Clock Frequency
0
100
(1)
Noise Suppression Time
—
100
Clock Low Period
4.7
—
Clock High Period
4
—
Bus Free Time Before New Transmission(1) 4.7
—
Start Condition Setup Time
4
—
Stop Condition Setup Time
4
—
Start Condition Hold Time
4
—
Stop Condition Hold Time
4
—
Data In Setup Time
100
—
Data In Hold Time
0
—
WP pin Setup Time
4
—
WP pin Hold Time
4.7
—
Data Out Hold Time
100
—
(SCL Low to SDA Data Out Change)
Clock to Output
100
3500
(SCL Low to SDA Data Out Valid)
SCL and SDA Rise Time(1)
—
1000
SCL and SDA Fall Time(1)
—
300
Write Cycle Time
—
10
2.5V ≤ Vcc < 4.5V
Min.
Max.
0
400
—
50
1.2
—
0.6
—
1.2
—
0.6
—
0.6
—
0.6
—
0.6
—
100
—
0
—
0.6
—
1.2
—
50
—
4.5V ≤ Vcc ≤ 5.5V(1)
Min. Max.
Unit
0
1000
KHz
—
50
ns
0.6
—
µs
0.4
—
µs
0.5
—
µs
0.25
—
µs
0.25
—
µs
0.25
—
µs
0.25
—
µs
100
—
ns
0
—
ns
0.6
—
µs
1.2
—
µs
50
—
ns
50
900
50
400
ns
—
—
—
300
300
5
—
—
—
300
100
5
ns
ns
ms
Note:
1. This parameter is characterized but not 100% tested.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
13
IS24C01B
ISSI
IS24C02B
®
AC ELECTRICAL CHARACTERISTICS
Automotive (TA = -40oC to +125oC)
2.5V ≤ Vcc < 4.5V
Symbol Parameter
Min. Max.
4.5V ≤ Vcc ≤ 5.5V(1)
Min.
Max.
Unit
fSCL
SCL Clock Frequency
0
400
0
1000
KHz
T
Noise Suppression Time(1)
—
50
—
50
ns
tLow
Clock Low Period
1.2
—
0.6
—
µs
tHigh
Clock High Period
0.6
—
0.4
—
µs
Transmission(1)
tBUF
Bus Free Time Before New
1.2
—
0.5
—
µs
tSU:STA
Start Condition Setup Time
0.6
—
0.25
—
µs
tSU:STO
Stop Condition Setup Time
0.6
—
0.25
—
µs
tHD:STA
Start Condition Hold Time
0.6
—
0.25
—
µs
tHD:STO
Stop Condition Hold Time
0.6
—
0.25
—
µs
tSU:DAT
Data In Setup Time
100
—
100
—
ns
tHD:DAT
Data In Hold Time
0
—
0
—
ns
tSU:WP
WP pin Setup Time
0.6
—
0.6
—
µs
tHD:WP
WP pin Hold Time
1.2
—
1.2
—
µs
tDH
Data Out Hold Time (SCL Low to SDA Data Out Change)
50
—
50
—
ns
tAA
Clock to Output (SCL Low to SDA Data Out Valid)
50
900
50
550
ns
—
300
—
300
ns
—
300
—
100
ns
—
10
—
5
ms
tR
SCL and SDA Rise
tF
SCL and SDA Fall
tWR
Write Cycle Time
Time(1)
Time(1)
Note:
1. This parameter is characterized but not 100% tested.
14
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
IS24C01B
ISSI
IS24C02B
®
ORDERING INFORMATION
Industrial Range: –40°C to +85°C
Voltage
Range
Part Number
Package
1.8V
to 5.5V
IS24C01B-2PI
IS24C01B-2GI
IS24C01B-2ZI
300-mil Plastic DIP
Small Outline (JEDEC STD)
TSSOP
1.8V
to 5.5V
IS24C02B-2PI
IS24C02B-2GI
IS24C02B-2ZI
300-mil Plastic DIP
Small Outline (JEDEC STD)
TSSOP
ORDERING INFORMATION
Industrial Range: –40°C to +85°C, Lead-free
Voltage
Range
Part Number
Package
1.8V
to 5.5V
IS24C01B-2PLI
IS24C01B-2GLI
IS24C01B-2ZLI
300-mil Plastic DIP
Small Outline (JEDEC STD)
TSSOP
1.8V
to 5.5V
IS24C02B-2PLI
IS24C02B-2GLI
IS24C02B-2ZLI
IS24C02B-2DLI
300-mil Plastic DIP
Small Outline (JEDEC STD)
TSSOP
DFN (2mm x 3mm)
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. A
04/12/06
15
ISSI
PACKAGING INFORMATION
®
300-mil Plastic DIP
Package Code: N,P
N
E1
1
D
S
S
SEATING PLANE
B1
E
A
L
C
A1
FOR
32-PIN ONLY
e
MILLIMETERS
Sym.
Min.
INCHES
Max.
Min.
Max.
4.57
9.53
8.26
0.145
0.015
0.014
0.045
0.032
0.008
0.359
0.300
0.180
E
3.68
0.38
0.36
1.14
0.81
0.20
9.12
7.62
E1
6.20
6.60
0.244
0.260
eA
e
8.13
9.65
0.320
0.380
L
3.18
—
0.125
—
S
0.64
0.762
0.025
0.030
N0.
Leads
A
A1
B
B1
B2
C
D
B2
B
eA
Notes:
1. Controlling dimension: inches, unless otherwise specified.
2. BSC = Basic lead spacing between centers.
3. Dimensions D and E1 do not include mold flash protrusions and should
be measured from the bottom of the package.
4. Formed leads shall be planar with respect to one another within 0.004
inches at the seating plane.
8
—
0.56
1.52
1.17
0.33
2.54 BSC
—
0.022
0.060
0.046
0.013
0.375
0.325
0.100 BSC
Copyright © 2003 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time
without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to
obtain the latest version of this device specification before relying on any published information and before placing orders for products.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. D
02/14/03
ISSI
PACKAGING INFORMATION
150-mil Plastic SOP
Package Code: G, GR
®
N
E
H
1
D
SEATING PLANE
A
A1
e
L
α
C
B
Symbol
Ref. Std.
No. Leads
A
A1
B
C
D
E
H
e
L
150-mil Plastic SOP (G, GR)
Min
Max
Min
Max
Inches
mm
8
8
—
0.068
—
1.73
0.004
0.009
0.1
0.23
0.013
0.020
0.33
0.51
0.007
0.010
0.18
0.25
0.189
0.197
4.8
5
0.150
0.157
3.81
3.99
0.228
0.245
5.79
6.22
0.050 BSC
1.27 BSC
0.020
0.035
0.51
0.89
Notes:
1. Controlling dimension: inches, unless otherwise specified.
2. BSC = Basic lead spacing between centers.
3. Dimensions D and E1 do not include mold flash protrusions and should be
measured from the bottom of the package.
4. Formed leads shall be planar with respect to one another within 0.004 inches at the
seating plane.
Integrated Silicon Solution, Inc. — 1-800-379-4774
Rev. C
10/03/01
2
ISSI
PACKAGING INFORMATION
®
Dual Flat No-Lead
Package Code: D (8-pad)
D2
E
tie bars(3)
b
(8X)
E2
A
Pad 1 ID
L (8X)
D
A2
A1
e (6X)
1.50 REF.
A3
Pad 1 index area
DFN
MILLIMETERS
Sym.
Min. Nom. Max.
N0.
Pad
8
D
2.00 BSC
E
3.00 BSC
D2
1.50
—
1.75
E2
1.60
—
1.90
A
0.70
0.75
0.80
A1
0.0
0.02
0.05
A2
—
—
0.75
A3
L
0.20 REF
0.30
e
b
Notes:
1. Refer to JEDEC Drawing MO-229.
2. This is the metallized terminal and
is measured between 0.18 mm
and 0.30 mm from the terminal tip.
The terminal may have a straight
end instead of rounded.
3. Package may have exposed tie
bars, ending flush with package
edge.
0.40
0.50
0.50 BSC
0.18
0.25
0.30
Copyright © 2006 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time
without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to
obtain the latest version of this device specification before relying on any published information and before placing orders for products.
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
Rev. B
02/13/06
ISSI
PACKAGING INFORMATION
Thin Shrink Small Outline TSSOP
Package Code: Z (8 pin, 14 pin)
N
E1
1
E
α
N/2
A1
D
A2
A
L
C
e
B
TSSOP (Z)
Ref. Std.
JEDEC MO-153
No. Leads
8
Millimeters
Inches
Symbol Min Max
Min Max
A
—
1.20
— 0.047
A1
0.05 0.15
0.002 0.006
A2
0.80 1.05
0.032 0.041
B
0.19 0.30
0.007 0.012
C
0.09 0.20
0.004 0.008
D
2.90 3.10
0.114 0.122
E1
4.30 4.50
0.169 0.177
E
6.40 BSC
0.252 BSC
e
0.65 BSC
0.026 BSC
L
0.45 0.75
0.018 0.030
α
—
8°
—
8°
TSSOP (Z)
Ref. Std.
JEDEC MO-153
No. Leads
14
Millimeters
Inches
Symbol Min Max
Min
Max
A
—
1.20
—
0.047
A1
0.05 0.15
0.002 0.006
A2
0.80 1.05
0.031 0.041
B
0.19 0.30
0.007 0.012
C
0.09 0.20
0.0035 0.008
D
4.90 5.10
0.193 0.201
E1
4.30 4.50
0.170 0.177
E
6.40 BSC
0.252 BSC
e
0.65 BSC
0.026 BSC
L
0.45 0.75
0.0177 0.0295
α
—
8°
—
8°
SSI reserves the right to make changes to its products at any time without notice in order to improve design and supply the best possible product. We assume no responsibility for any errors which may
appear in this publication. © Copyright 2002, Integrated Silicon Solution, Inc.
Integrated Silicon Solution, Inc.
Rev B 02/01/02
®